  1. The Derivation and Testing of Three-Dimensional Line Equations That Predict the Location of Brachytherapy Sources

    … the body and a radioactive source is allowed to dwell at specific positions to treat a tumor. In normal usage, anatomical images acquired before the treatment are used to plan dwell positions, and then the plan is executed without further verifying source locations during treatment. However, …

    ohiolink Repository record for The Derivation and Testing of Three-Dimensional Line Equations That Predict the Location of Brachytherapy Sources (opens in a new tab)

  2. Direction Modulated Brachytherapy for the Treatment of Cervical Cancer

    … of the original tandem such that the new dwell positions were at the level of the original plan. The dwell positions of the ovoids or rings remained unchanged. Results: The average relative reduction in D2cc using the thinnest DMBT tandem (model 1) were: -9.65% (∆EQD2 D2ccBladder = -3.6 …

    vcu Repository record for Direction Modulated Brachytherapy for the Treatment of Cervical Cancer (opens in a new tab)

  3. Quantitative Assessment of the Source Attenuation for the New CT-compatible Titanium Fletcher-Suit-Delclos (FSD) Gynecologic Applicator

    … to potential inaccuracies in computation of dwell times and dose distribution. The purpose of this study is to quantify the effect of 192Ir source attenuation due to titanium material used in the new CT-compatible FSD applicator during treatment delivery.For this study a detailed geometry of …

    ohiolink Repository record for Quantitative Assessment of the Source Attenuation for the New CT-compatible Titanium Fletcher-Suit-Delclos (FSD) Gynecologic Applicator (opens in a new tab)

  4. Implementation of MR image-guided adaptive brachytherapy for cervix cancer

    … (SA) - for automatically determining the dwell time configuration based on a set of specified dose-volume constraints. Application to a computer simulation model showed that SA was effective when the model structure sizes and distances are in a normal range. The effects on the optimization …

    alberta Repository record for Implementation of MR image-guided adaptive brachytherapy for cervix cancer (opens in a new tab)

  5. Automated Treatment Planning Framework for Cervical Cancer in Brachytherapy

    … guides the radioactive source to specific dwell positions for defined durations, known as dwell times, allowing for a conformal dose to the tumor while minimizing exposure to surrounding organs at risk (OAR). However, due to the inherent nature of ionizing radiation, some dose to OARs is …

    vcu Repository record for Automated Treatment Planning Framework for Cervical Cancer in Brachytherapy (opens in a new tab)

  6. The use of Machine Learning System in Brachytherapy Treatment Planning

    … of a treatment plan is to determine where (dwell position) and how long (dwell time) the radiation source should pause to expose its radiation. Each implanted catheter provides a set of possible dwell positions. Combinations of the possible dwell positions and dwell times, as well as …

    mcgill Repository record for The use of Machine Learning System in Brachytherapy Treatment Planning (opens in a new tab)

  7. Monte Carlo simulations for brachytherapy

    … radioactive source is placed at different dwell positions close to or within the tumor. The standard method for treatment planning in brachytherapy is to follow the TG43-formalism where the full patient geometry is treated as water. This approximation has limitations in the modelling of …

    chalmers Repository record for Monte Carlo simulations for brachytherapy (opens in a new tab)

  8. Evaluation of a MapCHECK2<sup>TM</sup> Diode Array for High Dose Rate Brachytherapy Quality Assurance

    … location of the measured dose profile for each dwell position provided the X and Y coordinates while the full width at half maximum (FWHM) of each peak was used to calibrate the source distance along the Z axis. Two treatment orientations were considered with the source moving along 1) the …

    ohiolink Repository record for Evaluation of a MapCHECK2<sup>TM</sup> Diode Array for High Dose Rate Brachytherapy Quality Assurance (opens in a new tab)

  9. Inter-fraction Variability of High-Risk Clinical Target Volume (HR-CTV) and Organs at Risk (OARs) in Cervical Cancer High-Dose-Rate (HDR) Brachytherapy

    … in which treatment parameters including source dwell positions and point A coordinate differed from fraction one were categorized as “Replan,” whereas fractions without changes were classified as “No Replan.” To determine statistical differences, a two-sided unpaired t-test was performed …

    umn Repository record for Inter-fraction Variability of High-Risk Clinical Target Volume (HR-CTV) and Organs at Risk (OARs) in Cervical Cancer High-Dose-Rate (HDR) Brachytherapy (opens in a new tab)

  10. Exploring the usefulness of artificial intelligence in medical physics: An end-to-end application to brachytherapy treatment planning

    … was marginally acceptable (48.1%), the total dwell time variation ranged from marginally acceptable (tandem [39.7%]) to unacceptable (ring [61.9%]), and the variation in the number of points used during the reconstruction of the applicator was unacceptable (>99%). Participants recommended …

    ohiolink Repository record for Exploring the usefulness of artificial intelligence in medical physics: An end-to-end application to brachytherapy treatment planning (opens in a new tab)

  11. Utilizing Monte Carlo Simulation for advanced dosimetry and verification in high energy photon brachytherapy with 192Ir

    … requiring a large mould with numerous source dwell positions. MC dosimetry was compared to TPS dosimetry based on the TG-43 formalism and Advanced Collapsed cone Engine (ACE) algorithms. A TG-43 overestimation was observed, with local median dose differences of about 10% for the clinical …

    freiburg-diss Repository record for Utilizing Monte Carlo Simulation for advanced dosimetry and verification in high energy photon brachytherapy with 192Ir (opens in a new tab)

  12. Characterization Of A Miniature X-Ray Source And Evaluation Of The Clinical Implications For Intraoperative Breast Radiotherapy

    … ‘effective source’ created by the multiple dwell positions for the Axxent system increases the dose to tissues ≥ 0.5-cm from the applicator surface. BIORT is performed within the operating room without the use of CT-based planning, which limits our ability to produce a DVH for the lumpectomy …

    wayne-thes Repository record for Characterization Of A Miniature X-Ray Source And Evaluation Of The Clinical Implications For Intraoperative Breast Radiotherapy (opens in a new tab)

  13. In Vivo Dosimetry in HDR Brachytherapy - pre-clinical tests of the prototype system PRO-DOSE (NU-RISE)

    … submerged in water, and irradiating at fixed positions with varying dwell times. Spatial resolution was evaluated by adjusting the alignment between the source and the PSD in increments of 0.25 mm. Temperature sensitivity was analyzed by altering the water temperature from 18°C to 40°C.For the …

    coimbro Repository record for In Vivo Dosimetry in HDR Brachytherapy - pre-clinical tests of the prototype system PRO-DOSE (NU-RISE) (opens in a new tab)

  14. Intensity modulated brachytherapy for focal prostate cancer and vaginal malignancies

    … dose distribution in brachytherapy by adjusting dwell positions and dwell times has inherent limitations in conforming the absorbed dose to the tumour's shape and sculpting it around organs at risk (OARs). This is largely due to the near-isotropic dose distribution of conventional brachytherapy …

    mcgill Repository record for Intensity modulated brachytherapy for focal prostate cancer and vaginal malignancies (opens in a new tab)