Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 108 for “"dynamic compression"”.

  1. Multidimensional dynamic compression system modeling

    … equations of a one-dimensional stage-by-stage dynamic compression system model was developed and validated. The improved method was then applied to two-dimensional post-stall models. The improvement in robustness was achieved by modeling the governing equations with upwind differencing and use …

    vt Repository record for Multidimensional dynamic compression system modeling (opens in a new tab)

  2. Dynamic Compression for Novel Haptic Interactions

    … examines one of the ubiquitous touch sensations—compression, as a novel interface and mode of interaction. Specifically, it seeks to answer questions related to how people experience compression stimulus given varying compression inputs, applications and contexts. This work first investigates …

    umn Repository record for Dynamic Compression for Novel Haptic Interactions (opens in a new tab)

  3. Lumbar Spinal Injury Under Dynamic Compression

    … consequences. Lumbar spine injuries during dynamic compression have been highly prevalent in recent American military conflicts in part due to the increased use of improvised explosive devices. The susceptibility of the lumbar spine during these scenarios can reduce functional capacity of …

    duke Repository record for Lumbar Spinal Injury Under Dynamic Compression (opens in a new tab)

  4. Extension twinning during dynamic compression of polycrystalline magnesium

    … magnesium and magnesium alloy AZ31B during dynamic compressive loading at strain rates up to 2500 s−1 at the Cornell High Energy Synchrotron Source (CHESS). The crystallographic texture of the two materials was similar, but the alloy specimens had a smaller average grain size. The texture of …

    jhu Repository record for Extension twinning during dynamic compression of polycrystalline magnesium (opens in a new tab)

  5. Examination of Maskelynite through Static Recompression and Dynamic Compression

    … is a diaplectic glass, that forms during shock compression of feldspar far below the melting point, and without fusion. Maskelynite also paramorphises precursor feldspar grains. Maskelynite is an important probe of shock-pressures at terrestrial impact sites and in many meteorites. Two …

    unlv Repository record for Examination of Maskelynite through Static Recompression and Dynamic Compression (opens in a new tab) Download PDF for Examination of Maskelynite through Static Recompression and Dynamic Compression (opens in a new tab)

  6. Damage Tolerance of Aeronautical Sandwich Structures Subjected to Dynamic Compression Loads

    … The aim of this thesis is to characterise the dynamic tolerance of aeronautical sandwich structures subjected to compression loads. Aircraft structures are designed to withstand a dynamic load typical of a survivable crash scenario which can cause materials to behave di erently compared to …

    auckland-ms Repository record for Damage Tolerance of Aeronautical Sandwich Structures Subjected to Dynamic Compression Loads (opens in a new tab)

  7. Super Rapid Crystal Growth and Quench of Monoclinic Bi-II* During Dynamic Compression

    We show that monoclinic Bi-II* forms during a dynamic compression regime with crystal growth rates from melt of ≈ 70 m/s. This extreme quench rate implies crystallization by non-diffusive processes and indicates that the liquid had a high degree of pre-ordering. Using ambient condition single …

    unlv Repository record for Super Rapid Crystal Growth and Quench of Monoclinic Bi-II* During Dynamic Compression (opens in a new tab) Download PDF for Super Rapid Crystal Growth and Quench of Monoclinic Bi-II* During Dynamic Compression (opens in a new tab)

  8. Prediction of Articular Cartilage Remodeling During Dynamic Compression with a Finite Element Model

    … performed to test the hypothesis that applying dynamic unconfined compression during culture produces het- erogeneous remodeling in newborn bovine articular cartilage explants. Het- erogeneous measures of cartilage microstructure were obtained by biochemical assays and quantified polarized light …

    calpoly Repository record for Prediction of Articular Cartilage Remodeling During Dynamic Compression with a Finite Element Model (opens in a new tab)

  9. EFFECTS OF PHYSIOLOGICAL DYNAMIC COMPRESSION LOADING ON GOLD NANOPARTICLE PERMEATION OF ARTICULAR CARTILAGE

    … consulting the literature, a custom-designed dynamic compression loading apparatus was constructed. It was controlled using an electro-mechanical linear actuator, specifically an eccentric cam, to provide various loading conditions of frequency and strain. It was determined that the device …

    clemson Repository record for EFFECTS OF PHYSIOLOGICAL DYNAMIC COMPRESSION LOADING ON GOLD NANOPARTICLE PERMEATION OF ARTICULAR CARTILAGE (opens in a new tab)

  10. NUMERICAL STUDY OF MECHANICAL BEHAVIOUR OF TUBULAR STRUCTURES UNDER STATIC AND DYNAMIC COMPRESSION

    … of components subjected to axial static and dynamic loadings. The effect of cladding a ductile material during ring compression test and energy absorption (EA) of circular tubes is evaluated. The addition of layers of a ductile material to the cross section of a ring increases its …

    mcmaster Repository record for NUMERICAL STUDY OF MECHANICAL BEHAVIOUR OF TUBULAR STRUCTURES UNDER STATIC AND DYNAMIC COMPRESSION (opens in a new tab)

  11. Modification of a One-Dimensional Dynamic Compression System Model To Calculate Stage Characteristics Internally

    <p>A one-dimensional, dynamic gas turbine engine performance analysis program, based on a modified parallel compressor theory, was enhanced with an added capability to calculate compressor stage characteristics given basic blade correlations, blade and casing geometry, and flow conditions. Total …

    ut-knoxville Repository record for Modification of a One-Dimensional Dynamic Compression System Model To Calculate Stage Characteristics Internally (opens in a new tab)

  12. Acute Effects of Peristaltic Pulse Dynamic Compression on Recovery: Kinetic, Kinematic, and Perceptual Factors

    … to determine the effects of peristaltic pulse dynamic compression administered via NormaTec recovery system provides measurable kinetic, kinematic, or perceptual benefits following a weightlifting training session. During 2 testing sessions separated by 1 week, 6 weightlifters performed dynamic …

    etsu Repository record for Acute Effects of Peristaltic Pulse Dynamic Compression on Recovery: Kinetic, Kinematic, and Perceptual Factors (opens in a new tab) Download PDF for Acute Effects of Peristaltic Pulse Dynamic Compression on Recovery: Kinetic, Kinematic, and Perceptual Factors (opens in a new tab)

  13. Poroelastic Finite Element Analysis of a Heterogeneous Articular Cartilage Explant Under Dynamic Compression in ABAQUS

    … amplitude (± 2% strain), low frequency (0.1 Hz) dynamic unconfined compression (UCC). A strong correlation has been made between the relative fluid velocity and stimulation of glycosaminoglycan synthesis. A contour plot of the model shows the relative fluid velocity during compression exceeds a …

    calpoly Repository record for Poroelastic Finite Element Analysis of a Heterogeneous Articular Cartilage Explant Under Dynamic Compression in ABAQUS (opens in a new tab)

  14. Effects of O-Ring Elastomers with Conventional and Synthesized Aviation Fuels with a Novel Elastomer Dynamic Compression System

    … methods for viewing the data in percentage of compression. Novel technical advancements of this research are: (i) design and manufacture an apparatus that records O-ring behavior with flowing fuel in one second intervals over long periods of time utilizing four highly accurate load sensors, …

    alabama Repository record for Effects of O-Ring Elastomers with Conventional and Synthesized Aviation Fuels with a Novel Elastomer Dynamic Compression System (opens in a new tab)

  15. A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model

    … performed and stabilized with either a 6-hole Dynamic Compression Plate applied in compression or a 6-hole Locking Compression Plate. Pelves were tested in cantilever bending to failure and construct stiffness, yield load, ultimate load at failure, displacement at failure, and mode of failure …

    guelph Repository record for A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model (opens in a new tab)

Page 1 of 6