Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"difference amplifier"”.

  1. Measured noise performance of a new method of frequency hopping

    … a frequency to voltage converter and then uses difference amplifier circuits to compare the received sequence with all utilized sequences for data recovery. This report presents the design and results of this PH technique. A bit probability of error of 0.001 at 1.6 dB SNR was obtained.

    nps Repository record for Measured noise performance of a new method of frequency hopping (opens in a new tab)

  2. Analysis and development of the high frequency common-mode rejection of an instrumentation amplifier

    … development and analysis of an instrumentation amplifier in the mid-band and high frequency regions. The common-mode gain of a simple difference amplifier configuration is analyzed in detail to find the limitations due to nonideal properties of an op-amp. Compensation methods are then …

    ut-knoxville Repository record for Analysis and development of the high frequency common-mode rejection of an instrumentation amplifier (opens in a new tab)

  3. Automatic tuning for linearly tunable filter

    … reference clock generator, and differential difference amplifier (DDA) for dealing with frequency and Q factor tuning loop and linearly tunable second order gm-C bandpass filter. Simulation results for a 10 MHz prototype filter using AMI 0.5μm process is presented. The chip testing results …

    tamu Repository record for Automatic tuning for linearly tunable filter (opens in a new tab)

  4. Dual Extension CMOS Imager and Peripherals for Biomedical Applications

    … a single column parallel partitioned pixel amplifier with variable topology for the detection of both high and low light levels in the same frame. For fluorescence detection the fabrication of a low cost poly-acrylic acid (PAA) based emission filter integrated with the CMOS contact imager is …

    calgary Repository record for Dual Extension CMOS Imager and Peripherals for Biomedical Applications (opens in a new tab)

  5. Analog Front-End Design Using the gm/ID Method for a Pulse-Based Plasma Impedance Probe System

    … of the analog front-end, the non-inverting amplifier that is used to drive the antenna. The antenna immersed in plasma is excited with a sinusoidal/pulse stimulus and the output from the non-inverting configuration is fed into the difference amplifier. In the difference amplifier the output …

    utahstate Repository record for Analog Front-End Design Using the gm/ID Method for a Pulse-Based Plasma Impedance Probe System (opens in a new tab)

  6. Low noise design of a buffered direct injection transconductance preamplifier for a focal plane array

    … injection (BDI) common gate transconductance preamplifiers are typically used to couple infrared focal plane arrays to signal processing circuitry. This yields improved charge transfer efficiency over other methods of charge coupled device (CCD) readout. The use of CMOS technology in this stage …

    ucf Repository record for Low noise design of a buffered direct injection transconductance preamplifier for a focal plane array (opens in a new tab)

  7. Design of a 3.3 V analog video line driver with controlled output impedance

    … cable or twisted pair. The line driver is an amplifier that provides the necessary output current to drive the low impedance of the line. The main requirements for design are high output swing, high linearity, matched impedance to the line and power efficiency. These requirements are addressed …

    tamu Repository record for Design of a 3.3 V analog video line driver with controlled output impedance (opens in a new tab)

  8. Návrh analogových obvodů s nízkým napájecím napětím a nízkým příkonem

    … typu OTA (operational transconductance amplifier), CCII (second generation current conveyor), FB-CCII (fully-differential second generation current conveyor), FB-DDA (fully-balanced differential difference amplifier), VDTA (voltage differencing transconductance amplifier), CC-CDBA …

    brno-tech Repository record for Návrh analogových obvodů s nízkým napájecím napětím a nízkým příkonem (opens in a new tab)

  9. A High-Resolution Direct-Conversion CMOS X-Ray Imager with Code-Division-Multiplexed Readout

    … dual integrator and switched-capacitor difference amplifier (SCDA) to implement the CDM readout. We also show how the pixel size, frame rate, and readout resolution design specifications are met. We implement our imager in a 180-nm CMOS process and also discuss the design of external …

    waterloo Repository record for A High-Resolution Direct-Conversion CMOS X-Ray Imager with Code-Division-Multiplexed Readout (opens in a new tab)

  10. The Design of a Portable Guided SH-SAW Sensor Platform for Liquid Phase Environments

    … This is done with the use of a phase shifter, difference amplifier and an envelope detector. The amplitude output is a DC value of the difference between the two signals. The phase is also measured by comparing a reference signal and a sensing signal. The phase detector has a DC output …

    marquette Repository record for The Design of a Portable Guided SH-SAW Sensor Platform for Liquid Phase Environments (opens in a new tab)

  11. Topologies for programmable analogue circuits

    … tests for the chosen CAB called the Differential Difference Amplifier (DDA) integrated with the second generation Current Conveyor (CCII), to form the hybrid DDACCII CAB. The implementation of a cluster based hierarchical architecture, following a similar concept to the HFPGAs (Hierarchical Field …

    soton Download PDF for Topologies for programmable analogue circuits (opens in a new tab)

  12. Low Power Circuits for Smart Flexible ECG Sensors

    … studied in this research. A fully differential difference amplifier (FDDA) based AFE that employs DC-coupled input stage increases the input impedance and improves CMRR. A parasitic capacitor reuse technique is proposed to improve the noise/area efficiency and CMRR. An on-body DC bias scheme is …

    york Repository record for Low Power Circuits for Smart Flexible ECG Sensors (opens in a new tab)

  13. An Optimization Method for Near-Linear Phase Analog Frequency Sampling Filter Design

    … signal with the original signal through a difference amplifier and then through a fully differential active biquad. The resonators are also implemented using fully differential active biquads. The resulting SPICE simulations closely match the MATLAB models, demonstrating the feasibility of …

    unlv Repository record for An Optimization Method for Near-Linear Phase Analog Frequency Sampling Filter Design (opens in a new tab) Download PDF for An Optimization Method for Near-Linear Phase Analog Frequency Sampling Filter Design (opens in a new tab)

  14. Bandgap voltage references with curvature elimination for temperature independence

    … Nonlinear Function Generator (NFG), and a difference amplifier. The NFG implements a nonlinear function of the output of the TDC. This nonlinear function, which is implemented in the digital domain to prevent the introduction of error, contains temperature-dependent terms whose coefficients …

    iastate Repository record for Bandgap voltage references with curvature elimination for temperature independence (opens in a new tab)

  15. A Matched Filter and Coherent Digitizer for Pulsed Doppler Radar Systems

    … filter based on current-reuse differential difference amplifiers, which is used as an anti-alias filter, will be presented. The two differential pairs in the differential difference amplifier process two independent input signals but share the same output and bias current. To demonstrate the …

    tamu Repository record for A Matched Filter and Coherent Digitizer for Pulsed Doppler Radar Systems (opens in a new tab)

  16. Temperature stabilized circuits with calibration and curvature elimination

    … Nonlinear Function Generator (NFG), and a difference amplifier. The NFG implements a nonlinear function of the output of the TDC. This nonlinear function, which is implemented in the digital domain to prevent the introduction of error, contains temperature-dependent terms whose coefficients …

    iastate Repository record for Temperature stabilized circuits with calibration and curvature elimination (opens in a new tab)

  17. Full-custom analog-mixed signal components for CMOS integrated autonomous microelectronic systems

    … <br> <br>Processing Units: A differential difference amplifier was implemented as analog readout frontend for stress sensors. It utilizes an amplitude related gain selection to actively regulate the total harmonic distortion to less than 2%, and a current injection path to improve the power …

    freiburg-diss Repository record for Full-custom analog-mixed signal components for CMOS integrated autonomous microelectronic systems (opens in a new tab)

  18. Návrh diferenčně diferenciálního zesilovače v technologii CMOS

    Bakalárska práca sa zaoberá teoretickým rozborom parametrov a vlastností technológie CMOS, a jej využitím pri návrhu diferenčne diferenciálneho zosilňovača. Práca je zameraná na správanie MOS tranzistorov v rôznych pracovných režimoch v závislosti na veľkosti napätia UGS, tiež rozoberá pracovné …

    brno-tech Repository record for Návrh diferenčně diferenciálního zesilovače v technologii CMOS (opens in a new tab)

  19. Návrh extrémně nízkonapěťového operačního zesilovače

    Práce se zabývá návrhem nízkonapěťového operačního zesilovače. V první části práce jsou uvedeny teoretické poznatky týkající se technologie CMOS a MOSFET tranzistoru. V další části jsou popsány jednotlivé techniky používané při návrhu nízkonapěťových obvodů. Následně je navržen dvoustupňový …

    brno-tech Repository record for Návrh extrémně nízkonapěťového operačního zesilovače (opens in a new tab)

  20. Předzesilovače pro zpracování biologických signálů

    Práce se zabývá problematikou návrhu a optimalizace zesilovačů v technologii CMOS s nízkým napájecím napětím a nízkou spotřebou. Hlavním zaměřením práce je navrhnout zesilovač pro zesílení biologických signálu. V první části práce je stručný úvod do teorie biologických signálů. Dále práce obsahuje …

    brno-tech Repository record for Předzesilovače pro zpracování biologických signálů (opens in a new tab)

Page 1 of 2