Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 5 of 5 for “"dual bolus"”

  1. Quantification of cardiac magnetic resonance imaging perfusion in the clinical setting at 3T

    … parameter (DP) modelling are compared in single bolus versus dual bolus analysis. For model-based myocardial blood flow quantification, the convolution of a model with the arterial input function (i.e. contrast agent concentration-time curve extracted from the left ventricular cavity) is fitted …

    essex Repository record for Quantification of cardiac magnetic resonance imaging perfusion in the clinical setting at 3T (opens in a new tab)

  2. Quantification of cardiac magnetic resonance imaging perfusion in the clinical setting at 3T

    … parameter (DP) modelling are compared in single bolus versus dual bolus analysis. For model-based myocardial blood flow quantification, the convolution of a model with the arterial input function (i.e. contrast agent concentration-time curve extracted from the left ventricular cavity) is fitted …

    edinburgh Repository record for Quantification of cardiac magnetic resonance imaging perfusion in the clinical setting at 3T (opens in a new tab)

  3. Validation of Quantitative Myocardial Perfusion Magnetic Resonance Imaging

    … To enable accurate quantification a universal dual-bolus method was developed. The design of the heart allowed exquisite control regarding overall and regional blood-flow and imaging by identical equipment used for humans. Quantitative perfusion imaging showed a good correlation with …

    kings Repository record for Validation of Quantitative Myocardial Perfusion Magnetic Resonance Imaging (opens in a new tab)

  4. Quantitative Dynamic Contrast Enhanced Magnetic Resonance Imaging for Evaluation of the Myocardium in Ischaemic Heart Disease

    … compared were independent sampling strategies (dual-bolus and dual-sequence), previously proposed model based correction (native T1 or proton density weighted image based) and bookend T1 based correction which is proposed as a method to account for imperfect magnetisation preparation. The …

    whiterose Repository record for Quantitative Dynamic Contrast Enhanced Magnetic Resonance Imaging for Evaluation of the Myocardium in Ischaemic Heart Disease (opens in a new tab)

  5. Srovnání preklinických DCE-MRI perfusních technik

    … Simulacemi bylo prokázáno, že ideálně by druhý bolus měl být co nejvzdálenější od prvního. Simulace přerušení akvizice nevedly k jednoznačnému závěru, ale byly formulovány dva body, jejichž splnění by mělo vést k co nejlepšímu odhadu perfusních parametrů.

    brno-tech Repository record for Srovnání preklinických DCE-MRI perfusních technik (opens in a new tab)