Showing 1 to 20 of 21 for “"dose accumulation"”.

  1. Localized bladder dose accumulation in multi-fraction cervical cancer brachytherapy

    … (EBRT) combined with image-guided high-dose-rate (IG HDR) intracavitary brachytherapy (ICBT). IG HDR-ICBT is a relatively new, advanced form of brachytherapy treatment planning and delivery that still relies largely on dose criteria based either on clinical experience using older …

    ubc Repository record for Localized bladder dose accumulation in multi-fraction cervical cancer brachytherapy (opens in a new tab) Download PDF for Localized bladder dose accumulation in multi-fraction cervical cancer brachytherapy (opens in a new tab)

  2. Deformable Dose Accumulation Evaluation with Spatial Corrective Guidance Using Subregion Analysis

    … therapy increasingly relies on cumulative dose evaluation across treatment courses, both for adaptive replanning and for re-irradiation, which involves roughly 20% of patients. These workflows require deforming prior dose onto a new CT, but current validation of deformable dose accumulation …

    jhu Repository record for Deformable Dose Accumulation Evaluation with Spatial Corrective Guidance Using Subregion Analysis (opens in a new tab)

  3. Novel Techniques for Determining and Assessing Radiotherapy Margins

    … More complex strategies using deformable dose accumulation are expected to reflect the subtleties of realistic treatment scenarios, but current methods are time-consuming and limited to smooth contours. In practice, PTV margins are generally selected based on published experiences and are …

    calgary Repository record for Novel Techniques for Determining and Assessing Radiotherapy Margins (opens in a new tab)

  4. Development of Advanced Mr-Guided Adaptive Radiation Therapy Methods For Head & Neck Cancers On The 1.5T Mr-Linac

    … potential for advanced ART strategies such as dose-optimized ART, in which the treatment plan is optimized based on the accumulated dose over previous fractions, or biological image-guided ART, in which the plan is adapted based on individual tumor response as measured through quantitative …

    uthsc Repository record for Development of Advanced Mr-Guided Adaptive Radiation Therapy Methods For Head & Neck Cancers On The 1.5T Mr-Linac (opens in a new tab)

  5. DISCRETE-EVENT SIMULATION PROCESS MODEL FOR THE PYROCHEMICAL PROCESSING OF PLUTONIUM AT LOS ALAMOS NATIONAL LABORATORY

    … material throughput, equipment requirements, and dose accumulation of the pyrochemical metal production operations. The process model represents the cause-and-effect relationships between the pyrochemical processing environment and the process constraints, including criticality limitations, …

    utk-theses Repository record for DISCRETE-EVENT SIMULATION PROCESS MODEL FOR THE PYROCHEMICAL PROCESSING OF PLUTONIUM AT LOS ALAMOS NATIONAL LABORATORY (opens in a new tab)

  6. Applications of x-ray computed tomography polymer gel dosimetry

    … complex treatments and more advanced radiation dose calculations. To ensure the effectiveness and safety of modern radiation therapy, dose measurement tools must improve to accommodate these advances. X-ray computed tomography (CT) polymer gel dosimetry is a unique type of dosimeter that has …

    uvic Repository record for Applications of x-ray computed tomography polymer gel dosimetry (opens in a new tab)

  7. Strategies for adaptive radiotherapy: towards clinically efficient workflows

    … for interfraction treatment monitoring through dose accumulation following DIR. The robustness of several treatment methods to observable anatomical changes were investigated, highlighting cases whereby substantial dosimetric consequences may arise. Offline ART workflows were explored, …

    birmingham Download PDF for Strategies for adaptive radiotherapy: towards clinically efficient workflows (opens in a new tab)

  8. Improving Dose-Response Correlations For Locally Advanced Nsclc Patients Treated With Imrt Or Pspt

    … patients remains below 28 months. Higher tumor dose has been found to increase survival but also a higher rate of radiation pneumonitis (RP) that affects breathing capability. In fear of such toxicity, less-aggressive treatment plans are often clinically preferred, leading to metastasis and …

    uthsc Repository record for Improving Dose-Response Correlations For Locally Advanced Nsclc Patients Treated With Imrt Or Pspt (opens in a new tab)

  9. Deformable Dose Reconstruction to Optimize the Planning and Delivery of Liver Cancer Radiotherapy

    … results in improved control with higher tumor doses and minimized normal tissues doses. A margin of normal tissue around the tumor requires irradiation however to account for treatment delivery uncertainties. Daily image-guidance allows targeting of the liver, a surrogate for the tumor, to …

    toronto-retro Repository record for Deformable Dose Reconstruction to Optimize the Planning and Delivery of Liver Cancer Radiotherapy (opens in a new tab)

  10. Cooperativity: Physiologic Cornerstone and Emerging Therapeutic Design Principle

    … employ inert materials and rely on passive accumulation for tissue targeting and diffusion for drug release. Early clinical studies show these nanodrugs have not delivered the anticipated impact on therapy. Inspired by nature, this dissertation explores a design principle that incorporates …

    utswmed Repository record for Cooperativity: Physiologic Cornerstone and Emerging Therapeutic Design Principle (opens in a new tab)

  11. Fast Monte Carlo Simulations for Quality Assurance in Radiation Therapy

    … considered to be the most accurate method for dose calculation in radiation therapy. However, it suffers from the low simulation efficiency (hours to days) and complex configuration, which impede its applications in clinical studies. The recent rise of MRI-guided radiation platform (e.g. …

    wustl Repository record for Fast Monte Carlo Simulations for Quality Assurance in Radiation Therapy (opens in a new tab)

  12. Motion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT)

    … radiation therapy (SBRT) characterizing as high dose in each fraction and few fraction number requires higher accuracy for tumor localization. For organs influenced by the respiration, respiration induced motion becomes the principal cause for tumor localization uncertainty and four dimensional …

    utswmed Repository record for Motion Estimation and Motion-Compensated Reconstruction for Four-Dimensional Cone Beam Computed Tomography (4D-CBCT) (opens in a new tab)

  13. An oral physiologically-based pharmacokinetic model to predict drug absorption and disposition of vismodegib

    … PK behavior in humans. For a 150 mg oral dose, accumulation was roughly 5-fold lower than expected and steady-state was reached in 7-14 days, rather than the 60 days predicted under linear PK assumptions. Furthermore, the 150 mg, 270 mg, and 540 mg dose cohorts in clinical trials displayed …

    ubc Repository record for An oral physiologically-based pharmacokinetic model to predict drug absorption and disposition of vismodegib (opens in a new tab) Download PDF for An oral physiologically-based pharmacokinetic model to predict drug absorption and disposition of vismodegib (opens in a new tab)

  14. Patients undergoing recurrent computed tomography procedures: indications, risks and exposure assessment /

    … has led to an increase in the total radiation dose among certain patients. While a single CT scan is usually a low-risk procedure that is clinically justified, the repeated imaging can lead to cumulative effective doses (CED) that overreach the thresholds corresponding to the increased cancer …

    vilnius Repository record for Patients undergoing recurrent computed tomography procedures: indications, risks and exposure assessment / (opens in a new tab)

  15. Optimization of Lead Spectinamide Compounds as Novel Anti-tuberculosis Agents with a Pharmacometric Approach

    … epidermis and other surface tissue. In multiple-dose accumulation studies, the Cmax of radiolabeled compound after the 1st dose and the 8th dose of twice-daily dosing regimen was similar: 3.39µCi/mL and 3.55µCi/mL, suggesting no relevant accumulation of parent drug and metabolites. The …

    tenn-hsc Repository record for Optimization of Lead Spectinamide Compounds as Novel Anti-tuberculosis Agents with a Pharmacometric Approach (opens in a new tab)

  16. Radiation Induced Degradation Pathways for Poly (Methyl Methacrylate) and Polystyrene Polymers as Models for Polymer Behavior in Space Environments

    … and predicting and simulating the total absorbed dose and ionization for long term space missions are presented herein. This investigation evaluates cross-linking, main-chain scission and elimination products in a linear series of narrowly dispersed poly(methyl methacrylate) (PMMA) and polystyrene …

    usf Repository record for Radiation Induced Degradation Pathways for Poly (Methyl Methacrylate) and Polystyrene Polymers as Models for Polymer Behavior in Space Environments (opens in a new tab)

  17. Magmatic arcs of Papua New Guinea: insights into the late Cenozoic tectonic evolution of the northern Australian plate boundary

    … matrix effects related to differential alpha dose accumulation and limitations on instrumental precision with an associated error threshold of 5% for a determined age. This makes LA-ICP-MS U-Pb dating a useful tool in regional studies of this nature. The Late Cenozoic tectonic evolution of …

    jamescook Download PDF for Magmatic arcs of Papua New Guinea: insights into the late Cenozoic tectonic evolution of the northern Australian plate boundary (opens in a new tab)

  18. Clinical and Research Applications of 3D Dosimetry

    … algorithms prior to clinical implementation in dose deformation and accumulation calculations.</p><p>3D Remote Dosimetry: The feasibility of remote high-resolution 3D dosimetry with the PRESAGE®/Optical-CT system was investigated using two nominally identical optical-CT scanners for 3D dosimetry …

    duke Repository record for Clinical and Research Applications of 3D Dosimetry (opens in a new tab)

Page 1 of 2