Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"diaphragm thickness"”.

  1. Ultrasound Imaging for the Examination of Diaphragm Thickness in Females with Breathing Pattern Disorders

    This research examined diaphragm thickness and diaphragm thickening fraction, using ultrasound imaging (USI), in females with breathing pattern disorders (BPD) and healthy female controls. The diaphragm is the key muscle of respiration, and people with BPD present with breathing that has increased …

    auckland-tech Repository record for Ultrasound Imaging for the Examination of Diaphragm Thickness in Females with Breathing Pattern Disorders (opens in a new tab)

  2. A fiber optic pressure transducer.

    … and receive reflected light from a pressure diaphragm. The amount of light returned to a photosensor was dependent upon the diaphragm shape and relative position from the optic fiber bundle. The response was linear over a pressure range which was dependent upon the diaphragm thickness. …

    nps Repository record for A fiber optic pressure transducer. (opens in a new tab)

  3. Diaphragm Activity and Function During Mechanical Ventilation

    … that mechanical ventilation (MV) can injure the diaphragm, potentially prolonging ventilator dependence. However, there are many potential insults to diaphragm function during critical illness and the extent to which diaphragm dysfunction is attributable to ventilation remains undefined in the …

    toronto-retro Repository record for Diaphragm Activity and Function During Mechanical Ventilation (opens in a new tab)

  4. Fiber optic and laser digital pressure transducers.

    … to transmit light to and from the transducer diaphragm. Response was linear through 60 inches Hg. Linearity and sensitivity of response were dependent on diaphragm thickness and probe location, respectively. In a separate experiment, a gas laser was externally modulated by means of a moveable …

    nps Repository record for Fiber optic and laser digital pressure transducers. (opens in a new tab)

  5. Patient-ventilator asynchrony : effects on diaphragm structure and function

    … on mode and length of ventilation, influences diaphragm structure and function, and by extension, may influence outcomes. Patient–ventilator asynchrony imposes an additional burden on the respiratory system and may increase the morbidity of critically ill patients. The asynchrony index (AI) is …

    ubc Repository record for Patient-ventilator asynchrony : effects on diaphragm structure and function (opens in a new tab) Download PDF for Patient-ventilator asynchrony : effects on diaphragm structure and function (opens in a new tab)

  6. Electrostatic Micro Gas Pumping for Micro Gas Chromatography Systems---Fabrication and Experiments

    For the pump to perform as designed, the diaphragm has to fully zip and the inlet/outlet valves need to open and close as the diaphragm actuates. As an actuation compresses gas, the outlet valve should open with the inlet valve closed so that the gas flows out. As the diaphragm releases, the outlet …

    uiuc Repository record for Electrostatic Micro Gas Pumping for Micro Gas Chromatography Systems---Fabrication and Experiments (opens in a new tab)

  7. Efeito do treinamento muscular inspiratório com diferentes cargas na força e função de músculos respiratórios

    … To investigate the effect of IMT on the diaphragmatic muscle strength and function neural and structural adjustment of diaphragm in sedentary young people, compare the effects of low intensity IMT with moderate intensity IMT on the thickness, mobility and electrical activity of diaphragm …

    brazil-ufrn Repository record for Efeito do treinamento muscular inspiratório com diferentes cargas na força e função de músculos respiratórios (opens in a new tab)

  8. Analysis and design of steel-deck-reinforced concrete diaphragms

    … behavior, strength and stiffness of floor diaphragms constructed with steel-deck-reinforced concrete was investigated in this study. As part of the research, 23 full size experimental diaphragms were tested in a reversed cyclic manner on a cantilever test frame. Experimental parameters that …

    iastate Repository record for Analysis and design of steel-deck-reinforced concrete diaphragms (opens in a new tab)

  9. Assessment of the risk of post-operative pulmonary complications and mortality using analytic morphometry in patients undergoing major non-cardiac surgery

    … of indices of body composition including psoas, diaphragm muscles, and abdominal adipose tissue identified diaphragm thickness as an important morphomarker that may be useful in identifying patients at risk of developing PPC. I also analysed these in the context of survival, demonstrating a …

    birmingham Download PDF for Assessment of the risk of post-operative pulmonary complications and mortality using analytic morphometry in patients undergoing major non-cardiac surgery (opens in a new tab)

  10. Treinamento muscular inspiratório na apneia obstrutiva do sono do idoso : ensaio clínico randomizado

    … patients repeated the respiratory polygraphy, diaphragm thickness (DT), spirometry, and manovacuometry at 8 weeks. Results: Patients in the IMT group completed the protocol with an average reduction in AHI of 1.6 events per hour (95% confidence interval -4.8 to 1.6). In the sham-IMT group the …

    brazil-ufrgs Repository record for Treinamento muscular inspiratório na apneia obstrutiva do sono do idoso : ensaio clínico randomizado (opens in a new tab)

  11. A high temperature pressure sensor based on magnetic coupling and silicon wafer bonding

    … the sensor are two inductive coils, a silicon diaphragm and a hermetic vacuum cavity. The modeling based on a nine-turn single level coil device and a 300 um x 300 diaphragm indicates an output rms voltage range of 70 mV with an input current of 100 mA and frequency of 200 MHz at pressures …

    njit Repository record for A high temperature pressure sensor based on magnetic coupling and silicon wafer bonding (opens in a new tab)

  12. Hyper-Sensitive MEMS Pressure Sensor Array for Microscale Bubble Pressure Measurement

    … utilizes an extremely thin 225 nm square Si3N4 diaphragm which is produced by etching away the bulk silicon with XeF2 through holes present in the diaphragm. A unique process flow was developed to achieve the diaphragm thickness in nanometers. Four polysilicon piezoresistors, mounted on the …

    rit Repository record for Hyper-Sensitive MEMS Pressure Sensor Array for Microscale Bubble Pressure Measurement (opens in a new tab)

  13. Thermal optimization of a polyimide V-groove actuator for a walking micro-robot

    … was observed for the case of "uniform diaphragm thickness at the V-groove bottom". The optimization module of ANSYS was used for optimizing the thickness of the silicon diaphragm (referred to as "single variable optimal design"). Steady state analysis showed that there is an improvement …

    rit Repository record for Thermal optimization of a polyimide V-groove actuator for a walking micro-robot (opens in a new tab)

  14. Musculoskeletal and respiratory adaptations of a holistic therapeutic exercise program targeting diastasis recti abdominis in women

    … strengthening, though evidence suggests that the diaphragm, pelvic floor and transversus abdominus have a central role in trunk stability and function. This randomized controlled trial (RCT), developed through a systematic multistage preparatory process, evaluated the effectiveness of a holistic …

    greece Repository record for Musculoskeletal and respiratory adaptations of a holistic therapeutic exercise program targeting diastasis recti abdominis in women (opens in a new tab)

  15. Fabrication and Application of Flexible Sensors

    … as small as 125 µm, while the obtained PDMS thickness was as low as 27.1 µm, which enabled the fabrication of highly sensitive force and pressure sensors. The transfer printing method was employed to fabricate a two-dimensional force sensor, which was composed of lines of carbon nanotubes in …

    lsu-thes Repository record for Fabrication and Application of Flexible Sensors (opens in a new tab)

  16. Diagnostika diafragmového výboje ve vodných roztocích a jeho aplikace pro povrchovou úpravu nanomateriálů

    Přesný mechanizmus samotného zapálení výboje v roztocích není dosud znám, ačkoli v posledních několika letech došlo k velkému pokroku a přiblížením, z nichž některá jsou nastíněna v teoretické části práce. Tato práce je rozdělena na dvě experimentální části. První část se zabývá diagnostikou …

    brno-tech Repository record for Diagnostika diafragmového výboje ve vodných roztocích a jeho aplikace pro povrchovou úpravu nanomateriálů (opens in a new tab)