Showing 1 to 20 of 84 for “"displacement control"”.

  1. Stopper-Bearing System – A Solution to Displacement Control of Bridge Decks

    … earthquakes have resulted in large horizontal displacements on the superstructure that have lead to unseating of bridge spans and unexpected pounding forces that damaged critical components such as bearings and anchor bolts. To this end, a new bearing system, referred to as a stopperbearing …

    tamu Repository record for Stopper-Bearing System – A Solution to Displacement Control of Bridge Decks (opens in a new tab)

  2. Design and Fabrication of a Force-Displacement Control Mechanism for Bone-Surgical Tool Testing

    … and rigorous testing, resulting in a versatile control system capable of assessing various orthopedic tools, including bone drills, saws, burrs, and power handpieces. Orthopedic surgical procedures (which include cutting and/or drilling into bone) often need to be performed on bones for faster …

    gsu Repository record for Design and Fabrication of a Force-Displacement Control Mechanism for Bone-Surgical Tool Testing (opens in a new tab)

  3. Modeling, simulation, and stability of a hydraulic load-sensing pump system with investigation of a hard nonlinearity in the pump displacement control system

    … (LS) pumps utilize a hydro-mechanical control system designed to regulate the pressure difference, or margin pressure, between the inlet and outlet of a flow control valve. With a constant margin pressure, predictable flow control and improved efficiency can be achieved by controlling …

    missouri Repository record for Modeling, simulation, and stability of a hydraulic load-sensing pump system with investigation of a hard nonlinearity in the pump displacement control system (opens in a new tab)

  4. Development of a micro-depth sensing indentation technique with constant load control

    … of the load-depth curve. The accurate load and displacement measurement as well as high precision position control of the indenter are needed to achieve the required measurement resolution. The application of PZT actuator is often used to perform the indentation experiment. However, conventional …

    wvu Repository record for Development of a micro-depth sensing indentation technique with constant load control (opens in a new tab)

  5. Understanding the Complex Interplay of Factors in Rail Buckling: A Finite Element Approach

    … extends the model's development by including the displacement-control based solving algorithm, as well as modifying the tie-ballast interface resistance formulation, and restructuring the variational formulation of the governing differential equations. The key focus of this research is to …

    tamu Repository record for Understanding the Complex Interplay of Factors in Rail Buckling: A Finite Element Approach (opens in a new tab) Embargoed until 2027-05-01

  6. Biomechanical biomarkers of cancer

    … FEBio was used to create both force and displacement control confined compression tests of tissues modelled by collagen hydrogels. The tissue models contained a 'tumour' layer and the effects of varying the stiffness parameters of this 'tumour' layer were investigated. Any change in …

    strathclyde Repository record for Biomechanical biomarkers of cancer (opens in a new tab)

  7. Ανάπτυξη καινοτόμου συστήματος ελέγχου υβριδικών δοκιμών δύσκαμπτων κατασκευών υπό σεισμική διέγερση

    … significant difficulties when relying on the displacement control of hydraulic actuators. The reason being that in hybrid tests the restoring force in each step is used to calculate the displacement of the next step; therefore a potential error in the calculation (intrinsic in the case of …

    greece Repository record for Ανάπτυξη καινοτόμου συστήματος ελέγχου υβριδικών δοκιμών δύσκαμπτων κατασκευών υπό σεισμική διέγερση (opens in a new tab)

  8. DEVELOPMENT OF INNOVATIVE MULTICOMPARTMENT MICROFLUIDIC PLATFORMS TO INVESTIGATE TRAUMATIC AXONAL INJURY

    … compression platform. I successfully developed a displacement control injury device and demonstrated displacement control as a proof of principle. Further development of these microfluidic platforms will significantly contribute to the field of basic neuroscience, neurobiology, and biomedical …

    jhu Repository record for DEVELOPMENT OF INNOVATIVE MULTICOMPARTMENT MICROFLUIDIC PLATFORMS TO INVESTIGATE TRAUMATIC AXONAL INJURY (opens in a new tab)

  9. Analysis of Instabilities in Microelectromechanical Systems, and of Local Water Slamming

    … respect to time. For the static problem, the displacement control and the pseudo-arc length continuation (PALC) methods are used to obtain the bifurcation curve of arch's deflection versus the electric potential. The displacement control method fails to compute arch's asymmetric deformations …

    vt Repository record for Analysis of Instabilities in Microelectromechanical Systems, and of Local Water Slamming (opens in a new tab)

  10. Residual Capacity of Blast-Damaged Reinforced Concrete Columns

    … capacity test program. Four (4) were undamaged control samples while the remaining nine (9) survived the field tests carried out by Siba (2014). The residual capacity tests were carried out by the applying axial force in a load control mode then lateral force in a displacement control mode. The …

    carleton Repository record for Residual Capacity of Blast-Damaged Reinforced Concrete Columns (opens in a new tab)

  11. Control of the Mechanical Properties of the Synthetic Anterior Longitudinal Ligament and its Effect on the Mechanical Analogue Lumbar Spine Model

    … the stiffness and deformation at toe were controlled in a repeatable manner. Five analogue spine models, with three different Anterior Longitudinal Ligament (ALL) stiffness configurations, were tested in bending and compression using displacement control in a MTS load frame. The bending …

    ku Repository record for Control of the Mechanical Properties of the Synthetic Anterior Longitudinal Ligament and its Effect on the Mechanical Analogue Lumbar Spine Model (opens in a new tab)

  12. Determining the efficacy of Poloxamer 188 (P188) in meniscal damage prevention

    … interface for a custom bioreactor capable of displacement control for precise loading of meniscal explants to physiological and supraphysiological strains; 2) determine the efficacy of P188 in mitigating meniscal tissue damage through cell viability, mechanical data and histological analysis.

    colostate Repository record for Determining the efficacy of Poloxamer 188 (P188) in meniscal damage prevention (opens in a new tab)

  13. Force control of a highly inertial specimen.

    Many servo-hydraulic control applications require high bandwidth realtime force tracking. Some specimen dynamics greatly limit the force bandwidth obtainable with standard PID loops. In these cases, the force control bandwidth is much lower than its position control counterpart. When the specimen …

    umn Repository record for Force control of a highly inertial specimen. (opens in a new tab)

  14. Effect of diet properties on the degradation of cartilage in mandibular symphysis

    … properties, i.e. soft-use diet, medium-use (control) diet and hard-use diet, have been studied. To investigate the viscoelastic response of the tissue materials, load control and displacement control nanoindentation tests were performed, and the displacement-time data and the load-time data …

    missouri Repository record for Effect of diet properties on the degradation of cartilage in mandibular symphysis (opens in a new tab)

  15. In-plane behaviour of differently refurbished timber floors

    … of these types of reinforcement experimental displacement control tests were carried out. They were monotonic and cyclic tests of specimens with dimensions 2x1 m and 5x4 m, with and without perimeter tie-beams. The same tests were numerically reproduced and a numeric model of simple …

    trento Repository record for In-plane behaviour of differently refurbished timber floors (opens in a new tab)

  16. Effect of Soft Ground Tunneling-Induced Displacements on Railway Embankments

    … Consequently, the alleviation of ground surface displacement is of great significance to ensure the safety of both railway operations and tunnel construction. This thesis is a fundamental study of the surface displacements due to the construction of both shallow (near-surface) and deep (away from …

    concordia Download PDF for Effect of Soft Ground Tunneling-Induced Displacements on Railway Embankments (opens in a new tab)

  17. Effect of Clay Addition on Mode II Interlaminar Fracture Toughness and Flexural Fatigue Behavior of Glass/Epoxy Composites

    … (PC) tests respectively. Fatigue was done in displacement control mode. The results indicated that the crack initiated earlier for regular samples than the modified ones. First, the rate of crack propagation was fast then, it became slow until achieved to the stable condition. At 2wt% …

    concordia Download PDF for Effect of Clay Addition on Mode II Interlaminar Fracture Toughness and Flexural Fatigue Behavior of Glass/Epoxy Composites (opens in a new tab)

  18. Elasto-plastic finite element for pipelines.

    … forces. The analysis is implemented using the displacement control scheme in order to capture the peak point of the load deformation response without numerical difficulty. The normality condition concept in conjunction with the yield hyper-surface at stress resultant level is used to …

    ottawa-retro Repository record for Elasto-plastic finite element for pipelines. (opens in a new tab)