Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 1426 for “"detection limit"”.
-
Where is the Detection Limit?
This report investigates the detection efficiency of the experimental setup LAND/R3B. This is done through Monte Carlo simulations. The simulation software geant4, via the wrapper program ggland, is used with the reconstruction tool land/r3b-tracker. Beams of different isotopes of carbon, boron and …
-
Improving the Detection Limit of Tau Aggregates for Use with Biological Samples
… tissue. This assay can be used not only for detection, but also to note differences between tauopathies and to look at various agents that have been shown to block fibril growth.
-
Species Distribution Modeling: Implications of Modeling Approaches, Biotic Effects, Sample Size, and Detection Limit
… model sensitivity at different sample size and detection limit levels, which may be useful for predicting species presences when data are limited. Random forests performed consistently well at different sample size levels, but was more sensitive to high detection limit. The performance of …
-
Accounting for the Uncertainty Due to Chemicals Below the Detection Limit in Mixture Analysis
… measures each exposure to a chemical-specific detection limit, the exposures are unknown between zero and the detection limit. Indeed, the number of exposures below the detection limit (BDL) is so pervasive that complete-case analyses would remove all or most of the subjects in many studies. As …
-
Multiple imputation in the presence of a detection limit, with applications : an empirical approach
… that are typically reported as less than a fixed detection limit. This especially occurs in the environmental sciences when detection of low exposures are not possible due to limitations of the measuring instrument, and the resulting data are often referred to as type I and II left censored data. …
-
Model-based Imputation of Below Detection Limit Missing Data and Group Selection in Bayesian Group Index Regression
… analyses is the ubiquitous presence of below detection limit (BDL) data. We propose an extension of Bayesian group index regression that treats both regression effects and missing BDL observations as parameters in a model estimated through a Markov Chain Monte Carlo algorithm that we refer to …
-
Factors to consider in the indoor environment when evaluating the risk of human health at the environmental detection limit
Quantitative analysis of the limit of detection, sample recovery efficiency (SRE) and characterization of the microbial community are necessary parameters for accurate exposure assessment as part of the quantitative microbial risk assessment framework for indoor environments. To control and …
-
Early Detection System for Water Quality Monitoring of Cyanobacteria and Hexavalent Chromium using UV-Vis Derivative Spectrophotometry and Improvement of Detection Limit by Changing Pathlength
… mm pathlength, respectively. The lowest method detection limit (MDL) was observed using 100 mm and the concentration was found to be 4,916 cells/mL (for cyanobacteria), which is well below the WHO guideline for low probability of adverse health effects (< 20,000 cells/mL). Additionally, the …
-
Development of PYRAMDS (Python for Radioisotope Analysis and Multi-Detector Suppression) code used in fission product detection limit improvements with the DGF Pixie-4 digital spectrometer
… was also to characterize the improvements in the detection limits and the various detector efficiencies from this method as opposed to creating these spectra using traditional electronic gating systems. A focus is placed on the detection capability improvements for nuclear forensics purposes, …
-
A modified bootstrap method for handling non detects in environmental data
… have concentrations that are measured below the detection limit. Below the detection limit does not mean that there is no concentration present; there may be a concentration present that cannot be accurately measured by the analytical instrument or cannot be determined with 95% confidence that …
-
Dechlorinating and Iron Reducing Bacteria Distribution in a Trichloroethene Contaminated Aquifer
… with densities lower than 3.2x104 copies/g (detection limit of 2.5x103). D. michiganensis distribution was not uniform but was clustered near the TCE-source area with densities of 7.9x103-1x105 copies/g (detection limit of 6.3x103). Geobacter spp. distribution was uneven but broader, with …
-
Exploring Different Approaches to Improve the Analytical Performance of Inductively Coupled Plasma Optical Emission Spectrometry with Pneumatic Nebulization or Electrothermal Vaporization
… efficiency and concurrently improve sensitivity, detection limit and plasma robustness of ICPOES. A cyclonic spray chamber was modified so as to insert an IR lamp heater inside it. The modified cyclonic (MC) spray chamber was heated up to 150 °C. Using a pre-evaporation tube (PET) between the MC …
-
Graphene Sensors for Ultra-Trace Detection of Environmental Contaminants
… low cost, and compatibility with real-time detection. However, conventional sensing platforms often suffer from limited sensitivity, restricted transduction mechanisms, and limited adaptability to chemically diverse analytes, particularly for ultra-trace detection. This dissertation …
-
Biomarker Detection at Risk Forecasting Level Using Metal-Enhanced Fluorescence Combined with Surface Acoustic Wave
… (MEF) technique is used to lower the detection limit of carcinoembryonic antigen (CEA) which is able to be utilized in forecasting the risk of having certain kinds of cancers, especially colon and rectal cancer. By incubating silver nanocubes (Ag NCs) on the surface of the chips, the …
-
Cancer Biomarker Detection in Human Plasma by Integrating Surface Acoustic Wave and Metal-Enhanced Fluorescence
… metal-enhanced fluorescence (MEF) to lower the detection limit of carcinoembryonic antigen (CEA). The detection limit goes down to 100pg/mL level when using MEF substrate made by rapid thermally annealed silver film covered by silica, which has great promise in diagnosing certain types of cancer …
-
Nanoparticle biosensors: understanding and detection at low concentrations
Detection of analyte in low concentrations has aroused research into the use of nanostructured electrodes to lower the detection limit and decrease response time. Limitations of low concentrations sensing are; the relatively few analyte present in solution (low signal) and a long diffusion of the …
-
The Atomisation And Determination Of Volatile Metals In Coal
… developed. With a manual injection technique the detection limit was 0.01 ng. Replacement with a continuous flow system yielded a more rapid and precise method with a detection limit of C.045 ng.ml-¹. Quantitative recoveries of mercury from a standard coal were obtained through liberation of the …
-
Determination of hydrogen peroxide using immobilized chemiluminescence reagents and flow injection analysis
… peroxide using solution-phase hemin as catalyst (detection limit = 0.4 $\mu$M, relative standard deviation (rsd) = 2.5%). Next, horseradish peroxidase (HRP) was immobilized on nylon membranes. Luminol was immobilized on to an anion exchange resin and packed in a column. When used in the FIA mode, …
-
The Determination of 210Pb by Accelerator Mass Spectrometry
… easily removed without negatively impacting the detection limit for 210Pb. 205Pb+3 continually suffered from 205Tl+3 interference which could be readily be removed but not without negatively affecting the II detection limit for 210Pb. 208Pb+3 suffers from no molecular interferences but if a large …
Page 1 of 72