Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"diode detector"”.

  1. DESIGN AND CONSTRUCTION OF A SILICON SCHOTTKY DIODE DETECTOR FOR SINGLE PROTON COUNTING AT THE MCMASTER MICROBEAM LABORATORY

    … there are presently no commercially available detectors for this application, which necessitates the need for a new detector. Following literature research, a 10 μm thin Schottky diode detector was selected as the most appropriate type of detector for the setup at McMaster. The design of the …

    mcmaster Repository record for DESIGN AND CONSTRUCTION OF A SILICON SCHOTTKY DIODE DETECTOR FOR SINGLE PROTON COUNTING AT THE MCMASTER MICROBEAM LABORATORY (opens in a new tab)

  2. Small field dosimetry: experimental methods and Monte Carlo simulation in small field radiation therapy dosimetry

    … are for accurate small field relative dosimetry. Diode detector selection and experimental techniques were evaluated. EGSnrc Monte Carlo simulations were used to predict diode detector dosimetric parameters and assist in interpreting measured data. An emerging scintillator based detector …

    whiterose Download PDF for Small field dosimetry: experimental methods and Monte Carlo simulation in small field radiation therapy dosimetry (opens in a new tab)

  3. Terahertz quantum cascade laser application in local oscillator development

    … electrical and thermal performance. Next, the detector (Schottky diode detector) use in the application was investigated in terms of heterodyne detection and detection calibration. The heterodyne signal from the Schottky diode detector was used to study a Fabry–Perot (FP) QCL, whose …

    whiterose Download PDF for Terahertz quantum cascade laser application in local oscillator development (opens in a new tab)

  4. Negatively Biased Field Effect Transistor Used As a Microwave Detector

    The majority of' today's microwave detectors are based on microwave diodes. The research presented in this thesis develops the theory of a new, more sensitive detector based on a negatively biased microwave FET. The theory construction of was then applied to the design and a FET microwave detector. …

    marquette Repository record for Negatively Biased Field Effect Transistor Used As a Microwave Detector (opens in a new tab)

  5. In-Vivo Radiation Diode Dosimetry for Therapeutic Photon Beams

    In-vivo dosimetry with diode detectors is used in radiation therapy as a quality assurance tool. The diode sensitivity under radiation depends upon temperature, dose rate and SDD (source-to-detector distance), field size, beam angle, and energy. This dissertation presents the first systematic and …

    usf Repository record for In-Vivo Radiation Diode Dosimetry for Therapeutic Photon Beams (opens in a new tab)

  6. Fabrication process and characteristics of a silicon strip detector

    … and possible uses of semiconductor solid state detectors in nuclear physics are briefly discussed. The theory of solid state detectors is discussed with emphasis on the silicon PIN diode detector. A fabrication process for silicon surface barrier position sensitive solid state detectors has been …

    ubc Repository record for Fabrication process and characteristics of a silicon strip detector (opens in a new tab) Download PDF for Fabrication process and characteristics of a silicon strip detector (opens in a new tab)

  7. Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation platform

    … and dose profiles using an ion chamber, diode detector, and radiochromic film are used as reference measurements for the model. The model shows agreement with the measured data with greater than 90% of points passing a 3%/1mm gamma comparison, with the exception of smaller field sizes in …

    calgary Repository record for Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation platform (opens in a new tab)

  8. Characterization of p-type silicon semiconductor detectors for use in in vivo dosimetry

    The response of a p-type diode detector for use in patient dose monitoring in photon and electron fields was evaluated for a number of commonly-encountered clinical parameters. Effects of energy, field size, source-to-surface distance, presence of beam modifiers, beam orientation, and temperature …

    unlv Repository record for Characterization of p-type silicon semiconductor detectors for use in in vivo dosimetry (opens in a new tab) Download PDF for Characterization of p-type silicon semiconductor detectors for use in in vivo dosimetry (opens in a new tab)

  9. An analysis of a narrow-band frequency modulation instrumentation problem

    … phase discriminator to be used as a synchronous detector of a very narrow-band FM wave in noise. Experimental work is. reported which indicates the superiority of this method of detection over a conventional PM discriminator. A comparison is made of the effect upon limiter operating point of two …

    nps Repository record for An analysis of a narrow-band frequency modulation instrumentation problem (opens in a new tab)

  10. Six-port wireless receiver architectures

    … and dual-tone linearization of on­board diode detector are also proposed.<br/><br/>A modelling strategy for each of the lumped elements required to construct a six-port digital receiver using RFCMOS technology has been studied. Novel models and design rules for CMOS capacitor and inductor …

    qu-belfast Repository record for Six-port wireless receiver architectures (opens in a new tab) Download PDF for Six-port wireless receiver architectures (opens in a new tab)

  11. Hybrid micro-LED devices enabled by elastomeric micro-transfer printing

    … of hybrid micron-sized light emitting diode (micro-LED) devices by elastomeric micro-transfer printing. The main body of this work is divided into the development of dual-colour micro-LED devices and the integration of micro-LEDs with control electronics, mainly for optical …

    strathclyde Repository record for Hybrid micro-LED devices enabled by elastomeric micro-transfer printing (opens in a new tab)

  12. Design and Optimization of Broadband Planar Baluns and Dipole Antennas

    … In this thesis, a compact shielded balun, a diode detector, and a broadband sleeve dipole are modeled and implemented resulting in optimal devices presenting accurate operation. The balun circuit is designed to meet the need for a miniaturized device with broadband application. A balun is a …

    usf Repository record for Design and Optimization of Broadband Planar Baluns and Dipole Antennas (opens in a new tab)

  13. Investigation of the Rectenna Concept for Millimeter Wave Applications

    … work a 2.5GHz slot antenna, a 2.5GHz Schottky diode detector, a CPW-to-Microstrip transition, a fully integrated Rectenna element, and a 94GHz slot antenna were designed, fabricated, and tested. Results on the performance of the devices show a great deal of correlation between the simulated and …

    usf Repository record for Investigation of the Rectenna Concept for Millimeter Wave Applications (opens in a new tab)

  14. Intensity based multispectral terahertz polarimetric imaging using frequency-selective surfaces

    … measurements is developed using Schottky diode detector and experimental results closely followed the expected simulation results. By acquiring intensity images at multiple analyzer orientations and discrete frequencies, the system enables direct extraction of polarization metrics such as …

    ets-quebec Download PDF for Intensity based multispectral terahertz polarimetric imaging using frequency-selective surfaces (opens in a new tab)

  15. Digital predistortion linearization methods for RF power amplifiers

    … of the RF predistorter, are analog envelope detectors that are required for generating the control signals for the digital circuitry. Three commonly used detection methods, power, linear diode and logarithmic detector, are compared. The linear diode detector was shown to be the most …

    aalto Repository record for Digital predistortion linearization methods for RF power amplifiers (opens in a new tab)

  16. Comprehensive Investigation of Energy Fluence Spectra and MLC Modeling Parameters and their Effects on Dose Calculation Accuracy in Pinnacle

    … square MLC and jaws defined fields. A Sun-Point diode detector was used in the measurement of the output factors for its accurate precision at small geometries. In addition, a GAFCHROMIC EBT2 film dosimetry was used in the measurement of the MLC abutment leakage.</p> <p>Our new model shows …

    mcmaster Repository record for Comprehensive Investigation of Energy Fluence Spectra and MLC Modeling Parameters and their Effects on Dose Calculation Accuracy in Pinnacle (opens in a new tab)

  17. Extratos e fases de partição de coccoloba alnifolia: potencial antioxidante, imunomodulador e cicatrizante in vitro

    … liquid chromatography coupled to a diode detector (HPLC-DAD). In addition, these fractions were characterized here for their antioxidant potential by using in vitro assays. It was observed that both have antioxidant potential. The FB, however, displayed higher antioxidant potential …

    brazil-ufrn Repository record for Extratos e fases de partição de coccoloba alnifolia: potencial antioxidante, imunomodulador e cicatrizante in vitro (opens in a new tab)

  18. Practical Real-time Permanent Magnet Energy Spectrometer using a Diode Array for Therapeutic Electron Beam Tuning and Quality Assurance

    … MapCHECK® PC boards, providing two interlaced diode arrays. Detector response, Rmeas(zdiode) versus diode position zdiode, was extracted from raw diode array readings, correcting for diode sensitivity and other factors. Using Monte Carlo (MC) computed, monoenergetic detector response functions, …

    lsu-thes Repository record for Practical Real-time Permanent Magnet Energy Spectrometer using a Diode Array for Therapeutic Electron Beam Tuning and Quality Assurance (opens in a new tab)

  19. Monte Carlo modeling of an x-ray fluorescence detection system by the MCNP code

    … source, a Pb beam collimator, and a CdTe photodiode detector. In order to optimize and facilitate future experimental tasks, a Monte Carlo model of the detection system has been created by using the MCNP5 code. Specifically, the model included an x-ray source, a Pb collimator, a CdTe detector, …

    gatech Repository record for Monte Carlo modeling of an x-ray fluorescence detection system by the MCNP code (opens in a new tab)

Page 1 of 2