  1. TWO-PHOTON DOUBLE RESONANCE SPECTROSCOPY IN IODINEMOLECULES

    … and two-photon X(v''= 0) ¿ B(v'= 32) ¿ E(v = 3).Spectroscopy of the iodine molecules using medium and high resolutionspectrometers. We have also showed the results of our calculations on Morsepotential curves, Franck-Condon factors, Einstein A coefficients, the distribution ofrotational levels …

    ohiolink Repository record for TWO-PHOTON DOUBLE RESONANCE SPECTROSCOPY IN IODINEMOLECULES (opens in a new tab)

  2. Electron paramagnetic resonance and electron nuclear double resonance spectroscopy at 275 GHz

    A spectrometer for Electron Paramagnetic Resonance (EPR), operating at the very high microwave frequency of 275 GHz in both continuous wave (cw) and pulsed mode, is described and its capabilities are illustrated. A superconducting magnet provides the magnetic field up to 12 Tesla and experiments …

    leiden Repository record for Electron paramagnetic resonance and electron nuclear double resonance spectroscopy at 275 GHz (opens in a new tab)

  3. Disentangling the Formation of PAHs in Extreme Environments by IR/UV Double Resonance Spectroscopy

    … well as combustion related models favour small resonance stabilized radicals (RSR) as major contributors to PAHs in sequential reactions. Therefore, we generated two RSR under well-defined conditions to investigate their contribution to PAH formation in a pyrolysis microreactor. The various …

    wurz-thes Repository record for Disentangling the Formation of PAHs in Extreme Environments by IR/UV Double Resonance Spectroscopy (opens in a new tab)

  4. Measurement of Transient Coherent Effects in IR/THz Double Resonance Spectroscopy in the Low-Pressure Regime

    … spectral fingerprint as pressure increases. A double-resonance (DR) infrared (IR)/Terahertz (THz) ro-vibrational spectroscopy solution is proposed. The ability to discriminate between molecules or specific isotopic isomers of the same molecule using this double-resonance spectroscopy (DRS) …

    ucf Repository record for Measurement of Transient Coherent Effects in IR/THz Double Resonance Spectroscopy in the Low-Pressure Regime (opens in a new tab)

  5. IR/UV Double-Resonance Spectroscopy of Reactive Hydrocarbon Species and their Reaction Products in Cold Molecular Jets

    … carrier gas. As methodology, IR/UV ion dip spectroscopy has been utilized, which delivers massselected gas-phase IR spectra of all ionizable species detectable in the molecular beam. These, with the help of DFT calculations, allow for determination of the fingerprint IR spectra, …

    wurz-thes Repository record for IR/UV Double-Resonance Spectroscopy of Reactive Hydrocarbon Species and their Reaction Products in Cold Molecular Jets (opens in a new tab)

  6. HIGH RESOLUTION INFRARED - INFRARED DOUBLE RESONANCE SPECTROSCOPY STUDY OF THE TRIPLET GROUND STATE OF THE RUBIDIUM DIMER

    … on the high resolution infrared-infrared (IRIR) double resonance spectroscopy study of the Rubidium dimer triplet ground state a3Σu+. We have observed fluorescence to this state for J=30, 50 and 70 rotational quantum numbers. We have used a perturbed pair of rovibrational levels in the A1Σu+ ~ …

    temple Repository record for HIGH RESOLUTION INFRARED - INFRARED DOUBLE RESONANCE SPECTROSCOPY STUDY OF THE TRIPLET GROUND STATE OF THE RUBIDIUM DIMER (opens in a new tab)

  7. Experimental Studies of Highly Charged Ions in a Penning Trap for the Measurement of Electron Magnetic Moments by Double-Resonance Spectroscopy

    … of a Penning trap. From this laser-microwave double-resonance technique the g factor can be determined on a ppb level of accuracy in our apparatus. We have built a novel ’half-open’ Penning trap with high fluorescence-detection efficiency and an integrated electron-beam ion source for …

    heid-diss Repository record for Experimental Studies of Highly Charged Ions in a Penning Trap for the Measurement of Electron Magnetic Moments by Double-Resonance Spectroscopy (opens in a new tab)

  8. Precision spectroscopy of ions stored in the ARTEMIS Penning trap and the CRYRING storage ring

    … at the 10-9 level by performing laser-microwave double-resonance spectroscopy. To receive such ions from GSI, ARTEMIS must be connected to the deceleration facility HITRAP. This thesis deals with the design, installation and first tests of the so-called vertical beamline which is responsible for …

    heid-diss Repository record for Precision spectroscopy of ions stored in the ARTEMIS Penning trap and the CRYRING storage ring (opens in a new tab)

  9. The Radiative Lifetime Measurement on 61Σ+g (v = 9, 10, 11, J = 31) Excited States of Molecular Sodium Using Time Resolved High Resolution Doubled Resonance Spectroscopy

    … molecules in the gas phase is done using a double resonance spectroscopy. The emitted fluorescence during decay for the 61Σ+g → A1Σ+u transition is observed, and time-correlated photon counting technique is employed to measure the lifetime of the excited state at various argon pressures. The …

    ohiolink Repository record for The Radiative Lifetime Measurement on 61Σ+g (v = 9, 10, 11, J = 31) Excited States of Molecular Sodium Using Time Resolved High Resolution Doubled Resonance Spectroscopy (opens in a new tab)

  10. Molecular Spectroscopy Experiment to Measure Temperature-Dependent Radiative Lifetime of the SODIUM MOLECULE 6sΣ𝑔(𝑣 = 9, 𝐽 = 31) State

    … state. Using pulsed lasers, the time-resolved double-resonance spectroscopy method was employed for the excitation scheme. The molecular fluorescence was observed from the 6sΣ𝑔(𝑣=9,𝐽=31) to the 𝐴sΣ𝑢(𝑣′,𝐽′) electronic state and the lifetime measurement was done using a time-correlated photon …

    ohiolink Repository record for Molecular Spectroscopy Experiment to Measure Temperature-Dependent Radiative Lifetime of the SODIUM MOLECULE 6sΣ𝑔(𝑣 = 9, 𝐽 = 31) State (opens in a new tab)

  11. Non-Destructive Detection and Resistive Cooling of Highly-Charged-Ion Ensembles for Precision Spectroscopy in the ARTEMIS Penning Trap

    … as 40Ar13+ and 209Bi82+, using microwave-laser double resonance spectroscopy on a ppb level of accuracy. The foreseen measurement scheme involves spectroscopy of a large number of confined particles in the form of an ensemble, typically of the order of 105 ions. This thesis presents the …

    heid-diss Repository record for Non-Destructive Detection and Resistive Cooling of Highly-Charged-Ion Ensembles for Precision Spectroscopy in the ARTEMIS Penning Trap (opens in a new tab)

  12. The g-Factor of Hydrogen-Like Heavy Ions as a Test for QED

    … the g-factor is determined using laser-microwave double-resonance spectroscopy. Presently, electron trapping is possible inside the Cooler trap and the trap is being prepared to trap ions.

    heid-diss Repository record for The g-Factor of Hydrogen-Like Heavy Ions as a Test for QED (opens in a new tab)

  13. Vibrational Relaxation Pathways and Torsional Large Amplitude Motion Studies in the CH-Stretch Region of CH<sub>3</sub>OH and CH<sub>3</sub>OD

    … the key impact of low-order coupling resonances and role of torsional large amplitude motion in vibrational dynamics. These efforts include a detection of rotationally resolved infrared spectra of jet-cooled CH<sub>3</sub>OH and CH<sub>3</sub>OD in the region of CH stretch fundamentals …

    ohiolink Repository record for Vibrational Relaxation Pathways and Torsional Large Amplitude Motion Studies in the CH-Stretch Region of CH<sub>3</sub>OH and CH<sub>3</sub>OD (opens in a new tab)

  14. Studies and Cooling of Highly Charged Ion Ensembles in the ARTEMIS Trap and High-Precision Mass Measurements of 221Fr, 219Rn, 213Bi, 211Pb, 209Pb, 207Tl and 207Pb at SHIPTRAP

    … possibilities for mass spectrometry and spectroscopy of atomic ions with high precision. Two such experiments based on Penning traps are SHIPTRAP and ARTEMIS at the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt. The ARTEMIS experiment is designed to measure the magnetic moment …

    heid-diss Repository record for Studies and Cooling of Highly Charged Ion Ensembles in the ARTEMIS Trap and High-Precision Mass Measurements of 221Fr, 219Rn, 213Bi, 211Pb, 209Pb, 207Tl and 207Pb at SHIPTRAP (opens in a new tab)