Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 20 for “"dose coefficients"”.
-
Room radiation dose coefficients for external exposure
… a building room is radiologically contaminated, dose rate coefficients are needed to estimate the dose rate to the occupants. One’s position in the room, whether in the center of the room or the corner, could have an effect on dose rate. The Environmental Protection Agency (EPA) published in …
-
Local dose coefficients for radionuclide contamination in wounds
The objective of this research is to create local dose coefficients for radionuclide contaminated wounds to accompany dose coefficients obtained by Oak Ridge Institute for Science and Education looking at whole body effects of radionuclide intake from wounds. These dose coefficients can be used to …
-
Dose coefficients for radionuclides produced in a spallation neutron source
Internal and external dose coefficient values have been calculated for 14 anthropogenic radionuclides which are not currently presented in Federal Guidance Reports No. 11, 12, and 13 or Publications 68 and 72 of the International Commission on Radiological Protection. Internal dose coefficient …
-
Investigation and Calculation of Dose Coefficients for Radionuclides Produced in a Spallation Neutron Source Using the ENSDF and NUBASE Nuclear Databases
Dose coefficients are useful for risk assessment during the design and siting of accelerator-driven nuclear facilities including the Spallation Neutron Source. There are seventy-two radionuclides with half-lives equal to or greater than one minute that will be produced by the spallation of a …
-
Uncertainty Analysis in ICRP 66 Human Respiratory Tract Model for Consequence Management Data Products
… a software called REDCAL (Radiation Exposure Dose Calculator) was developed in Python to handle statistically sampled parameters to compute the radiation dose from radionuclides of concern for emergency response planners. REDCAL handles the inhalation of radioactive particles and subsequent …
-
Dosimetry-based Assessment of Radiation-associated Cancer risk for \(^9\)\(^9\)\(^m\)Tc-MAG3 Scans in Infants and Optimization of Administered Activities for \(^6\)\(^8\)Ga-labelled Peptides in Children and Adolescents
… Patient-specific time-integrated activity coefficients were obtained by integrating the organ-specific time-activity curves. Absorbed and effective dose coefficients for each patient were assessed with OLINDA/EXM for the provided newborn and 1-year-old phantom. Based on absorbed dose …
-
Assessing internal contamination levels for fission product inhalation using a portal monitor
… MCNP model--the Adipose Male and Child phantoms. Dose and Risk Calculation software (DCAL) provided inhalation biokinetic data that were applied to the output of the MCNP modeling to determine the radionuclide concentrations in each organ as a function of time. For each phantom type, these data …
-
Maximum Hypothetical Accident Analysis for the Natura Resources Molten Salt Research Reactor at Abilene Christian University
… Regulatory Guide 1.145, which was coupled with dose coefficients from Federal Guidance Reports 11 and 12 and the ICRP dose compendium. After 60 days with no intervention and highly conservative conditions, the dose consequence to individuals directly on the property downwind of the building for …
-
Dose efetiva comprometida devida aos radionuclídeos 40K, 226Ra, 228Ra e 228Th contidos nos alimentos da dieta da população do Estado do Rio de Janeiro
Committed effective dose due to the consumption of natural radionuclides 40K, 226Ra, 228Ra and 228Th was estimated from the high-resolution gamma spectrometry, food consumption data for the inhabitants of Rio de Janeiro state and dose coefficients published by the ICRP 119. The analyzed samples …
-
Evaluation of internal contamination levels after a radiological dispersal device using portal monitors
… and 10-Year-Old Child. The biokinetics via Dose and Risk Calculation Software (DCAL) was implemented using both the inhalation and ingestion pathways to determine the radionuclide concentrations in the organs of the body which were then used to determine the count rate of the portal monitor …
-
Internal Dose Assessment Following a Postulated Accident at a Tungsten-Target Spallation Source : Modelling and Assessment of Inhaled Radionuclides
… in the form of aerosolised Gd₂O₃, on internal dose assessment. ¹⁴⁸Gd was investigated in particular because it was identified by the Swedish Radiation Safety Authority as potentially dominant contributor to the inhalation dose in the postulated accident scenario. Atmospheric dispersion …
-
Comparison of the Recent ICRP Occupational Intakes of Rradionuclides Series to Annual Limits on Intake (ALI) in the United States for Select Radionuclides
Dose coefficients (DCs) and secondary limit values (such as the annual limit on intake [ALI] and derived air concentration [DAC]) are useful and convenient quantities in radiation protection (RP) for estimation of radiological dose and the practical application of dose limits. DCs link …
-
Machine Learning Reconstruction of Intake Activity from Historical Sr-90 Inhalation Beagle and Pu-238 Injection Mice Datasets
… in the body, which in turn informs internal dose estimates to assess health risks. Biokinetic models, primarily published by the International Commission on Radiological Protection (ICRP), are standard compartment models that may be encapsulated by systems of first-order differential …
-
RISK OF CANCER AND OCULAR DISEASES FOLLOWING CT SCANS
… thesis, the potential association between low-dose IR exposure from CT scans and the development of certain ocular conditions and cancers among residents of Ontario, Canada was studied. Data on CT scans were obtained from the Ontario Health Insurance Plan (OHIP) database. We first estimated …
-
RISK-INFORMED DECISION-MAKING FOR POTENTIAL INHALATION OF PLUTONIUM-239 AND -238 DIOXIDE NANOPARTICLES: USE OF DEFAULT ASSUMPTIONS AND MATERIAL-SPECIFIC DATA FOR ASSESSING DOSE
… derives specific blood absorption parameters and dose coefficients for inhalation of PuO2 nanoparticles from historical studies in laboratory animals; assesses the impacts on the interpretation of bioassay measurements associated with the inhalation of PuO2 nanoparticles; and analyzes the options …
-
The Development and Validation of a First Generation X-Ray Scatter Computed Tomography Algorithm for the Reconstruction of Electron Density Breast Images Using Monte Carlo Simulation
… MC simulations were also used to quantify the dose per scan. The ring measures a fraction of the total single incoherent scatter which is proportional to ray integrals of (rho_e) and can be quantified even when electron binding is non negligible. The algorithm typically reconstructs accurate …
-
Prospective Estimation of Radiation Dose and Image Quality for Optimized CT Performance
… raised regarding the population-based radiation dose associated with CT examinations [7]. From 1980 to 2006, the effective dose from medical diagnostic procedures rose six-fold, with CT contributing to almost half of the total dose from medical exposure [8]. For each patient, the risk associated …
-
Radiological imaging of neonates: radiation dose and image quality
… to radiography, in view of the high organ doses involved with this modality, it is important for radiologists and operators to be able to easily estimate doses and cancer risks, and optimise protocols depending on patients size. Radiation damage is more extensive on dividing cells, thus …
-
Towards establishing a fit-for-purpose regulatory framework for radiation protection in Western Australia's mining industry: Evaluating mine worker exposures to naturally occurring radionuclides
… and mineral extraction processes, and radiation doses that exceed applicable exposure standards may eventuate. The central issue addressed by this research is “what is the potential for radiation exposures from NORs to the significantly increased workforce, and is the regulatory framework …
-
Development and Application of Simulation Tools for Virtual Imaging Trials in Computed Tomography
… scattered component of the signal with radiation dose have proven effective for simulating realistic images. Although an effective methodology for simulating images, it requires obtaining realistic scanner-specific estimates of radiation dose and projection-specific scatter in a time-efficient …