Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 38 for “"dosimetry system"”.

  1. A Portal imager-based patient dosimetry system

    … in integrated mode. In this novel VMAT in vivo dosimetry technique, the portal image signal is back-projected through a rotationally averaged model of the patient to calculate a 1D in vivo dose along the axis of gantry rotation. A research ethics board clinical study was approved and …

    uvic Repository record for A Portal imager-based patient dosimetry system (opens in a new tab)

  2. A Development of a Personnel Thermoluminescent Dosimetry System

    … to develop and put into operation a radiation dosimetry system based on the phenomenon of thermoluminescence (TL) of specially prepared substances when exposed to nuclear - type radiation. The author is employed at the Omaha Public Power District (OPPD), which organized the program and at which …

    creighton Repository record for A Development of a Personnel Thermoluminescent Dosimetry System (opens in a new tab)

  3. Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator

    … order to develop Monte Carlo treatment planning system for a small animal irradiator. To accomplish this, the absolute dose calibration of the irradiator performed in accordance with the recommendations of AAPM TG-61 protocol. Both in-air and in-water calibrations were performed at a 30.5 cm …

    utswmed Repository record for Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator (opens in a new tab)

  4. Verification of intensity modulated radiation therapy beams using a tissue equivalent plastic scintillator dosimetry system

    … this method provides a truly tissue equivalent dosimetry system capable of efficiently and accurately performing field-by-field verification of IMRT plans. This work was motivated by an initial study comparing two IMRT treatment planning systems. The clinical functionality of BrainLAB’s …

    ubc Repository record for Verification of intensity modulated radiation therapy beams using a tissue equivalent plastic scintillator dosimetry system (opens in a new tab) Download PDF for Verification of intensity modulated radiation therapy beams using a tissue equivalent plastic scintillator dosimetry system (opens in a new tab)

  5. An x-ray computed tomography polymer gel dosimetry system for complex radiation therapy treatment verification

    X-ray computed tomography (CT) polymer gel dosimetry (PGD) is an attractive tool for three-dimensional (3D) radiation therapy (RT) treatment verification due to the availability of CT scanners in RT clinics. Nevertheless, wide-spread use of the technique has been hindered by low signal-to-noise CT …

    uvic Repository record for An x-ray computed tomography polymer gel dosimetry system for complex radiation therapy treatment verification (opens in a new tab)

  6. Applications of x-ray computed tomography polymer gel dosimetry

    … X-ray computed tomography (CT) polymer gel dosimetry is a unique type of dosimeter that has many advantages and the potential to address some of the challenges in the verification of dose delivery and calculation in radiation therapy. This dissertation investigates the advancement of an …

    uvic Repository record for Applications of x-ray computed tomography polymer gel dosimetry (opens in a new tab)

  7. Determination of neutron dose from criticality accidents with bioassays for blood-24Na and hair-32P

    … <p>A comprehensive study of the accident neutron dosimetry using blood and hair was performed and the results of this study are presented in this thesis. The primary objectives of this research are to establish blood-<sup>24</sup>Na and hair-<sup>32</sup>P activity measurement procedures for the …

    ut-knoxville Repository record for Determination of neutron dose from criticality accidents with bioassays for blood-24Na and hair-32P (opens in a new tab)

  8. Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification

    … challenge that utilizes a 3D NIPAM polymer gel dosimetry system with CBCT readout to verify the dosimetric and spatial accuracy of stereotactic radiosurgery (SRS) and spatially fractionated radiotherapy (SFRT) technique. Three main objectives of this work are 1) to evaluate the reproducibility …

    ubc Repository record for Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification (opens in a new tab) Download PDF for Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification (opens in a new tab)

  9. Beryllium oxide (BeO) ceramic fibre-coupled luminescence dosimetry

    … as the probe for a fibre-coupled luminescence dosimetry system is demonstrated. In order to maximise the sensitivity of the fibre-coupled luminescence dosimetry system, the light collection from the probe material into the optical fibre was simulated. Since BeO ceramics are self optically …

    adelaide Repository record for Beryllium oxide (BeO) ceramic fibre-coupled luminescence dosimetry (opens in a new tab)

  10. Development of Radiochromic Film for Spatially Quantitative Dosimetric Analysis of Indirect Ionizing Radiation Fields

    … for spatially distributed, two-dimensional (2D), dosimetry is laborious, time consuming, limited in spatial resolution, susceptible to positioning errors, and the currently accepted approach to measuring dose distribution in 2D. This work seeks to expand the current limits of indirectly ionizing …

    duke Repository record for Development of Radiochromic Film for Spatially Quantitative Dosimetric Analysis of Indirect Ionizing Radiation Fields (opens in a new tab)

  11. Development of magnesium tetraborate as a material for thermoluminescence dosimetry

    … for a laser-heated thermoluminescence (TL) dosimetry system which is under development. Near tissue-equivalent radiation absorption properties and reported sensitivity to low radiation doses offer advantages over commonly employed LiF phosphors. Sintered wafers suitable for routine …

    vt Repository record for Development of magnesium tetraborate as a material for thermoluminescence dosimetry (opens in a new tab)

  12. Design and laboratory validation of an in-ear noise dosimetry device

    … to implement a precise and reliable in-ear noise dosimetry system based on low computational algorithms that can be used in a wide variety of environments and work conditions. The adopted methodology focuses on the implementation and validation of a real-time measurement system. The proposed …

    ets-quebec Download PDF for Design and laboratory validation of an in-ear noise dosimetry device (opens in a new tab)

  13. A Real-Time Electronic Sound Analysis System with Graphical User Interface

    … problem common to musical environments. Current dosimetry technology is primarily designed for industrial environments and not suited for musical settings. At present, there are no government regulations that apply to the educational music environment as it relates to monitoring and prevention of …

    unt Repository record for A Real-Time Electronic Sound Analysis System with Graphical User Interface (opens in a new tab)

  14. SEED LOCALIZATION IN IMAGE-GUIDED PROSTATE BRACHYTHERAPY INTRAOPERATIVE DOSIMETRY SYSTEMS

    … it spreads the stages of planning, implant, and dosimetry over several weeks. Although brachytherapy is now moving towards intraoperative treatment planning (ITP) which integrates all three stages into a single day in the operating room,the American Brachytherapy Society states, “the major …

    jhu Repository record for SEED LOCALIZATION IN IMAGE-GUIDED PROSTATE BRACHYTHERAPY INTRAOPERATIVE DOSIMETRY SYSTEMS (opens in a new tab)

  15. RADPOS System as a Dose and Position Quality Assurance Tool for 4D Radiotherapy with CyberKnife

    The CyberKnife system uses Synchrony Motion Tracking to compensate for respiratory motion. This complex radiotherapy system needs independent performance verification to assure safe treatments. In this work, the RADPOS 4D dosimetry system is used to verify CyberKnife's motion tracking and delivered …

    carleton Repository record for RADPOS System as a Dose and Position Quality Assurance Tool for 4D Radiotherapy with CyberKnife (opens in a new tab)

  16. Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων

    … 3D optical computed tomography (OCT) imaging system. EBT3 films were calibrated in air for all beam qualities of a clinical unit (40-220 kVp). These data along with Monte Carlo (MC) simulations facilitated the estimation of both components of EBT3 film energy dependence in air due to variance …

    greece Repository record for Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων (opens in a new tab)

  17. An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions

    … radiation dose distributions. Treatment planning system (TPS) calculated doses are evaluated by clinicians to ensure suitable dose coverage of targeted tumours and the avoidance of excessive doses to normal tissues. The accuracy of the TPS must be validated by measurement to ensure correct patient …

    adelaide Repository record for An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions (opens in a new tab)

  18. Measurement of proton beam dose profiles using a sensitive scintillation screen observed with a CCD camera

    … a CCD camera. The main advantage of this sort of dosimetry system is its ability to do near real-time observation and analysis of the proton beam; the system offers a practical and timesaving method of quality control. Conventional proton dosimetry methods, which consist of a miniature detector …

    ubc Repository record for Measurement of proton beam dose profiles using a sensitive scintillation screen observed with a CCD camera (opens in a new tab) Download PDF for Measurement of proton beam dose profiles using a sensitive scintillation screen observed with a CCD camera (opens in a new tab)

Page 1 of 2