Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"differential phase contrast"”.

  1. Asymmetric Illumination X-ray Differential Phase Contrast Imaging

    … we present a novel, low-cost approach to x-ray phase contrast imaging (XPCI). This method, which we term asymmetric illumination x-ray phase contrast imaging (AIXPCI), is compatible with a broadband tabletop x-ray source in a conventional laboratory setting and utilizes an angular filtration …

    duke Repository record for Asymmetric Illumination X-ray Differential Phase Contrast Imaging (opens in a new tab)

  2. Advanced detection in Lorentz microscopy: pixelated detection in differential phase contrast scanning transmission electron microscopy

    … causes a shift of the simulated beam due to phase modulations. The results of the detection in both the simulation and experiment showed that cross-correlation based processing can efficiently separate the low spatial frequencies (from the in-plane magnetic induction), and high spatial …

    glasgow Download PDF for Advanced detection in Lorentz microscopy: pixelated detection in differential phase contrast scanning transmission electron microscopy (opens in a new tab)

  3. Measurement of transient transport of hyperosmotic agents across cell membranes and resulting optical clearing using differential phase contrast optical coherence microscopy

    … optical clearing. To accomplish this task, a differential phase contrast optical coherence microscope (DPC-OCM) is configured to permit quantitative spaciotemporal optical path length (OPL) imaging of biological cell specimens. The first application of DPC-OCM is analyzing the intracellular …

    texas Repository record for Measurement of transient transport of hyperosmotic agents across cell membranes and resulting optical clearing using differential phase contrast optical coherence microscopy (opens in a new tab)

  4. Characterisation of MFM tip stray fields using Lorentz electron tomography

    … tomography. The implementation of tomography and differential phase contrast (DPC) microscopy allows the stray field distribution in the half space in front of MFM tips to be measured with a spatial resolution of <30 nm and a field resolution of <2 mT. This information will allow the development …

    glasgow Download PDF for Characterisation of MFM tip stray fields using Lorentz electron tomography (opens in a new tab)

  5. IMPROVED LED ARRAY REFLECTANCE IMAGING FOR HIGH THROUGHPUT APPLICATIONS

    … patterns to capture high-quality darkfield and differential phase contrast images. However, its acquisition speed and signal to noise ratio are limited by the low backscattering of light off the surface of the specimen. The aim of this study is to enhance light delivery to the specimen by …

    jhu Repository record for IMPROVED LED ARRAY REFLECTANCE IMAGING FOR HIGH THROUGHPUT APPLICATIONS (opens in a new tab)

  6. Lorentz microscopy of chiral magnetic spin textures in multilayer thin films

    … using transport of intensity equation and differential phase contrast microscopy approaches.<br/><br/><i>Thesis is embargoed until 31 December 2026.</i>

    qu-belfast Repository record for Lorentz microscopy of chiral magnetic spin textures in multilayer thin films (opens in a new tab) Embargoed until 2026-12-31

  7. Micromagnetic simulation and Lorentz microscopy of curved ferromagnetic nanowires

    … Simulated experimental Fresnel mode and differential phase contrast (DPC) images were calculated and used in the quantification of the domain walls comparing magnetisation profiles to those from integrated induction. Finally, the effect of electrostatic phase on DPC and Fresnel image …

    qu-belfast Repository record for Micromagnetic simulation and Lorentz microscopy of curved ferromagnetic nanowires (opens in a new tab) Download PDF for Micromagnetic simulation and Lorentz microscopy of curved ferromagnetic nanowires (opens in a new tab)

  8. Micromagentic simulation and Lorentz microscopy of curved ferromagnetic nanowires

    … Simulated experimental Fresnel mode and differential phase contrast (DPC) images were calculated and used in the quantification of the domain walls comparing magnetisation profiles to those from integrated induction. Finally, the effect of electrostatic phase on DPC and Fresnel image …

    glasgow Repository record for Micromagentic simulation and Lorentz microscopy of curved ferromagnetic nanowires (opens in a new tab) Download PDF for Micromagentic simulation and Lorentz microscopy of curved ferromagnetic nanowires (opens in a new tab)

  9. Transmission Electron Microscopy of Organic Crystalline Material and Zeolites

    … of 17000 ± 8000 e-Å-2 at 300 kV. Integrated differential phase contrast, scanning transmission electron microscopy revealed the projected atomic positions of the zeolite in the [100]/[010] directions. The use of high-angle annular dark-field scanning transmission electron microscopy in …

    whiterose Download PDF for Transmission Electron Microscopy of Organic Crystalline Material and Zeolites (opens in a new tab)

  10. Combining Computational & Holographic Methods to Improve the Imaging Depth of Microscopy

    … in three primary ways. First, we present a differential phase contrast microscope that leverages light's polarisation properties and the optical memory effect to capture the phase delay caused by objects through significant scattering layers, equivalent to 135 micrometres of human skin. …

    dundee Repository record for Combining Computational & Holographic Methods to Improve the Imaging Depth of Microscopy (opens in a new tab) Embargoed until 2027-05-31

  11. The Study of Stray Magnetic Fields from Digital Recording Heads for Tape Applications

    … for tape applications was undertaken using the Differential Phase Contrast (DPC) mode of Lorentz microscopy and Magnetic Force Microscopy (MFM). Electron Beam Tomography (EBT), at Glasgow was derived from the DPC technique and this was carried out in a highly modified Philips CM20 (S)TEM; …

    glasgow Download PDF for The Study of Stray Magnetic Fields from Digital Recording Heads for Tape Applications (opens in a new tab)

  12. PHASE RETRIEVAL WITH 4D-STEM: LIMITS ON SENSITIVITY, RESOLUTION, AND SPEED

    … position, offering a significant enhancement in phase retrieval applications such as magnetic imaging and super-resolution ptychography. This thesis explores how to optimize sensitivity, resolution, and/or speed as a function of the number of detector pixels in 4D-STEM. One application is …

    cornell Repository record for PHASE RETRIEVAL WITH 4D-STEM: LIMITS ON SENSITIVITY, RESOLUTION, AND SPEED (opens in a new tab)

  13. A Study of Imaging Modes in the Scanning Transmission Electron Microscope

    … electron utilization is low in the standard phase contrast imaging mode in the scanning transmission electron microscope (STEM). This leads to serious difficulties when, for example, radiation sensitive material is under investigation. A significant improvement is achieved by using the …

    glasgow Download PDF for A Study of Imaging Modes in the Scanning Transmission Electron Microscope (opens in a new tab)

  14. Determination of physical and magnetic microstructure by STEM

    … within a thin film to be obtained (the differential phase contrast imaging mode). Furthermore it is seen that the very small source size of the field emission gun in the HB5 allows this information to be obtained with a high spatial resolution, and that the sequential nature of image …

    glasgow Download PDF for Determination of physical and magnetic microstructure by STEM (opens in a new tab)

  15. Single-shot X-ray Phase Contrast and Dark-field Imaging with a Single-mask Set-up

    … X-ray imaging, which relies on attenuation contrast, faces challenges in differentiating materials with similar attenuation coefficients, particularly in soft tissues. X-ray phase contrast imaging (XPCI) and dark-field (DF) imaging address this limitation by detecting phase shifts and …

    houston Repository record for Single-shot X-ray Phase Contrast and Dark-field Imaging with a Single-mask Set-up (opens in a new tab) Embargoed until 2026-12-01

  16. TEM studies of the crystal growth of indanthrone pigments

    … electron energy loss spectroscopy) and DPC (differential phase contrast) studies took place on the VG HB5 STEM (scanning transmission electron microscope). In addition to these studies, x-ray diffraction and surface area analysis techniques were employed.The low magnification CTEM work gave …

    glasgow Download PDF for TEM studies of the crystal growth of indanthrone pigments (opens in a new tab)

  17. Precision bounds in localization microscopy

    … Scattering Microscopy (QSCAT), a label-free phase imaging technique designed for in situ materials characterization. The system employs a digital light processing (DLP) device and LED illumination to project half pupil patterns onto the back aperture of an objective, enabling differential …

    colostate Repository record for Precision bounds in localization microscopy (opens in a new tab)

  18. Microcharacterisation of Halogenated Copper Phthalocyanines Using Transmission Electron Microscopy

    … from perfect crystallinity. The modified differential phase contrast imaging technique allowed simultaneous topographic and lattice images to be recorded from the same area, distinguishing aggregates which had not been broken down by the pigmentation process. The chemical composition of …

    glasgow Download PDF for Microcharacterisation of Halogenated Copper Phthalocyanines Using Transmission Electron Microscopy (opens in a new tab)

  19. Characterisation of micron sized ferromagnetic structures fabricated by focussed ion beam and electron beam lithography

    … are investigated by the Fresnel imaging and the differential phase contrast modes of Lorentz microscopy. A programme known as object orientated micromagnetic framework (OOMMF) is used to model the magnetic properties of such structures.

    glasgow Download PDF for Characterisation of micron sized ferromagnetic structures fabricated by focussed ion beam and electron beam lithography (opens in a new tab)

Page 1 of 2