Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 10 of 10 for “"dial indicator"”.
-
The Incorporation of Aluminum Hydroxide in Water Based Muds to Stabilize Marcellus Shale Drilling in West Virginia
… was designed by modifying a 0.001 mm resolution dial indicator and using a specially programmed smart cable connecting the dial indicator to a computer. The swelling data was acquired by the smart cable every six seconds. As a result, there were 14,400 measured points for each sample for the 24 …
-
Use of a Portland Cement Accelerator with Mineral Trioxide Aggregate
… as the control. Samples were tested using a dial indicator microgauge apparatus that measured the depth of needle penetration starting at 2 minutes and then every minute up to 15 minutes. Samples were also tested at 3, 4, 24, 48 and 72 hours. A mixed-model repeated measures ANOVA showed the …
-
Translation of the Tibia During Isometric Contraction of the Quadriceps
… tested. Tibial translation was measured with a dial indicator at 15, 45 and 60 degrees of knee flexion. There was a measurable anterior translation of the tibia in all knees. An analysis of variance with post hoc testing of two weighted contrasts showed a significant increase from normal in …
-
Recovery Effects on the Performance of Athletic Shoes
… was tracked during each rest period using a dial indicator. The results of the aging study show that rest does have an impact on midsole performance only after approximately 15.83 km. No trend was seen among the 1, 2, or 3 days of rest following the protocol aging which may indicate that …
-
The measurement of static deflections in spur gear teeth
… 1938 measured deflection of gear teeth using a dial indicator. Timoshenko and Baud proposed that a rigidly fired, tapered cantilever beam be used to approximate the actual tooth, and derived equations to predict deflection of that equivalent tooth. They were not specific in how the equations …
-
Noise analysis of high voltage capacitors and dry-type air-core reactors
… and the compression was measured with a dial indicator at various points. The compression was deemed to be linearly dependent on the distance from the middle point of the surface of the element. In order to measure the response of the whole capacitor, a vibration measurement was used. …
-
Physical and mechanical properties of experimental dentinogenic pulp capping material
… the ISO specification 6876 using digital dial indicator. The pH level of the storage solutions of each specimen in deionized water was measured after 2 hours, and 1, 7, 21, and 28 days. The compressive strength was measured following the ISO specification 9917, and solubility was measured …
-
A STUDY OF HYDROXYPROPYLMETHYLCELLULOSE MATRICES
… the vertical displacement with time using a dial indicator. Curve-fitting of the data of swelling was carried out by using the coupled Case I-Case II model used in liquid penetration process. The thickness of swollen layer formed around the matrix core was higher in HPMC compacts of higher …
-
Tvorba edukační úlohy pro výuku geometrických tolerancí
Bakalářská práce je rozdělena na dvě části. V první je zpracována rešerše pojednávající o geometrických tolerancích, jejich rozdělení, značení, vyhodnocování atd. Druhá část je praktická. Zde je využito znalostí získaných z rešeršní části k měření skutečné součásti, která byla přímo pro účely této …
-
Způsoby měření geometrických tolerancí
Bakalářská práce se zabývá rozborem geometrického tolerování strojních součástí. V této práci jsou objasněny pojmy a definice spojené s geometrickým tolerováním, rozebrány metody měření jednotlivých geometrických tolerancí spolu s popisem měřicích přístrojů a měřidel. Je zde také navržena metoda …