Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 134 for “"defibrillation"”.

  1. New Paradigm of Defibrillation: Towards Painless Therapy

    … atrial tachyarrhythmias and the mechanisms of defibrillation using the conventional high-voltage single shock. Through the use of novel fluorescent optical mapping techniques and several animal models of ventricular and atrial arrhythmias, we develop and validate several novel low-voltage …

    wustl Repository record for New Paradigm of Defibrillation: Towards Painless Therapy (opens in a new tab)

  2. Ventricular fibrillation in ischaemia and its defibrillation

    … epicardial surface. In contrast, minimum defibrillation energies were increased by hypoxia and acidic pHEC, and not by raised [K+]EC. The dominant frequency heterogeneity during ventricular fibrillation in low-flow ischaemia and raised [K+]EC was not due to differential prolongation of …

    glasgow Download PDF for Ventricular fibrillation in ischaemia and its defibrillation (opens in a new tab)

  3. Knowledge and Attitude towards defibrillation in clinician nurse

    … examine the level of knowledge among nurses on defibrillation and the attitude toward the execution of defibrillation, with a view to enhance the level of knowledge among these nurses on defibrillation and promote a positive attitude toward the execution of defibrillation, while providing the …

    ajou Repository record for Knowledge and Attitude towards defibrillation in clinician nurse (opens in a new tab) Embargoed until 9999-12-31

  4. New concepts for use in low-energy cardiac defibrillation

    … field to terminate these waves, as a means of defibrillation. The success of these methods often depends on the orientation of the waves. We present computer simulations of a method that applies multiple electrical fields in a hemispherical shell system representative of the ventricles of the …

    rit Repository record for New concepts for use in low-energy cardiac defibrillation (opens in a new tab)

  5. Nanosecond Stimulation and Defibrillation of Langendorff-Perfused Rabbit Hearts

    The search for novel defibrillation methodologies focuses on minimizing deposition of energy to the heart, as this is an indicator for side effects including pain and tissue death. In this work, we investigate the effect of reducing the duration of the applied shocks from low milliseconds to the …

    odu Repository record for Nanosecond Stimulation and Defibrillation of Langendorff-Perfused Rabbit Hearts (opens in a new tab)

  6. Defibrillation, the coronary venous system and the passive electrode affect

    … and future development of these devices is the defibrillation threshold (the amount of energy required to reliably terminate fibrillation). Changing the vectors of defibrillation through lead positioning has the potential to reduce defibrillation threshold. Current methods for the assessment of …

    soton Download PDF for Defibrillation, the coronary venous system and the passive electrode affect (opens in a new tab)

  7. Propagation Dynamics in Cardiac Tissue: From Alternans Formation to Defibrillation

    … the efficacy of rotational electric fields for defibrillation. Through voltage maps and phase singularity analysis, we present examples demonstrating that rotational fields can defibrillate better than static electric field fields when applied at the same amplitude, suggesting that the use of …

    gatech Repository record for Propagation Dynamics in Cardiac Tissue: From Alternans Formation to Defibrillation (opens in a new tab)

  8. Reduction of Internal Defibrillation Energy Requirements with a New Biphastic Waveform

    Recent literature reports have described reduced defibrillation energy requirements when using truncated biphasic defibrillation waveforms as compared to monophasic defibrillation waveforms. In an attempt to address the question, ''What is significant about biphasic defibrillation waveforms? An …

    marquette Repository record for Reduction of Internal Defibrillation Energy Requirements with a New Biphastic Waveform (opens in a new tab)

  9. A numerical study of cardiac arrhythmia and defibrillation validated by experiments

    Defibrillation is termination of arrhythmias by altering the transmembrane voltage through the delivery of electric shocks. Debates on the mechanisms behind defibrillations, however, have never ceased. More recent studies affirmed the contribution of inhomogeneities to depolarization in tissues …

    gatech Repository record for A numerical study of cardiac arrhythmia and defibrillation validated by experiments (opens in a new tab)

  10. Optimierte linksventrikuläre Stimulation und Defibrillation von der Anatomie bis zur klinischen Anwendung

    … erfordern. Bislang wurden die Veränderungen der Defibrillationsschwelle, die mit der Vergrößerung des linken Ventrikels und dem sich verändernden Stromfluß zwischen der Defibrillationselektrode und dem implantierten Defibrillator selbst einhergehen können, wenig Beachtung geschenkt. Neue …

    fu-berlin Repository record for Optimierte linksventrikuläre Stimulation und Defibrillation von der Anatomie bis zur klinischen Anwendung (opens in a new tab)

  11. The Effect Of Right Ventricular Insertion Cooling On Wavebreak Initiation Following Defibrillation Shocks

    Although strong defibrillation shocks can save patients from life-threating tachyarrhythmias, the function of the heart may be compromised. We found in an earlier study that the right ventricular insertion (RVI) is responsible for most of the initial propagation failure (wavebreak) that drives the …

    uab Repository record for The Effect Of Right Ventricular Insertion Cooling On Wavebreak Initiation Following Defibrillation Shocks (opens in a new tab)

  12. An open source HPC-enabled model of cardiac defibrillation of the human heart

    … of cardiac arrhythmia. Furthermore, electrical defibrillation through the application of strong electric shocks to the heart is the only effective therapy against VF. Over the past decades, a large body of research has dealt with the study of the mechanisms underpinning the success or failure of …

    oxford Repository record for An open source HPC-enabled model of cardiac defibrillation of the human heart (opens in a new tab)

  13. An Investigation of Electrical Surface Impact as a Three-Dimensional Low-Energy Defibrillation Method

    … Previously, we’ve proposed a new low-energy defibrillation method to restore the heart to its normal rhythm during fibrillation. Our method required further investigation due to the presence of several important dynamical processes. In this dissertation, we report the results of these …

    rit Repository record for An Investigation of Electrical Surface Impact as a Three-Dimensional Low-Energy Defibrillation Method (opens in a new tab)

  14. Thermal Preconditioning Effects On Perforation Propensity Of Transvenous Implantable Cardiac Leads Used For Pacing And Defibrillation

    … implantable cardiac leads used for pacing and defibrillation. Leads that were subjected to extreme temperatures and temperature cycling did not show changes in buckle force values compared with control specimens which were maintained at ambient room conditions. Absolute differences between all …

    calpoly Repository record for Thermal Preconditioning Effects On Perforation Propensity Of Transvenous Implantable Cardiac Leads Used For Pacing And Defibrillation (opens in a new tab)

Page 1 of 7