Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"draught risk"”.

  1. Investigation of Personal Comfort Systems: Experimental Evaluation of Desk and Wearable Fans in Shared Office Environments

    … of the primary occupant and associated localized draught risk to adjacent co-workers. Experiments were conducted in a controlled office space (25 ± 1 °C, 40 ± 5% RH) with a 23-segment adaptive thermal manikin. Results show that whole-body cooling is primarily governed by airflow intensity and …

    concordia Download PDF for Investigation of Personal Comfort Systems: Experimental Evaluation of Desk and Wearable Fans in Shared Office Environments (opens in a new tab)

  2. Enhancement of panel radiator based hydronic central heating system using flow pulsation

    … at 20±1.6oC, air velocity of below 0.15m/s and draught risk parameters of less than 15%. The numerical results agreed well with experimental results with maximum deviation of radiator temperature output of ±4.1%, indoor temperature ±2.83% and energy saving of ±1.7%. The energy saved due to the …

    birmingham Download PDF for Enhancement of panel radiator based hydronic central heating system using flow pulsation (opens in a new tab)

  3. A critical appraisal of the use of displacement ventilation in commercial buildings

    … supplementary cooling devices have presented a risk of negating the air quality benefits and the nature of these risks are exposed using smoke visualisation techniques. It is concluded that it is inaccurate to describe the use of displacement ventilation system as such, when used in combination …

    southwales Repository record for A critical appraisal of the use of displacement ventilation in commercial buildings (opens in a new tab) Download PDF for A critical appraisal of the use of displacement ventilation in commercial buildings (opens in a new tab)

  4. Indoor climate with personalized and centralized room systems

    … micro-environment near the workstation with less draught risk. With the micro-environment system, the local low velocity unit and personalized ventilation air terminal device can supply the outdoor air directly to the breathing zone. The radiant cooling panels were installed over the workstation …

    aalto Repository record for Indoor climate with personalized and centralized room systems (opens in a new tab)

  5. Assessment on the performance of the enhanced displacement ventilation system in the tropics

    … to the conventional DV system. However, the draught risk and energy consumption issues have become a problem with the 4-fan system. Hence, a 2-fan enhanced DV system is developed in this study to overcome these problems. Experiments were carried out in a mock-up office at the National …

    nus Repository record for Assessment on the performance of the enhanced displacement ventilation system in the tropics (opens in a new tab) Download file for Assessment on the performance of the enhanced displacement ventilation system in the tropics (opens in a new tab)

  6. Effects of Indoor Climate on Occupants’ Perception and Work Performance in Office Environment

    … and badly implemented layout in office can cause draught (Publication I). The flow pattern in the room is not stable and the position of draught risk areas can change in time and also due to changes in room heat sources (Publication I). On the other hand, insufficient air conditioning seems to …

    aalto Repository record for Effects of Indoor Climate on Occupants’ Perception and Work Performance in Office Environment (opens in a new tab)

  7. Computational fluid dynamics (CFD) applied to buildings sustainable design: natural ventilation. Case study

    … are used to evaluate indoor comfort conditions: draught risk (DR), predicted mean vote (PMV) and predicted percentage of dissatisfied people (PPD). The results show that comfort conditions can be reached more energy efficiently by means of NV use. Afterwards, it is verified how the comfortable …

    upv Repository record for Computational fluid dynamics (CFD) applied to buildings sustainable design: natural ventilation. Case study (opens in a new tab)

  8. Vytápění bytových domů

    Tématem této diplomové práce je vytápění bytových domů, kde byla zaměřena pozornost na tepelný komfort ve vytápěných místnostech. První část se tomuto tématu věnuje v teoretické rovině, kde jsou prezentovány i výsledky CFD simulací týkající se přímého srovnání otopných těles a podlahového vytápění. …

    brno-tech Repository record for Vytápění bytových domů (opens in a new tab)