Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 103 for “"digital volume correlation"”
-
High performance digital volume correlation
… improvements to a three-dimensional (3D) digital volume correlation (DVC) algorithm, which measures displacement and strain fields throughout the interior of a material. Our goal is to perform DVC with resolution comparable to that achieved in 2D digital image correlation, in time that is …
-
Investigation of Composite Materials Using Digital Volume Correlation
… field internal displacement and strain field. Digital Volume Correlation (DVC) is a measurement technique which generates a 3D displacement and strain field for the sample under loading. Fused filament fabrication (FFF) and hybrid braided composites has limited research to understand the …
-
Investigation of Advanced Material Through Digital Volume Correlation Measurement Techniques
… are often complex and difficult to predict. Digital volume correlation (DVC) offers a novel method for the deformation analysis of composite structures. Through the utilization of micro-computed tomography datasets can be obtained and utilized to visualize three-dimensional dataset for DVC. …
-
Identification of corneal mechanical properties using optical tomography and digital volume correlation
Ce travail présente une méthodologie efficace pour mesurer le champ de déformation total en 3-D des tissus mous semi-transparents et diffusant la lumière, tels que la cornée de l'œil vertébré. Cela a été obtenu en utilisant la tomographie par cohérence optique couplée avec la corrélation volumique …
-
Image-Based Fracture Mechanics with Digital Image Correlation and Digital Volume Correlation
… with the microstructure and stress fields. Digital Image Correlation (DIC) and Digital Volume Correlation (DVC) have been widely accepted and routinely used to measure full-field displacements in many areas of solid mechanics, including fracture mechanics. However, current practise for the …
-
Error estimation in whole bone microstrain measurement when using digital volume correlation
… changes within the bone micro-architecture. Digital volume correlation (DVC) is a mathematical technique used to determine strain within the bone volume, by tracing the dislocation of a pattern between the 3-dimensional images. Uncertainty in the microstrain calculated arises due to …
-
A protocol for physiological mechanical testing of cortical bone using digital volume correlation
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2022-04-06 without embargo terms
-
The Application of Digital Volume Correlation Bone Strain Measurements in the Osteoarthritic Glenohumeral Joint
… investigates the accuracy and precision of digital volume correlation measurements derived from micro-computed tomography imagery of interfaces in the upper extremity of clinical relevance, namely, the implant-cement-bone interface of glenoid implants used in total shoulder arthroplasties …
-
Particulate composite material internal deformation measurements using x-ray microtomography and digital volume correlation
… of particulate sizes and often high particulate volume fractions (65%-95%). Examples of these are, explosives and rocket propellants for defense and aerospace applications, asphalt concrete materials civil engineering applications and ceramic/ceramic thermal barrier coatings for turbine engines. …
-
Digital volume correlation as a method for estimating load-induced deformations in the human spine
Digital volume correlation (DVC) is a computational tool used to measure a 3D displacement field between a pair of 3D images (from, for example, magnetic resonance imaging (MRI), computed tomography (CT), ultrasound, etc.). Studies in biomechanics have used DVC to quantify deformations in cells, …
-
Investigation of damage initiation in carbon fibre reinforced polymer composites using synchrotron radiation computed tomography and digital volume correlation
… initiation. Complementary techniques such as Digital Volume Correlation (DVC) and image segmentation have been used to analyse the strains associated with crack initiation in cross ply laminates loaded and imaged in 3D in situ. (The use of these techniques, to investigate damage initiation in …
-
Translation of an OCT-Based Digital Volume Correlation Framework from Human to Rat Eyes for Detecting IOP-Induced Optic Nerve Head Deformation
… Optical coherence tomography combined with digital volume correlation (OCT-DVC) has been used in human eyes to quantify ONH deformation and strain in vivo, but its translation to the rat eye has not been established. The objective of this thesis was to evaluate whether a human OCT-DVC …
-
Inverse approaches for the mechanics of 3D-printed surgical phantoms : Identification and kinematic analysis from intraoperative imaging via projection-based digital volume correlation
Les techniques récentes de fabrication additive ont permis le développement de matériaux imitant les tissus biologiques, notamment utilisés pour produire des modèles anatomiques. Dans le contexte de la Réparation EndoVasculaire d'Anévrisme (EVAR), un protocole clinique est déployé pour permettre …
-
Assisting digital volume correlation with mechanical image-based modeling : application to the measurement of kinematic fields at the architecture scale in cellular materials
La mesure de champs de déplacement et de déformation aux petites échelles dans des microstructures complexes représente encore un défi majeur dans le monde de la mécanique expérimentale. Ceci est en partie dû aux acquisitions d'images et à la pauvreté de la texture à ces échelles. C'est notamment …
-
Validation of Subject Specific Computed Tomography-based Finite Element Models of the Human Proximal Tibia using Full-field Experimental Displacement Measurements from Digital Volume Correlation
… predict internal bone mechanics (displacement). Digital volume correlation (DVC) can measure internal bone displacements and has been used to validate FE models of bone; though, its use has been limited to small specimens. The objectives of this study were to 1) establish a methodology for …
-
Comparison of proximal femur deformations, failures and fractures in quasi-static and inertially-driven simulations of a sideways fall from standing : an experimental study utilizing novel fall simulation, digital image correlation, and development of digital volume correlation techniques
… In study 2, the same bones were compared using digital image correlation to examine bone strains on the anterior-superior femoral neck. In study 3, two cohorts of bones were loaded to failure, one at constant displacement rate and the other in the impact fall simulator. Initial failure …
-
Investigation of the high-temperature mechanical behaviour of oxide-oxide ceramic-matrix composites
… with in situ X-ray computed microtomography and digital volume correlation were explored. Subsequently, residual stresses were quantified using photoluminescence piezospectroscopy.<br/>Materials with different sintering temperatures based on Nextel<sup>TM</sup> 720 fibres displayed average …
-
The use of synchrotron x-ray micro computed tomography to study the failure mechanisms of thermal barrier coatings
… X-ray microtomography (SX μCT) coupled with digital volume correlation (DVC). The forcebalance method relates the creep in bondcoats of precision-machined cylindrical micro-specimens to the stress acted on the bondcoat by the TGO. These precisionmachined specimens were volumetrically imaged …
-
In vitro mechanical characterization of the human natural and treated vertebrae
… different measurement methods (strain gauges and digital volume correlation) at different dimensional scales was adopted to investigate natural and augmented vertebrae during non-destructive and destructive testing. The effects of prophylactic augmentation were investigated for the first time …
Page 1 of 6