Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 219 for “"dose delivery"”

  1. Dose Delivery Parameters in Photobiomodulation Therapy

    … of the processes associated with optical delivery to both surface and sub-surface target tissues. With the innovation of dedicated PBM devices which can deliver a higher output power than previously used, as well as equipment designs built around concepts based on theory, there is an …

    de-montfort

  2. Dose delivery uncertainty in photon beam radiotherapy

    It is known that slight variations in total dose delivered to the patient in external beam photon radiotherapy can significantly alter the probability of tumour control. For this reason, ICRU has recommended a goal of $ pm$5% precision in the dose delivery to the target volume. Several …

    mcgill Repository record for Dose delivery uncertainty in photon beam radiotherapy (opens in a new tab)

  3. Optimal Control of Dose Delivery in Brachytherapy

    … is dependent on delivering a critical radiation dose to the tumour while minimising exposure to surrounding healthy tissue and organs at risk.<br/><br/>Current clinical dose calculation methods, such as the TG-43 formalism, rely on simplified assumptions that limit accuracy, particularly in …

    bath Repository record for Optimal Control of Dose Delivery in Brachytherapy (opens in a new tab)

  4. Dose Delivery Study for a Novel Compact Proton Accelerator

    … Active spot scanning to deliver highly conformal dose to the tumor has been developed. However, the availability of proton therapy to the patients is still limited, partly, due to the high costs and sizes of large proton therapy centers. Therefore, a novel compact proton single room facility based …

    heid-diss Repository record for Dose Delivery Study for a Novel Compact Proton Accelerator (opens in a new tab)

  5. Homogeneous dose delivery for very high energy electron beams

    … feasible. There is interest in using VHEE for dose delivery to deep-seated tumours, as well as inducing the FLASH effect - a phenomenon which selectively spares healthy tissues at ultra-high dose rates. Shaping of the beam to the tumour for conformal treatment is essential. The tumour may be …

    oxford Repository record for Homogeneous dose delivery for very high energy electron beams (opens in a new tab)

  6. MEDICAL DOSIMETRY AND DOSE DELIVERY FOR PHOTOBIOMODULATION AND PHOTODYNAMIC THERAPY

    MEDICAL DOSIMETRY AND DOSE DELIVERY FOR PHOTOBIOMODULATION AND PHOTODYNAMIC THERAPY Dennis Sourvanos Joseph P. Fiorellini Timothy C. Zhu The successful application of Photobiomodulation (PBM) and Photodynamic Therapy (PDT) in clinical settings is challenging due to the complex tissue boundaries and …

    penn Repository record for MEDICAL DOSIMETRY AND DOSE DELIVERY FOR PHOTOBIOMODULATION AND PHOTODYNAMIC THERAPY (opens in a new tab)

  7. Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools

    … thesis, entitled “Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools”, focuses on the exploitation of simulation tools to optimize different aspects of the multidimensional process of magnetic hyperthermia. These aspects include the …

    patras-thes Repository record for Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools (opens in a new tab)

  8. Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools

    … thesis, entitled “Optimization of thermal dose delivery in Magnetic Nanoparticle Hyperthermia, using novel simulation tools”, focuses on the exploitation of simulation tools to optimize different aspects of the multidimensional process of magnetic hyperthermia. These aspects include the …

    greece Repository record for Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools (opens in a new tab)

  9. Dose delivery and microenvironment dependent transcriptomic profiles of tumour cells exposed to ionizing radiation /

    … RT treatment is usually applied in fractioned doses of IR, where the oncological patients receive small (2 Gy) doses of IR every 24 hours 5 days a week. However, after a periodic exposure to fractioned dose IR tumor cells acquire a resistance to RT. In order to evaluate mechanisms leading to …

    vilnius Repository record for Dose delivery and microenvironment dependent transcriptomic profiles of tumour cells exposed to ionizing radiation / (opens in a new tab)

  10. Towards adaptive radiation therapy--a framework for inclusion of organ deformation in adaptive dose delivery

    … patient specific variations in planning and delivery of radiation with the ultimate goal of improving the therapeutic ratio. Deformable image registration (DIR) has the potential to include organ deformation in the adaptive dose delivery. Our goal in this dissertation is to develop methods …

    umn Repository record for Towards adaptive radiation therapy--a framework for inclusion of organ deformation in adaptive dose delivery (opens in a new tab)

  11. Experimental Verification of 4D Monte Carlo Simulations of Dose Delivery to Moving and Deforming Anatomies

    … this work was to validate a 4D Monte Carlo (MC) dose calculation tool (4DdefDOSXYZnrc/EGSnrc) by comparing dose calculations with measurements in rigid and deforming anatomies. This 4DMC approach, that is based on the voxel warping method, calculates the cumulative dose by including continuous …

    carleton Repository record for Experimental Verification of 4D Monte Carlo Simulations of Dose Delivery to Moving and Deforming Anatomies (opens in a new tab)

  12. Influential Factors and Predicting Dose Delivery Accuracy for Imaging and Radiation Oncology Core’s Phantom Program using Machine Learning

    … The goal of the phantom audit is to compare the dose delivered to the dose planned by the treatment system ensuring dose delivery accuracy. While IROC’s phantoms are better equipped to catch dose delivery errors compared to a clinic’s QA process, the end-to-end process and reporting of results is …

    uthsc Repository record for Influential Factors and Predicting Dose Delivery Accuracy for Imaging and Radiation Oncology Core’s Phantom Program using Machine Learning (opens in a new tab)

  13. Monte Carlo Modeling of a Varian 2100C 18 MV Megavoltage Photon Beam and Subsequent Dose Delivery using MCNP5

    … against experimentally measured depth dose data. The model presented in this work establishes the foundation to which further beam characteristics tuning is required in order to realistically model the beam mentioned above. It has been determined in this work that the initial electron …

    gatech Repository record for Monte Carlo Modeling of a Varian 2100C 18 MV Megavoltage Photon Beam and Subsequent Dose Delivery using MCNP5 (opens in a new tab)

  14. Intraoperative use of c-arm cone beam CT for quality assurance of low dose rate prostate brachytherapy dose delivery

    Prostate cancer is the most diagnosed cancer among men. Many patients with localized prostate cancer are treated with brachytherapy, one form of which involves permanent implantation of approximately 100 radioactive sources into and sometimes immediately around the prostate while the patient is …

    ubc Repository record for Intraoperative use of c-arm cone beam CT for quality assurance of low dose rate prostate brachytherapy dose delivery (opens in a new tab)

  15. The Role of Cobalt-60 Source in Intensity Modulated Radiation Therapy: From Modeling Finite Sources to Treatment Planning and Conformal Dose Delivery

    … via simple conformal treatment planning and dose delivery using a Co-60 unit. In this thesis, initial Co-60 tomotherapy planning investigations on simple uniform phantoms are extended to actual clinical cases based on patient CT data. The planning is based on radiation dose data from a …

    queens Repository record for The Role of Cobalt-60 Source in Intensity Modulated Radiation Therapy: From Modeling Finite Sources to Treatment Planning and Conformal Dose Delivery (opens in a new tab)

  16. Assessment of Uncertainty In Planning and Dose Delivery of Proton Therapy In An Iroc- Houston Qa Phantom Due to Variable Ct Technique and Proton Energy

    … and proton energy will alter the delivered dose distributions of typical proton treatments by reducing the percent of passing pixels by 10% using a gamma analysis criteria of ±3%/5mm as measured using a heterogeneous proton QA phantom. A CT phantom used by IROC-H during therapy site visits …

    uthsc Repository record for Assessment of Uncertainty In Planning and Dose Delivery of Proton Therapy In An Iroc- Houston Qa Phantom Due to Variable Ct Technique and Proton Energy (opens in a new tab)

  17. Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom

    … Volume (PTV) received 100% of the prescribed dose while ensuring that normal tissue constraints were followed as well. Calculated doses were exported from the Eclipse TPS and compared with the experimental data as measured using thermoluminescence detectors (TLD) and radiochromic films that …

    uthsc Repository record for Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom (opens in a new tab)

Page 1 of 11