Results 1 to 20 of 46 for “"dose difference"”
-
Evaluation of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due to Imrt Treatment Plan Complexity and Improperly Matched Dosimetry Data
… is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region …
-
Intensity Modulated Bolus Electron Conformal Therapy (IM-BECT): Methods for Quality Assurance of PRIME Intensity Modulators and Evaluation of Planned IM-BECT Dose Distributions
… conformal therapy (IM-BECT) shapes homogeneous dose distributions to superficial, irregularly-shaped target volumes, avoiding nearby critical structures. This dissertation provides research useful for translating IM-BECT to the radiotherapy clinic by: (1) developing and testing a factory quality …
-
Stray Radiation Dose from X-ray and Proton Beam Radiation Therapies
… systems systematically underestimate the dose to tissues out-of-field. Attempts to predict and reduce the risks of radiogenic side effects require accurate and personalized knowledge of the out-of-field radiation dose to patients. The long-term goal of this research is to provide clinical …
-
Exploring appropriate offset values for pencil beam and Monte Carlo dose optimization in lung stereotactic body radiotherapy encompassing the effects of respiration and tumor location
Evaluation of dose optimization using the Pencil Beam (PB) and Monte Carlo (MC) algorithms may allow physicists to apply dosimetric offsets to account for inaccuracies of the PB algorithm for lung cancer treatment with Stereotactic Body Radiotherapy (SBRT). 20 cases of Non-Small Cell Lung Cancer …
-
CLINICAL VALIDATION OF DELIVERY ANALYSIS SOFTWARE FOR PATIENT-SPECIFIC QUALITY ASSURANCE OF RADIXACT (TOMOTHERAPY) TREATMENT
… (DA) software. The %GP was calculated using a 3% dose difference (DD), a 2 mm distance-to-agreement (DTA), and a 10% threshold. A passing criterion of ≥95% was applied for PSQA evaluation. The %GP was analyzed for all sites. The %GP (2D) on the ArcCheck phantom mean γ passing rate with variability …
-
Radiotherapy X-ray dose distribution beneath retracted patient compensators
Computer designed missing tissue and dose compensators have been produced and dosimetrically tested under a linear accelerator 6MV X-ray beam. Missing tissues compensators were developed to correct for patient external contour change only. Target dose compensators were developed to achieve a …
-
Electron Monte Carlo Dose Calculation Model Dependency on Optional Applicator Specific 1D Profiles
The accuracy of a calculated dose distribution compared to the actual dose administered to a patient undergoing electron radiation treatment is dependent upon the configured electron dose calculation algorithm in the treatment planning system (TPS). Configuration of the electron Monte Carlo (eMC) …
-
Development of a Slab-based Monte Carlo Proton Dose Algorithm with a Robust Material-dependent Nuclear Halo Model
… beam algorithms (PBAs) are often utilized for dose calculation in proton therapy treatment planning because they are fast and accurate under most conditions. However, as discussed in Chapman et al (2017), the accuracy of a PBA can be limited under certain conditions because of two major …
-
Influence on different Monte-Carlo variances at the dose calculation and the impact to the commissioning
… is gradually being introduced for clinical dose computation in the quest to improve the accuracy of predicting the dose distribution to a medium from a given beam setup. Dosimetric measurement is used to verify the accuracy of the calculated dose distribution before the beam setup can be …
-
Commissioning An Anthropomorphic Spine and Lung Phantom For Remote Dose Verification of Institutions Participating In Rtog 0631
… spinal canal, esophagus, heart, and lungs. The dose to the target volume was measured with axial and sagittal planes of radiochromic film and thermoluminescent dosimeters (TLD). The dose distributions were measured with the radiochromic film calibrated to the absolute dose measured by the TLD. …
-
Evaluation of a Helical Diode Array and Planned Dose Perturbation Model for Pretreatment Verification of Volumetric Modulated Arc Therapy
… array of silicon diode detectors to measure dose in a cylindrical plane. 3DVH is an associated software that can use ArcCHECK diode measurements along with treatment planning system (TPS) data to guide a full 3D dose reconstruction. The ArcCHECK phantom, along with 3DVH software was evaluated …
-
Cone Beam Optical Computed Tomography-Based Gel Dosimetry
The complex dose distributions delivered by modern, conformal radiation therapy techniques present a considerable challenge in dose verification. Traditional measurement tools are difficult and laborious to use, since complete verification requires that the doses be determined in three dimensions …
-
Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device
… tools used in radiotherapy to monitor the dose delivered to the patient. The digital image format makes electronic portal imaging devices (EPIDs) good candidates for in vivo dosimetry. Currently there is no commercial transit dosimetry module, which could facilitate routine in vivo …
-
A Complete Dosimetric Model of the Gamma Knife Perfexion Using Penelope Monte Carlo Codes
… damage to the target structure while minimizing dose to adjacent healthy tissue. Tungsten collimators are organized into eight sectors of 24 sources each; each sector can be set to one of three collimation sizes. The collimators can produce nominal spheres of dose 16 mm, 8 mm, or 4 mm in diameter …
-
Mri-only treatment planning for anal and rectal cancer radiotherapy (MANTA-RAY)
… in terms of dosimetric calculation accuracy. Differences in CBCT patient position registration accuracy were assessed when using synthetic-CT and MRI as the reference images. The patient experience of the MRI simulation was assessed. A planning study quantified the differences between MRI- and …
-
4D-VMAT dose calculation using treatment-specific respiratory motions
… modulated arc therapy (VMAT) could contribute to differences between planned and delivered radiation dose distributions. The purpose of this work was to develop and experimentally validate a method to calculate the VMAT dose distribution in 4-dimensions (4D-VMAT dose calculation), accounting for …
-
Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom
Validation of treatment plan quality and dose calculation accuracy is essential for new radiotherapy techniques, including volumetric modulated arc therapy (VMAT). VMAT delivers intensity modulated radiotherapy treatments while simultaneously rotating the gantry, adding an additional level of …
-
Development and Clinical Application of a New Two-Dimensional in vivo Dosimetry by Electronic Portal Imaging
… in radiotherapy refers to direct measurement of dose deposited in the patient during treatment. IVD can be of great use in early detection of harmful errors, for assessment of patient setup and anatomy changes, and to guide adaptive radiotherapy. Routine IVD is hindered by the costs and …
-
Patient-specific quality assurance for IMRT
… the threshold parameters were set to a 3% dose difference and a 3-mm distance-to-agreement. Analysis of the gamma pass/fail plots for the RANDO phantom study showed the lung cases had 27.2% of the pixels exceeding gamma, while the prostate patients had 14.7%. For the prostate test cases, …
-
Monte Carlo modelling of peripheral dose and risk of secondary malignancy in flattening-filter-free and 10 MV photon beams for paediatric radiotherapy
… efficacy of RT treatments. To properly assess dose to the entire body in patients, a Monte Carlo and measurements based model was developed. This model was used to determine the dose delivered to a cohort of paediatric patients by three different photon radiotherapy treatment modes: 6MV …