The development of a double focusing magnetic spectrometer
… spectrometer using its fringing field to achieve double focusing has been developed and made ready for experimental work. Its power supply delivers continuously variable currents from 0-100 amperes. The current is stable to one part in ten thousand, being regulated by a transistor amplifier which …
-
The Michigan State University iron-free double focusing beta-ray spectrometer
Thesis (Ph. D.)--Michigan State University. Department of Physics and Astronomy, 1964
-
A Double-Focusing Magnetic Spectrometer, Radiations From Silver-106, and Other Activities
Made available in DSpace on 2015-05-12T17:11:44Z (GMT). No. of bitstreams: 2 license.txt: 4848 bytes, checksum: 96035ab3f5e1c23cc7138a224ce498bd (MD5) 0005220.PDF: 5633459 bytes, checksum: 904cd1abbd1289c21c48a94fbb59f3e0 (MD5) Previous issue date: 1953
-
Atomic Masses and Neutron Separation Energies for Some Isotopes of Cadmium
<p> The large double focusing mass spectrometer operating at its theoretical resolving power of more than 100,000 at the base of the peaks has been used to measure five mass spectral doublets. The resulting single and double neutron separation energies for some cadmium nuclides are much more …
-
The design and construction of a magnetic analyzer for a two million volt electrostatic accelerator
… The magnet is the circumferential yoke, double-focusing type. Tests show its field to be uniform within one percent along its 16-inch radius, its magnetization curve to agree with the design requirements, and its cooling system to be more than adequate. A motor-generator set and a motor …
-
A search for the direct radiative capture rection D(d,[gamma])He⁴
… has been developed. It involves the use of a double focusing magnetic spectrometer in conjunction with a solid state counter mounted in the focal plane of the spectrometer, the counter determining both the energy and dE/dx of the incident particles from the reaction. The design and …
-
The Nature and Origin of Mass Spectral Peaks
… Nier, Herzog and Mattauch for the development of double-focusing instruments. Other types of instruments such as the dynamic instruments, have also been mentioned. Methods of ionisation and systems of sample introduction were described, as were the uses of mass spectrometry in analytical …
-
A multichannel electron detection system for use in a stabilized magnetic spectrometer
… is an inhomogeneous field such as exists in a double focusing spectrometer magnet. The fluxmeter measures and regulates field strength to an accuracy of one part in 1000 or one gauss, whichever is greater.
-
Coded Aperture Magnetic Sector Mass Spectrometry
… compatibility with a higher mass resolution double focusing Mattauch-Herzog mass spectrograph is demonstrated experimentally and with high fidelity particle tracing simulations. A novel electric sector lens system was designed to stigmate high order coded aperture patterned beam which shows …
-
Transverse magnetic focusing with strong spin-orbit interactions
Transverse magnetic focusing (TMF) is an experimental technique where a charge carrier is focused by a weak transverse magnetic field from a source to a detector. A little over a century ago, a TMF device consisting of a vacuum tube and a cathode was use to determine the charge-mass ratio of the …
-
Design and optimisation of new beamlines for iThemba laboratory for accelerator based sciences (iThemba LABS)
… short new beamline section has been designed. A double focusing 90° bending magnet, for separation of the proton beam from unwanted molecular hydrogen ions has to be inserted between the source and the existing beamlines. Because of space limitations the bending magnet will also be used to focus …
-
Design and optimisation of new beamlines for iThemba laboratory for accelerator based sciences (iThemba LABS0
… short new beamline section has been designed. A double focusing 90° bending magnet, for separation of the proton beam from unwanted molecular hydrogen ions has to be inserted between the source and the existing beamlines. Because of space limitations the bending magnet will also be used to focus …
-
An efficient ionizer for an atomic beam of helium and a source of doubly charged helium ions.
… a radio frequency ion source followed by a double focusing magnet. The magnet has plane parallel pole pieces with a fringing field that produces focusing in a vertical plane. The unit is designed so that at 2.5 kilovolts extraction voltage a magnetic field of 3060 gauss is required to bend …
-
Direct Observation of Laser Filamentation in High-Order Harmonic Generation
… fs, 4 mJ, laser pulses were observed to undergo double focusing within the gas cell, with about 4 cm separating the two foci. The region with best harmonic emission occurs midway between the two foci. The radial profile of the laser focus, 150-200 microns in diameter, evolves from a Gaussian-like …
-
The Use of Capacitive Transimpedance Amplifier Array Detectors for Mass Spectrometry
… of simultaneous detection on Mattauch-Herzog double focusing mass spectrometers, but the non-linear mass dispersion of these instruments means that the resolution is not constant across the array. A different type of dispersive instrument, the linear cycloid, has a linear mass dispersion, …
-
Εκτίμηση της έκθεσης σε PCBs και DDDs (πολυχλωριωμένα διφαινύλια και οργανοχλωριωμένα φυτοφάρμακα) σε δείγματα πληθυσμού Μακεδονίας, Αττικής, Πελοποννήσου και Κρήτης με φασματομετρία μάζης (MS) και ανιχνευτή δέσμευσης ηλεκτρονίων (ECD)
… spectrometry (GC–MS) and gas chromatography–double focusing high resolution mass spectrometry (GC–DFHRMS) using solid–liquid extraction and headspace solid phase microextraction (HSSPME) technique. Polychlorinated biphenyls (PCBs) levels were assessed in human hair samples, originating from …
-
Quantitative X-ray photoelectron spectroscopy and applications to air pollution
… to test the model were obtained on a 180° double-focusing spherical-sector electrostatic spectrometer. The relative intensities for nine pure compounds examined in the gaseous state by Mg K radiation were determined in order to assess the value of the cross-sections. Approximately 15 pure …
-
Design of Apparatus for a Sterile Neutrino Search Using 131-Cs: the HUNTER Experiment
… to form an electrostatic lens, with time focusing and spatial focusing to achieve a high momentum resolution for ions despite the extended source presented by the magneto-optical trap. The optimization algorithm presented in this dissertation achieves a momentum precision of ∼0.12% …