Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 111 for “"dual-stage"”.

  1. Dual-stage Thermally Actuated Surface-Micromachined Nanopositioners

    … of freedom; some are composed of multiple stages that stack together. Both macro-scale and micro-scale nanopositioners have been fabricated. A summary of recent research in micropositioning and nanopositioning is presented to set the background for this work. This research project …

    byu Repository record for Dual-stage Thermally Actuated Surface-Micromachined Nanopositioners (opens in a new tab) Download PDF for Dual-stage Thermally Actuated Surface-Micromachined Nanopositioners (opens in a new tab)

  2. A dual-stage approach to dental image registration.

    … performance for dental image registration, a dualstage approach is proposed which is based on the hypotheses generation-verification paradigm. The registration of the dental regions of interest is the basis for hypotheses generation. The hypotheses generated by using a fast method are verified …

    wvu Repository record for A dual-stage approach to dental image registration. (opens in a new tab)

  3. A new dual-stage multicomponent thermosetting polymer system

    … use in bonding aramid honeycomb core composites. Dual-stage curing to meet the unique requirements of the honeycomb manufacturing process was achieved with a tricomponent mixture of epoxy and dicyanate monomers and a carboxylic acid anhydride hardener. In the first stage of curing the anhydride …

    washington Repository record for A new dual-stage multicomponent thermosetting polymer system (opens in a new tab)

  4. Investigation of Dual Stage Acridones as a Potent Malaria Treatment

    <p>The need for potent antimalarials to prevent the emergence of drug resistant <em>Plasmodium falciparum</em> is urgent. Discovery of novel acridone chemotypes have shown promise for a new antimalarial drug treatment. Presently, two acridone chemotypes have intrinsic antimalarial potency against …

    dominican Repository record for Investigation of Dual Stage Acridones as a Potent Malaria Treatment (opens in a new tab)

  5. DUAL STAGE ACTUATOR MODELING AND CONTROL IN A CD-ROM DRIVE

    … which seeking and tracking are facilitated by a dual stage actuator consisting of the sledge and radial actuators. The optics are kept in focus by a separate actuator whose motion is orthogonal to the direction of seek. During seek or tracking, only the position of the radial actuator is …

    nus Repository record for DUAL STAGE ACTUATOR MODELING AND CONTROL IN A CD-ROM DRIVE (opens in a new tab) Download file for DUAL STAGE ACTUATOR MODELING AND CONTROL IN A CD-ROM DRIVE (opens in a new tab)

  6. Modeling and simulation of the dual stage pressure retarded osmosis systems

    … work in the system. Several confi gurations of dual stage PRO system are presented and compared to single stage PRO. The comparison is based on three proposed target functions of power density (PD), specifi c energy (SE), and work per drawn freshwater (Wdrawn). Applied hydraulic pressures and …

    uvic Repository record for Modeling and simulation of the dual stage pressure retarded osmosis systems (opens in a new tab)

  7. Repurposing of Human Protein Kinase Inhibitors Identifies Dual Stage Active Antimalarials

    … activity in both the asexual blood stage and liver stage and likely acts through involvement of amino acid starvation. Another library comprised exclusively of type II kinase inhibitors, designed to target kinases in the inactive conformation, produced several interesting lead …

    ucf Repository record for Repurposing of Human Protein Kinase Inhibitors Identifies Dual Stage Active Antimalarials (opens in a new tab)

  8. Identification and compensation of friction for a dual stage positioning system

    … demands higher accuracy of the read/write head. Dual stage actuators as compared to conventional single actuator increases the accuracy of the read/write head in hard disk drives. A scaled up version of the dual stage actuator is considered as the test bed for this thesis. Friction is present in …

    tamu Repository record for Identification and compensation of friction for a dual stage positioning system (opens in a new tab)

  9. A novel approach to a two-stroke dual stage expansion engine concept

    … to the help cylinder where the second stage expansion occurs simultaneously along with the main cylinder. The cylinders are considered to be thermally insulated and along with the parallel expansion cylinder aims to derive a higher engine efficiency. The charged induction of air is done …

    chalmers Repository record for A novel approach to a two-stroke dual stage expansion engine concept (opens in a new tab)

  10. Investigation of Dual-Stage High Efficiency and Density Micro Inverter for Solar Application

    … in the United States. Due to the fact that two-stage architecture is commonly used for single phase MIC application. A DC-DC stage with maximum power point tracking to boost the output voltage of the Photovoltaic (PV) panel is employed in the first stage, DC-AC stage is used for use to connect …

    ucf Repository record for Investigation of Dual-Stage High Efficiency and Density Micro Inverter for Solar Application (opens in a new tab)

  11. Thermodynamics and thermal-fluid transport of a dual-stage sodium thermal electrochemical converter (Na-TEC)

    … limitations have constrained previous single-stage devices to thermal efficiencies below 20%. To mitigate these limitations, the isothermal expansion can be divided into two stages: one at the evaporator temperature and another at an intermediate temperature (650 K – 1050 K). This dual-stage …

    gatech Repository record for Thermodynamics and thermal-fluid transport of a dual-stage sodium thermal electrochemical converter (Na-TEC) (opens in a new tab)

  12. Controller Design and Analysis of Dual-stage Hard Disk Drives in the Presence of Micro-Actuator Stroke Limitation

    … track is decreasing, and the traditional single-stage actuation system is insufficient for such high-precision actuation. Hence, a secondary high-bandwidth piezoelectric (PZT) type micro-actuator is widely used to enhance HDD's precision servo tracking capability. However, the micro-actuator is …

    umn Repository record for Controller Design and Analysis of Dual-stage Hard Disk Drives in the Presence of Micro-Actuator Stroke Limitation (opens in a new tab)

  13. Controller design and implementation on a two-axis dual stage nanopositioner for local circular scanning in high speed atomic force microscopy

    … to its unique scanning pattern, a high-speed, Dual-Stage Actuator (DSA) system is a natural fit. DSAs consist of the serial combination of a (relatively) low-speed, long-range piezoelectric actuator (LRA) and a high-speed, short-range piezoelectric actuator (SRA). The SRA can be dedicated to …

    bu Repository record for Controller design and implementation on a two-axis dual stage nanopositioner for local circular scanning in high speed atomic force microscopy (opens in a new tab)

  14. Development of Ion Mirror and Detection Region Configurations for Distance-of-Flight Mass Spectrometry

    … Previously DOFMS only explored a single-stage ion mirror. In principle, a dual-stage ion mirror should better compensate for energy dispersion of the ions analyzed by the DOFMS, and thus provide greater mass resolving powers. Chapter 2 explores the first dual-stage ion mirror reported for …

    buffalo Repository record for Development of Ion Mirror and Detection Region Configurations for Distance-of-Flight Mass Spectrometry (opens in a new tab)

  15. ADVANCED SENSOR FUSION AND VIBRATION CONTROL TECHNOLOGIES FOR ULTRA-HIGH DENSITY HARD DISK DRIVES

    … fusion and vibration control technologies in dual-stage HDDs. First, two novel circuit topologies of self-sensing actuation are proposed to remove the coupling effect between actuation and self-sensing. The self-sensing capability is also extended to the entire frequency. Second, the earliest …

    nus Repository record for ADVANCED SENSOR FUSION AND VIBRATION CONTROL TECHNOLOGIES FOR ULTRA-HIGH DENSITY HARD DISK DRIVES (opens in a new tab) Download file for ADVANCED SENSOR FUSION AND VIBRATION CONTROL TECHNOLOGIES FOR ULTRA-HIGH DENSITY HARD DISK DRIVES (opens in a new tab)

  16. Robust Repetitive Control and Its Application

    … of camshaft to show their effectiveness. A dual stage actuator using an electrohydraulic actuator and a piezoelectric actuator is developed to further reduce cam profile tracking errors. The design, modeling, analysis and preliminary control design of the dual stage actuator are presented. …

    uiuc Repository record for Robust Repetitive Control and Its Application (opens in a new tab)

  17. Control of Multiple Degree of Freedom Fast Tool Stages for Noncircular Turning Process

    … A robust repetitive controller is designed for a dual stage actuator system and it demonstrates the tracking performance improvement through a dual stage actuator system. The dual stage actuator system has a piezoelectric actuator inside of the hollow piston of an electrohydraulic actuator system, …

    uiuc Repository record for Control of Multiple Degree of Freedom Fast Tool Stages for Noncircular Turning Process (opens in a new tab)

  18. Enhancement of Anaerobic Digestion of Organic Fraction of Municipal Solid Waste by Microwave Pretreatment

    … (SWA20) were further evaluated in single and dual stage semi-continuous digesters at hydraulic retention times (HRTs) of 20, 15, 12 and 9 days. Overall, MW pretreatment did not enhance the AD of the whole waste at the HRTs tested. However, the use of a dual stage reactor digesting non …

    ottawa-retro Repository record for Enhancement of Anaerobic Digestion of Organic Fraction of Municipal Solid Waste by Microwave Pretreatment (opens in a new tab)

Page 1 of 6