Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"dysphotopsia"”.
-
Objective and subjective evaluation of dysphotopsia in normal and post-operative eyes
… theme of this thesis is the measurement of dysphotopsia, a common complaint in both the ageing population and after cataract or refractive surgery. Despite the availability of multiple objective and subjective methods to measure dysphotopsia, no single method is in common use, nor are photic …
-
Evaluation of modern intraocular lenses
… however, this results in the prevalence of dysphotopsia. A bespoke halometer was designed and validated to assess this photopic phenomenon. There is a lack of standardisation in the methods used for determining IOL orientation and thus rotation. A repeatable, objective method was developed …
-
Improving visual field tests for populations with advanced glaucoma and visual field loss in the periphery
… of the peripheral visual field and if negative dysphotopsia can be detected. This was undertaken in 30 post-cataract surgery patients, using a stimulus that moved both inwards towards the fixation point and outwards from the fixation point. The results suggested implantation of intraocular …
-
Αίτια και τεχνικές ανταλλαγής ενδοφακών
… during the Nd:Yag laser capsulotomy (2 cases), dysphotopsia (2 cases) and propionic bacterium acnes endophalmitis in one case. Finally, one posterior chamber IOL was removed from the anterior chamber. The most frequently encountered reason was calcification/opacification of hydrophilic acrylic …
-
Requirement for and optimisation of premium intraocular lenses
… design modifications were identified. Due to dysphotopsia and lack of intermediate vision through most multifocal IOL designs, the development of a trifocal IOL was shown to minimize these aspects. The current thesis, therefore, emphasises the challenges of premium IOL surgery and need for …
-
The influence of an intraocular lens design with enlarged 7.0 mm optic on the visual and optic results after a cataract surgery
… an enlarged 7.0 mm optic on the incidence of dysphotopsiae, visual acuity and contrast sensitivity after cataract surgery. Methods: A prospective monocentric randomized patient-blinded comparative clinical study was planned. Following preoperative consent and measurements, patients underwent …
-
Visual performance and adaptation to light disturbances in pseudophakic patients implanted with multifocal intraocular devices for presbyopia correction
… for size, shape and regularity of the positive dysphotopsia surrounding a source of glare (Light Distortion Analyzer - CEORLab, University of Minho, Portugal). Statistical analysis was conducted using SPSS for Windows software (version 22, SPSS, Inc.). Normality of data distribution was assessed …