Measurement of absorbed dose to water for medium energy X-rays
The aim of this thesis is to determine the factors. required to convert the air kerma measured using an ionization chamber to absorbed dose to water when irradiated with medium energy X-rays. This principally involved the determination of the ratio of the mass energy absorption coefficients of …
-
An Absorbed Dose to Water Primary Standard for Ir-192 Brachytherapy
The goal of this work was to develop an absorbed dose to water primary standard for Ir-192 brachytherapy by using a Fricke dosimeter. The radiation chemical yield (G-value) of the Ferric ions in the Fricke solution was measured at Co-60 and 250 kVp X-ray, yielding 1.610 ± 0.010 μmol J-1 and 1.602 ± …
-
Absorbed dose to water measurements in the SOBP of a clinical carbon-ion beam using water calorimetry
Up til now, the dosimetry in terms of absorbed dose to water in carbon-ion beams has not reached the same level of accuracy as in high-energy photon beams. This is strongly influenced by the standard uncertainty of the beam quality correction factor kQ. Due to a lack of experimental data, kQ is …
-
Monte Carlo conversion for the Australian primary standard of absorbed dose to water in high energy photon beams
… entails the delivery of large radiation doses to malignant tissues in the human body. These doses must be accurate in order to balance tumour control and damage to healthy tissues. The first step in accurate dosimetry is the calibration of radiation dosemeters by the national primary …
-
Determination of absorbed dose to water in a clinical carbon ion beam by means of fluorescent nuclear track detectors, ionization chambers, and water calorimetry
… the same level of accuracy as of high-energy photons. This is mainly caused by the threefold higher uncertainty of the kQ,Q0 -factor of ionization chambers, which is derived by calculations due to a lack of experimental data. The current thesis comprises two major aims with respect to the …
-
The Clinical Effect of Changing from a Dose to Water to a Dose to Medium-Based Methodology to Calculate Monitor Units for Electron Beams
… Elekta’s Monaco® electron Monte Carlo (eMC) dose calculation algorithm for electron beams. The new algorithm resulted in a change in clinical practice whereby monitor units (MU) delivered to patients would be calculated in terms of dose to medium (𝐷𝑚), rather than using measured, dose to …
-
A water calorimeter for high energy X-rays and electrons
… standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has …
-
A Novel Metrology Standard for Synchrotron Produced Monochromatic X-ray Beams
… have unique properties that are of interest to radiotherapy investigations and the characterization of radiation detectors. To facilitate the use of synchrotron-produced photons in such investigations, this project aims to determine the absorbed dose to water at depth for synchrotron-produced …
-
A PROPOSED METHODOLOGY TO ASSESS HDR [superscript]192Ir RADIAL DOSE WITH FRICKE DOSIMETRY
The radial absorbed dose to water, D(r,theta), a quantity not yet directly measured with primary standards, was assessed with the Fricke solution which has been considered as an absolute aqueous solution to perform dosimetry. To determine D(r=2 cm,theta=90°), a hollow quasi-water Fricke ring device …
-
Water-equivalence of phantom materials in proton and carbon-ion dosimetry
… in light-ion therapy in recent decades has led to a need for accurate dosimetry. At present, a calibration service based on a primary-standard calorimeter for the direct determination of absorbed dose to water for light-ion beams does not exist. Furthermore, the water-equivalent plastics …
-
Characterizing ionization chamber dosimetry in inverse planned IMRT fields
It is standard practice in radiation therapy to have two independent calculations for the number of monitor units used in patient treatment plans. The relationship between monitor units and absorbed dose to water is sophisticated for MLC-based IMRT. Verification measurements of absorbed dose to …
-
Impacte clínic del càlcul de la dosi absorbida en radioteràpia externa mitjançant un nou algorisme basat en la solució de l'equació de Boltzmann
The algorithm for calculating absorbed dose in external radiotherapy Acuros XB (AXB), based on the solution of the Boltzmann equation, has shown to achieve a higher level of accuracy than the preceding convolution/superposition algorithm AAA, especially in volumetric-modulated arc therapy (VMAT) in …
-
Investigation of the energy response of EBT-2 GAFCHROMIC™ film model
The aim of this project is to quantify the energy response of the existing EBT-2 model GAFCHROMICTM film and investigate for the eventual possible chemical compositions with improved energy response. In this work, the overall energy dependence of the EBT-2 model GAFCHROMICTM film is quantized …
-
Measurements and Monte Carlo simulations for reference dosimetry of external radiation therapy beams
… investigation of reference dosimetry of photon and electron beams is presented using measurements and Monte Carlo simulations, with specific focus on the determination of accurate beam quality conversion factors, kQ, which are needed to convert the reading of an ionization chamber calibrated …
-
Implementation of TG-351 Reference Dosimetry for a 6 MV Photon Beam in an MR-Guided Radiotherapy System
… resonance imaging (MRI) and radiation therapy to enable the visualization of anatomy in real time during treatment. The presence of a magnetic field in MRgRT affects charged particle radiation and detector responses, necessitating changes to traditional reference dosimetry procedures. The …
-
Calculated perturbation factors for the NACP-02 plane-parallel ionization chamber irradiated in water by megavoltage electron beams
Measurements of absorbed dose to water in megavoltage electron beams are carried out with cylindrical or plane-parallel ionization chambers. The perturbation factor associated with plane-parallel ionization chambers that have sufficiently large guard rings is assumed to be unity. The NACP-02 …
-
Development of a Hybrid Alanine-calorimetry Absorbed-dose Standard for Linac Electron Beams
The NRC primary standard water calorimeter is well-established for measuring dose to water in cobalt-60, linac photon beams and high-energy linac electron beams. However, for lower-energy electron beams, given the short range of electrons and the physical dimensions of the calorimeter, it is …
-
Integration of VMC++ into a Commercial Treatment Planning System
Recently, there has been interest to integrate VMC++ into the commercial treatment planning system at VCU as another Monte Carlo code option, since it has been shown to increase efficiency dramatically without introducing a significant amount of systematic error. Also, independent validation of …