Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"difference signal"”.

  1. Motion compensation using correlation-feedback

    … motion to obtain the motion-compensated frame difference signal. This work uses the correlation-feedback approach to estimate the velocity or the optic flow of the moving image pixel. After the motion of the pixel is estimated. the motion-compensated frame difference signal is found by …

    njit Repository record for Motion compensation using correlation-feedback (opens in a new tab)

  2. Study of an Automatic Sphygmomanometer System

    … diastolic pressure from the amplitude of the difference signal obtained by subtracting the pulse wave observed in one cuff from that of the other, and to determine systolic pressure from the amplitude of the pulse wave observed in the cuff furthermost from the heart. Although the system is …

    sdstate Repository record for Study of an Automatic Sphygmomanometer System (opens in a new tab)

  3. Real-time measurement of television image activity

    … capable of real-time processing of video signals has been implemented for the purpose of measuring image activity in television programs. The basis of the system is a digital preprocessor that yields data sets which describe the difference between selected fields of an input video signal. …

    carleton Repository record for Real-time measurement of television image activity (opens in a new tab)

  4. CROSS-EYE JAMMING AND THE USE OF UAVS AS A CROSS-EYE JAMMER PLATFORM

    … received lobes of the target and use the sum and difference of these lobes to track the target. Cross-eye jamming interferes with the difference signal, and it strives to point the radar beam away from the target. Two jammers, usually at the edges of the target wings, receive a pulse from the …

    nps Repository record for CROSS-EYE JAMMING AND THE USE OF UAVS AS A CROSS-EYE JAMMER PLATFORM (opens in a new tab)

  5. Synthesis of computations and experiments for obtaining pulsatile gas flow rates from dynamic pressure difference measurements across an orifice-plate meter

    … signature of the imposed dynamic pressure difference and, furthermore, they have fluctuation amplitudes that are significantly larger than those associated with turbulence or random acoustic wave signatures. The experimental aspect of the proposed calibration approach is based on use of …

    mtu Repository record for Synthesis of computations and experiments for obtaining pulsatile gas flow rates from dynamic pressure difference measurements across an orifice-plate meter (opens in a new tab)

  6. Adaptive subband video coding with motion compensation

    … in the worst case. The motion compensated frame difference signal is encoded with a new technique — subband adaptive vector quantization.</p><p>Subband coding like transform coding results in signals of unequal energy patterns, which is efficiently utilized for bit allocation. In addition, the …

    njit Repository record for Adaptive subband video coding with motion compensation (opens in a new tab)

  7. Algorithms to detect and damp power oscillations in electric power systems

    … as on both local measurements and phase angle differences between voltage vectors in different parts of the power system. A synchronized Phasor Measurement Unit (PMU), provided by ABB, was used to obtain the phase angle difference between two buses, and in this way, power oscillations could be …

    chalmers Repository record for Algorithms to detect and damp power oscillations in electric power systems (opens in a new tab)

  8. Development and characterization of a hydrogen peroxide sensor using catalase immobilized on a pyroelectric poly(vinylidene fluoride) film

    … A differential instrument amplifier produces a difference signal from a sample and reference PVDF film. This removes noise caused by stray electromagnetic radiation and piezoelectric pressure responses. A conventional Flow Injection Analysis unit was employed. The FIA flow rate was four ml/min …

    vt Repository record for Development and characterization of a hydrogen peroxide sensor using catalase immobilized on a pyroelectric poly(vinylidene fluoride) film (opens in a new tab)

  9. A robust wide area measurement based controller for networks with embedded HVDC links

    … interest in the use of non-local feedback signals for power swing damping control. Although damping can be improved through generator excitation systems, dc links and other grid connected power electronic converters, the full potential of wide-area measurements can be realized by …

    manitoba Repository record for A robust wide area measurement based controller for networks with embedded HVDC links (opens in a new tab)

  10. PROBING PROFICIENCY-RELATED NEURAL REPRESENTATIONS WITH PCA AND ICA

    … sweeps further show that proficiency-related signal is not tied to a single arbitrary number of components, but depends on representational scale, and that this scale differs for PCA and ICA. Cross-decomposition matching reveals only modest one-to-one spatial correspondence overall, yet …

    montana-tech Repository record for PROBING PROFICIENCY-RELATED NEURAL REPRESENTATIONS WITH PCA AND ICA (opens in a new tab)

  11. PROBING PROFICIENCY-RELATED NEURAL REPRESENTATIONS WITH PCA AND ICA

    … sweeps further show that proficiency-related signal is not tied to a single arbitrary number of components, but depends on representational scale, and that this scale differs for PCA and ICA. Cross-decomposition matching reveals only modest one-to-one spatial correspondence overall, yet …

    montana Repository record for PROBING PROFICIENCY-RELATED NEURAL REPRESENTATIONS WITH PCA AND ICA (opens in a new tab)

  12. Επίδραση των ελαστικών τάσεων επιταξίας στο μηχανισμό της μαγνητικής πόλωσης ανταλλαγής της πολυστρωματικής δομής [La2/3Ca1/3MnO3/La1/3Ca2/3MnO3]15

    … of the crystalline lattice. The RXS intensity difference signal exhibits a main-edge feature and a post-edge feature at 6.57 keV that scales linearly with temperature and the c/a ratio up to 80 K. The disappearance of the post-edge feature above 80 K(=TB) may signify a rearrangement of Mn-O-Mn …

    greece Repository record for Επίδραση των ελαστικών τάσεων επιταξίας στο μηχανισμό της μαγνητικής πόλωσης ανταλλαγής της πολυστρωματικής δομής [La2/3Ca1/3MnO3/La1/3Ca2/3MnO3]15 (opens in a new tab)

  13. Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision

    … fidelity, structural similarity index measure, difference signal-to-noise ratio, relative electron density drift, and radiomics deltas. Results: Across the evaluated cases, dose agreement was high and the gamma analysis passed. Hounsfield-unit mean absolute error was below 50 HU in many cases, …

    vcu Repository record for Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision (opens in a new tab)

  14. Analysis and comparison of three techniques for the compression of digital instrumentation data

    <p>When instrumentation signals are acquired and recorded digitally it is desirable to minimize the data storage space required. This thesis analyzes and compares three methods which were thought to be promising for compressing bandlimited smoothly varying instrumentation data with stationary …

    ut-knoxville Repository record for Analysis and comparison of three techniques for the compression of digital instrumentation data (opens in a new tab)

  15. Investigations Into Fragment Ligand Binding Using Quantitative STD and WaterLOGSY NMR Spectroscopy

    … Initially, it was shown that the amount of signal that could be produced from an STD NMR experiment could be dramatically increased by careful consideration of the selective saturation pulse. By systematically shortening the Gaussian pulse and positioning it at specific offset positions, it …

    kent Download PDF for Investigations Into Fragment Ligand Binding Using Quantitative STD and WaterLOGSY NMR Spectroscopy (opens in a new tab)

  16. A Neural Network Based Approach To Fault Detection In Industrial Processes

    … characteristics in the residual (or plant-model difference) signal without the necessity of constructing the types of filter used in more classical solutions. Initially, a class of feedforward neural network called the multilayer perceptron (MLP) is used to model mathematically simulated linear …

    plymouth Repository record for A Neural Network Based Approach To Fault Detection In Industrial Processes (opens in a new tab)

  17. MATLAB-Based Implementation of a Spatial Covariance Matching Spread Rendering Method

    … done in terms of colouration, interaural level difference (ILD), interaural coherence (IC), RMSE analysis over 836 source directions at different source spreads, and signal distortion error (SDE). The results indicate that EVD improves coherence matching and spatial diffuseness and OM yields a …

    chalmers Repository record for MATLAB-Based Implementation of a Spatial Covariance Matching Spread Rendering Method (opens in a new tab)

  18. Přímé sestavování genomových signálů ze sekvenace nanopórem

    Bakalářská práce se zabývá hledáním překryvů mezi signály ze sekvenace nanopórem z přístroje MinION verze R9. Teoretická část se věnuje metodám sestavování genomu – hladovým algoritmům, dále grafovým overlap-layout-consensus (OLC) a de Bruijnovým grafům. Novým přístupem je sekvenování nanopórem a …

    brno-tech Repository record for Přímé sestavování genomových signálů ze sekvenace nanopórem (opens in a new tab)