Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 24 for “"detector response function"”

  1. Components of detector response function : experiment and monte carlo simulations

    Components of the response function of a high-purity germanium (HPGe) detector due to full or partial energy deposition by gamma- and X-rays were studied. Experimental response functions for 241Am, Ba and Tb were compared with those obtained from the Monte Carlo simulations. The role of physical …

    metu Repository record for Components of detector response function : experiment and monte carlo simulations (opens in a new tab)

  2. A Hybrid Radiation Transport Detector Response Function Methodology for Modeling Contaminated Sites

    … techniques – specifically relating photon detector responses to dose or cancer risk-based radionuclides concentrations in environmental media – exist under the Environmental Protection Agency (EPA) Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). In recent …

    gatech Repository record for A Hybrid Radiation Transport Detector Response Function Methodology for Modeling Contaminated Sites (opens in a new tab)

  3. A MONTE CARLO SIMULATION AND DECONVOLUTION STUDY OF DETECTOR RESPONSE FUNCTION FOR SMALL FIELD MEASUREMENTS

    Different types of radiation detectors are routinely used for the dosimetry of photon beams. Finite detector sizes have certain effects to the broadening of the measured beam penumbra. The problem is more important in small field measurement, such as stereotactic radiosurgery, small beamlet IMRT, …

    ohiolink Repository record for A MONTE CARLO SIMULATION AND DECONVOLUTION STUDY OF DETECTOR RESPONSE FUNCTION FOR SMALL FIELD MEASUREMENTS (opens in a new tab)

  4. FABRICATION, MEASUREMENTS, AND MODELING OF SEMICONDUCTOR RADIATION DETECTORS FOR IMAGING AND DETECTOR RESPONSE FUNCTIONS

    … The alpha-tagging sensor is a double-sided strip detector made from polycrystalline CVD diamond. The performance goals of the alpha-tagging sensor are 700-picosecond timing resolution and 0.5 mm spatial resolution. A literature review summarizes the methodology, goals, and challenges in associated …

    utk-theses Repository record for FABRICATION, MEASUREMENTS, AND MODELING OF SEMICONDUCTOR RADIATION DETECTORS FOR IMAGING AND DETECTOR RESPONSE FUNCTIONS (opens in a new tab)

  5. Method development and performance study of Geant4 and Gold's algorithm for gamma spectral unfolding

    … energy distribution of a gamma field from the response function of the gamma detector. To do this, an iterative matrix-unfolding algorithm is applied to measurements and a detector response function. Using empirical data and Geant4, a monte carlo radiation transport code, the response function …

    gatech Repository record for Method development and performance study of Geant4 and Gold's algorithm for gamma spectral unfolding (opens in a new tab)

  6. Gamma/neutron separation in the Martian radiation environment

    … part of the rover is the Radiation Assessment Detector (RAD) which will measure a broad spectrum of energetic particles at the surface of Mars. The instrument consists of a silicon detector telescope stack followed by two scintillators which are enclosed by an anticoincidence. The high-Z …

    cau-kiel Repository record for Gamma/neutron separation in the Martian radiation environment (opens in a new tab)

  7. Study of LaBr3 (Ce) detector response to high energy helium ions

    … devices. Lanthanum Bromide scintillator detector (LaBe3: Ce) has been successfully used as a gamma spectrometer inside space crafts. However, data on its response to other particles such as charged particles remains limited. From a radiation protection perspective, it is important to …

    uoit Repository record for Study of LaBr3 (Ce) detector response to high energy helium ions (opens in a new tab)

  8. On black holes in BMN plane wave

    … state in the BMN background, we study the response of an Unruh monople detector following various trajectories. The detector response function shows the vacuum state natural to the BMN plane wave has very different thermal behavior from the Minkowski vacuum. In particular, observers …

    ubc Repository record for On black holes in BMN plane wave (opens in a new tab)

  9. The application of Bayesian statistics and maximum entropy to Ion beam analysis techniques

    … of some blurring property, such as the detector response function, from spectra has received a considerable amount of attention. The problem is usually complicated by the presence of noise in the data, and in general, there exists an infinite set of possible solutions which are …

    cape-town Repository record for The application of Bayesian statistics and maximum entropy to Ion beam analysis techniques (opens in a new tab)

  10. Development of a Benchmark Problem and Implementation of the DRF Methodology for Reactor Dosimetry in the Extended Beltine Region

    … operation is prompting innovation in dosimeter response solving methods to aid in understanding material embrittlement of nuclear reactor pressure vessels. This innovation is possible due to improved computational hardware and simulation techniques which allow analysis of 3-D response …

    vt Repository record for Development of a Benchmark Problem and Implementation of the DRF Methodology for Reactor Dosimetry in the Extended Beltine Region (opens in a new tab)

  11. Fundamental and Applied Aspects of X-Ray Spectrometry: Detector Influence and Photoelectric Effect Cross-Sections

    … a radiation measurement from the effects of the detector-pulse handling circuitry system. These strategies comprise the correction from the effects of pulse pile-up (PPU) and the detector response function (DRF). A first principles balance equation for second order PPU is derived and solved for …

    bologna Repository record for Fundamental and Applied Aspects of X-Ray Spectrometry: Detector Influence and Photoelectric Effect Cross-Sections (opens in a new tab)

  12. Neutron Spectroscopy with Scintillation Detectors using Wavelets

    … it safer to use, as well as easier to design detectors. The material was also manufactured with inherent pulse shape discrimination abilities, making it suitable for use in neutron detection. The neutron spectral unfolding technique was developed in two stages. Initial detector response …

    unlv Repository record for Neutron Spectroscopy with Scintillation Detectors using Wavelets (opens in a new tab)

  13. Novel detector developments for positron emission tomography

    … concerned with the development of novel detector techniques for Positron Emission Tomography (PET). In recent years, PET has evolved to the extent that the technique is routinely used to provide valuable quantative information related to a variety of health care problems. A review of the …

    soton Repository record for Novel detector developments for positron emission tomography (opens in a new tab)

  14. Photoluminescence studies of silicon doped with copper and zinc

    … deconvolution techniques to correct for the detector response function. A rapid fall off is observed for the decay time over the temperature range 50 - 100K, corresponding to thermalization over an energy barrier of 65 mev. The data is interpreted in terms of an isoelectronic bound exciton. …

    dcu Repository record for Photoluminescence studies of silicon doped with copper and zinc (opens in a new tab)

  15. ModPET: Novel Applications of Scintillation Cameras to Preclinical PET

    … of 511-keV photons and a new iterative mean-detector-response-function processing routine. Intrinsic lateral spatial resolution for 511-keV photons was found to be approximately 1.6 mm in each direction. Lists of coincidence pairs are found by comparing event times in the two independent …

    arizona-thes Repository record for ModPET: Novel Applications of Scintillation Cameras to Preclinical PET (opens in a new tab)

  16. Karlsruhe Tritium Experiment: Detector System Commissioning and In-Situ PIN-Diode Array Dead-Layer Measurement

    … resolution, but a confluence of focal plane detector parameters contribute to the uncertainty in the measured neutrino mass including the detector backgrounds and the detector electron response function. The detector system group developed a figure of demerit, <italic>F</italic>, to quantify …

    washington Repository record for Karlsruhe Tritium Experiment: Detector System Commissioning and In-Situ PIN-Diode Array Dead-Layer Measurement (opens in a new tab)

  17. Probing Power-Absorbing Structures at Near-Infrared Wavelengths using Energy Absorption Interferometry

    … capable of fully characterizing the optical response of single-mode, few-mode and multi- mode power-absorbing structures, such as near-infrared detectors. A detector’s output can be written as the full spatial contraction of the external field correlation tensor and detector response …

    cambridge Repository record for Probing Power-Absorbing Structures at Near-Infrared Wavelengths using Energy Absorption Interferometry (opens in a new tab)

  18. Ultrafast Terahertz Control of Structural and Charge Carrier Dynamics in Emerging Semiconductors

    … alpha-quartz plates as a novel electro-optic detector for full amplitude, phase, and polarization characterization of high THz fields. By determining the quartz detector response function and developing a protocol for measuring arbitrary THz polarization and helicity states, this work …

    fu-berlin Repository record for Ultrafast Terahertz Control of Structural and Charge Carrier Dynamics in Emerging Semiconductors (opens in a new tab)

  19. SuperCDMS Background Models for Low-Mass Dark Matter Searches

    … the SuperCDMS experiment in 2012. The germanium detectors were operated at 50~mK and able to measure both the ionization and athermal phonons produced in a particle interaction. Measuring two signals enables discrimination between electron recoil and nuclear recoil events. An alternative …

    umn Repository record for SuperCDMS Background Models for Low-Mass Dark Matter Searches (opens in a new tab)

  20. On-board Single Photon Emission Computed Tomography (SPECT) for Biological Target Localization

    … locations. Also investigated were the effects of detector response function compensation (DRC) and observer normalization on target localization. Localization performance was optimized as a function of iteration number and degree of post-reconstruction smoothing. Localization error patterns were …

    duke Repository record for On-board Single Photon Emission Computed Tomography (SPECT) for Biological Target Localization (opens in a new tab)

Page 1 of 2