Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 100 for “"economizer"”.

  1. HVAC Economizer Redesign

    An economizer is a HVAC (Heating, Ventilation, and Air Conditioning) appliance designed to regulate the intake and outtake of ambient air of HVAC devices, such as building air conditioners. This design project was conducted in collaboration with MicroMetl Corporation, a local sheet metal company …

    unr Repository record for HVAC Economizer Redesign (opens in a new tab)

  2. Efficiency tests of an economizer

    Made available in DSpace on 2017-11-30T22:46:07Z (GMT). No. of bitstreams: 2 5976868.pdf: 1612255 bytes, checksum: a71f598478281d2fa682ad92c40c9dd6 (MD5) license.txt: 4813 bytes, checksum: 715c4321821a960fa1a1e91d2ac7ebce (MD5) Previous issue date: 1912

    uiuc Repository record for Efficiency tests of an economizer (opens in a new tab)

  3. Airside Economizer Low Limit Effect on Energy and Thermal Comfort

    … more energy efficient systems. An airside economizer can assist with the latter. Guidance is lacking for these devices in regards to the optimal airside economizer low-limit setpoint temperature; this low-limit is the air temperature when the flow rate of outside air brought in is increased …

    ku Repository record for Airside Economizer Low Limit Effect on Energy and Thermal Comfort (opens in a new tab)

  4. Use of air side economizer for data center thermal management

    … cooling cost for the data center is an airside economizer. If outside conditions are suitable, the airside economizer introduces the outside air into the data center, making it the primary source for cooling the space and hence a source of low cost cooling. Full-scale model of a representative …

    gatech Repository record for Use of air side economizer for data center thermal management (opens in a new tab)

  5. Operating strategies for economizer control in an air conditioning system

    A typical economizer in an air conditioning system is investigated in this paper. New operating strategies of the economizer are proposed. An economizer consists of three coupled dampers--an outdoor air, a recirculation, and a discharge damper--controlled so that the amount of outdoor air may be …

    concordia Download PDF for Operating strategies for economizer control in an air conditioning system (opens in a new tab)

  6. Reduction of excess fan power due to economizer damper pressure losses

    An air conditioning system economizer, investigated in this thesis, consisted of three dampers, an outdoor air, a recirculation, and a discharge damper. The purpose of an economizer is to control the ratio of the outdoor air flow rate to the recirculation air flow rate. The dampers were opposed …

    concordia Download PDF for Reduction of excess fan power due to economizer damper pressure losses (opens in a new tab)

  7. Application of optimal control to an integral economizer U-tube steam generator

    … optimal standard of performance for an integral economizer, U-tube steam generator was established for a given performance functional, and this standard compared to the performance of integral economizer steam generators controlled by conventional analog methods. Finally, the suitability of …

    ut-knoxville Repository record for Application of optimal control to an integral economizer U-tube steam generator (opens in a new tab)

  8. A mathematical model for an integral economizer steam generator /c Don C. Arwood

    … a linearized mathematical model for an integral economizer U-tube steam generator to predict its dynamic response during normal operational transients.</p><p>The model is a linear, lumped parameter type with a nodal structure suitable for matrix solution. The standard assumptions involving a …

    ut-knoxville Repository record for A mathematical model for an integral economizer steam generator /c Don C. Arwood (opens in a new tab)

  9. Empirical validations of the DOE-2.1E building simulation software for daylighting and economizer controls

    … was to empirically validate the daylighting and economizer facets of the DOE-2.1E building simulation software with an actual building. The test facility where these validations exercises were performed was the Iowa Energy Center's Energy Resource Station (ERS). Weather information measured at …

    iastate Repository record for Empirical validations of the DOE-2.1E building simulation software for daylighting and economizer controls (opens in a new tab)

  10. Impacts of increased outdoor air flow rates on annual HVAC energy costs in office environment

    … The influence of the HVAC system using economizer, heat exchanger or both, in CAV and VAV configuration, has been studied in five European cities, which represent the five main climates in Europe. Different heating sources have been examined as well. The free cooling concept analyze has …

    chalmers Repository record for Impacts of increased outdoor air flow rates on annual HVAC energy costs in office environment (opens in a new tab)

  11. Exhaust gas economizer on auxiliary engines - A case study of potential savings that can be made by installing an exhaust gas

    … that could be made by installing an exhaust gas economizer for the auxiliary engine on board ships. The reason why many ships have not installed economizers on their auxiliary engines is because the investment has not been considered necessary before. This work is primarily a case study on the …

    chalmers Repository record for Exhaust gas economizer on auxiliary engines - A case study of potential savings that can be made by installing an exhaust gas (opens in a new tab)

  12. Control Strategy for Simultaneous Operation of Economizers and Humidifiers

    … operations. One such situation arises with economizers and humidifiers. In cold climates, an economizer offers substantial cooling energy savings by bringing in cold outside air to cool the buildings. The psychrometric chart indicates that cold air will be unconditionally dry compared to …

    tamu Repository record for Control Strategy for Simultaneous Operation of Economizers and Humidifiers (opens in a new tab) Embargoed until 2027-08-01

  13. Control Strategy for Simultaneous Operation of Economizers and Humidifiers

    … operations. One such situation arises with economizers and humidifiers. In cold climates, an economizer offers substantial cooling energy savings by bringing in cold outside air to cool the buildings. The psychrometric chart indicates that cold air will be unconditionally dry compared to …

    tamu Repository record for Control Strategy for Simultaneous Operation of Economizers and Humidifiers (opens in a new tab) Embargoed until 2027-08-01

  14. Control Strategy for Simultaneous Operation of Economizers and Humidifiers

    … operations. One such situation arises with economizers and humidifiers. In cold climates, an economizer offers substantial cooling energy savings by bringing in cold outside air to cool the buildings. The psychrometric chart indicates that cold air will be unconditionally dry compared to …

    tamu Repository record for Control Strategy for Simultaneous Operation of Economizers and Humidifiers (opens in a new tab) Embargoed until 2027-08-01

  15. Control Strategy for Simultaneous Operation of Economizers and Humidifiers

    … operations. One such situation arises with economizers and humidifiers. In cold climates, an economizer offers substantial cooling energy savings by bringing in cold outside air to cool the buildings. The psychrometric chart indicates that cold air will be unconditionally dry compared to …

    tamu Repository record for Control Strategy for Simultaneous Operation of Economizers and Humidifiers (opens in a new tab) Embargoed until 2027-08-01

  16. Control Strategy for Simultaneous Operation of Economizers and Humidifiers

    … operations. One such situation arises with economizers and humidifiers. In cold climates, an economizer offers substantial cooling energy savings by bringing in cold outside air to cool the buildings. The psychrometric chart indicates that cold air will be unconditionally dry compared to …

    tamu Repository record for Control Strategy for Simultaneous Operation of Economizers and Humidifiers (opens in a new tab) Embargoed until 2027-08-01

  17. Control Strategy for Simultaneous Operation of Economizers and Humidifiers

    … operations. One such situation arises with economizers and humidifiers. In cold climates, an economizer offers substantial cooling energy savings by bringing in cold outside air to cool the buildings. The psychrometric chart indicates that cold air will be unconditionally dry compared to …

    tamu Repository record for Control Strategy for Simultaneous Operation of Economizers and Humidifiers (opens in a new tab) Embargoed until 2027-08-01

  18. Interaction between a Supersonic Jet and Tubes in Kraft Recovery Boilers

    … sections - superheater, generating bank and economizer. The tube arrangement in these sections, particularly the tube spacing is different from each other. Moreover, tubes in an economizer are finned. A sootblower jet will interact differently with these tube arrangements, potentially …

    toronto-retro Repository record for Interaction between a Supersonic Jet and Tubes in Kraft Recovery Boilers (opens in a new tab)

Page 1 of 5