Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 38 for “"earth fault."”.

  1. A DIGITAL TRANSFORMER DIFFERENTIAL AND RESTRICTED EARTH FAULT RELAY

    Many kinds of relays are used to detect faults in power transformers. Two of these relays are the restricted earth fault and transformer differential relays. The concepts of harmonic restraint and variable percentage of differential characteristic have been widely used in the conventional …

    sask Repository record for A DIGITAL TRANSFORMER DIFFERENTIAL AND RESTRICTED EARTH FAULT RELAY (opens in a new tab)

  2. Advanced Earth Fault Mitigation Using Virtual Air Gap Reactors

    … especially when dealing with single-line-to-earth (SLTE) faults, the most common type of faults in distribution networks. Traditional arc suppression coils (ASCs) used to limit SLTE fault currents are often limited by operational constraints. A novel type of ASC, the virtual air gap (VAG) …

    aalto Repository record for Advanced Earth Fault Mitigation Using Virtual Air Gap Reactors (opens in a new tab)

  3. Transient based earth fault location in 110 kV subtransmission networks

    This thesis deals with ground fault location in subtransmission networks. The main subject of the thesis is transient based ground fault location using low frequency fault generated transients. However, the thesis also considers the conventional fault location methods and reviews the various other …

    aalto Repository record for Transient based earth fault location in 110 kV subtransmission networks (opens in a new tab)

  4. A wavelet-based restricted earth-fault power transformer differential protection

    … schemes have been proposed in the last years. Faults inside the transformer protection zone may cause critical damages to this device if its protection unit does not operate. It is known the traditional phase current differential element presents low sensitivity to detect turn-to-ground faults …

    brazil-ufrn Repository record for A wavelet-based restricted earth-fault power transformer differential protection (opens in a new tab)

  5. Earth Fault Distance Computation Methods Based on Transients in Power Distribution Systems

    The most common fault type in MV distribution network is single line to earth fault. The initial transients of earth faults are important especially for unearthed and compensated neutral networks. The earth fault transient signals consist of many different frequency components, which result from …

    aalto Repository record for Earth Fault Distance Computation Methods Based on Transients in Power Distribution Systems (opens in a new tab)

  6. Magnetically Controlled Reactor - a Novel Component in Smart Grid

    … voltage in a distribution grid or compensating earth fault currents. A reactor topology was identified, modeled and validated in laboratory in which inductance could be controlled quickly, linearly and with no moving parts using an optimized virtual air gap. One promising application for this …

    aalto Repository record for Magnetically Controlled Reactor - a Novel Component in Smart Grid (opens in a new tab)

  7. Single phase earth faults in high impedance grounded networks : characteristics, indication and location

    The subject of this thesis is the single phase earth fault in medium voltage distribution networks that are high impedance grounded. Networks are normally radially operated but partially meshed. First, the basic properties of high impedance grounded networks are discussed. Following this, the …

    aalto Repository record for Single phase earth faults in high impedance grounded networks : characteristics, indication and location (opens in a new tab)

  8. One-terminal traveling wave-based protection for HVAC and HVDC transmission lines

    … through computer simulations. The proposed earth fault distance protection for HVAC transmission lines was evaluated using an actual commercial relay with time-domain-based protection functions. The results related to the proposed earth fault distance protection for HVAC transmission lines …

    brazil-ufrn Repository record for One-terminal traveling wave-based protection for HVAC and HVDC transmission lines (opens in a new tab)

  9. Distribution Automation and Self-Healing Urban Medium Voltage Networks

    … at shortening the interruption time once the fault has occurred. The research begins with the studies on customer interruption costs (CIC). Customer group and CIC variation in different urban areas are analysed. As a part of this research, also a postal survey to estimate the CIC of commercial …

    aalto Repository record for Distribution Automation and Self-Healing Urban Medium Voltage Networks (opens in a new tab)

  10. ATP modeling of internal transformer faults for relay performance testing

    … Unfortunately, they are subjected to through-faults and abnormal operating conditions which can affect not only the transformer itself but also other equipment connected to the transformer. Thus, it is essential to provide sufficient protection for transformers as well as the best possible …

    mtu Repository record for ATP modeling of internal transformer faults for relay performance testing (opens in a new tab)

  11. An Analysis on Wildfire Mitigations Employed by Utilities in California

    … evaluated are covered conductor, rapid earth fault current limiter, distribution fault analysis, and early fault detection. Each of these mitigate different failure drivers of utility lines, whether it is due to a contact from a foreign object, an equipment failure, or another driver. …

    calpoly Repository record for An Analysis on Wildfire Mitigations Employed by Utilities in California (opens in a new tab)

  12. Protection coordination study in bhutan transmission network

    … protection system is to isolate and disconnect faulted parts of the system selectively and quickly. This purpose can be achieved by proper coordination of protective devices. One of the aims of this thesis was to make a general guideline from which proper coordination of transmission system …

    chalmers Repository record for Protection coordination study in bhutan transmission network (opens in a new tab)

  13. Implementation of some digital computer algorithms for power system protection

    … and correct discrimination of resistive earth fau1ts. A significant addition to the experimental results obtained for the digital distance protection are the fault occurrences described in Appendix 4. A zone 1 fault and a resistive earth fault occurred on the monitored line and the …

    unsw Repository record for Implementation of some digital computer algorithms for power system protection (opens in a new tab)

  14. Adaptive digital distance protection for series compensated transmission lines

    … in the impedance measurement for a phase to earth fault when the spark gaps do not flash over, are discussed and new methods are proposed to compensate for these errors. The new concept of a complex residual compensation factor, as opposed to a real one, is also discussed. A new adaptive …

    city-london Download PDF for Adaptive digital distance protection for series compensated transmission lines (opens in a new tab)

  15. Intelligent Adaptive Digital Distance Relaying for High Resistance Earth Faults

    … variable window is proposed. An improved fault detection technique which is suitable for use under high resistance earth fault is also developed. Optimum performance of both operating time and reach accuracy has been obtained. The algorithm, using fast processing techniques, involves …

    city-london Download PDF for Intelligent Adaptive Digital Distance Relaying for High Resistance Earth Faults (opens in a new tab)

  16. EMTP-RV investigation of a Mho relay model for protection of 500 kV series compensated transmission lines

    … constitute a major reason for incidence of faults on the lines. The stability of the entire power system is influenced by the occurrence of faults on the high voltage transmission lines. Once a fault occurs on such a system, a delay in clearing the fault is usually not allowable; therefore, …

    concordia Download PDF for EMTP-RV investigation of a Mho relay model for protection of 500 kV series compensated transmission lines (opens in a new tab)

  17. DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY

    … by Alternative Transients Program for various fault conditions of a sample power system are applied to the relay simulation program in the first stage. Voltage and current waveforms and estimated impedance locus are formulated and plotted to examine the response of the relay software. This …

    nus Repository record for DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY (opens in a new tab) Download file for DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY (opens in a new tab)

  18. Relinės apsaugos nuo įžemėjimo atrankumo tyrimas /

    The selectivity research of link protection of grounding has been done and the grounding modes of neutrality and their influence to grounding selectivity have been analyzed. Moreover, the distribution of protection under a controlling element has been studied. The research of the equipment of link …

    vilnius Repository record for Relinės apsaugos nuo įžemėjimo atrankumo tyrimas / (opens in a new tab)

Page 1 of 2