Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 24 for “"effective atomic number"”.
-
Calculation of the effective atomic number for the iodine contrast agent of the varying concentrations
… system assembled by the author. A method of the effective atomic number mapping is discussed as a viable alternative to the traditional attenuation-based tomography. The dependency of the effective atomic number of the compound on the energy of the x-ray beam is a phenomenon well recorded in the …
-
Dual energy image reconstruction and systems for application in proton therapy treatment planning
… is dependent on the electron density and effective atomic number of the material and describes the energy loss per unit length in the tissue. In current clinical practice, the SPR of patient tissues is obtained through single energy CT (SECT) scanning. The SECT scan results in a map of …
-
Feasibility of a Bone Mineral Measurement Technique Based on Coherent Scattering of Gamma Rays
… varied with object dimensions and solution effective atomic number. Simulation and experimental measurements with solutions in cylindrical polyethylene containers of varying sizes indicated that the ratio of the coherent count rate to the transmission count rate was independent of container …
-
Feasibility of a Bone Mineral Measurement Technique Based on Coherent Scattering of Gamma Rays
… varied with object dimensions and solution effective atomic number. Simulation and experimental measurements with solutions in cylindrical polyethylene containers of varying sizes indicated that the ratio of the coherent count rate to the transmission count rate was independent of container …
-
Enhanced reconstruction and material recognition in X-ray CT for security applications
… accurate estimation of properties such as effective atomic number and density of all materials. X-ray CT offers the potential for estimation of such material properties, by reconstructing the X-ray attenuation coefficients at different spatial locations, particularly when multiple sets of …
-
Radiation detection and classification of heavy oxide inorganic scintillator crystals for detection of fast neutrons
… improving efficiency, compactness, and cost effectiveness. To understand how such scintillators respond to gamma and neutron radiation, we exposed selected scintillators to different gamma and neutron sources and measured the resulting emission responses with photomultiplier tubes and …
-
Spectroscopic, Thermal, and Physical Analysis of the Raw Materials in Europium Doped Cesium Strontium Iodide Scintillator
… for this purpose should possess a high effective atomic number, high light yield, and good energy resolution. The scintillator CsSrI<sub>3</sub>: Eu [cesium strontium iodide: europium], recently developed at the Scintillation Materials Research Center, has excellent properties. Recent …
-
Planetary Ball Mill and Solution Combustion Approaches for the Production and Size Control of Nanophosphors
… properties such as its high light yield, high effective atomic number, and relatively fast decay time. Further, the gadolinium aluminum gallium garnet and other related garnet materials offer additional advantages for the production of ceramics, largely due to the ability of the garnet …
-
Compositionally Complex Rare-Earth Aluminum Garnet Ceramic Scintillators for High-Energy X-ray Radiography Applications
… light yield, low afterglow, high density and effective atomic number, be robust and easily machinable, be non-toxic, and be cost-effective. Ceramic scintillators are an attractive option due to faster, thus cheaper, fabrication via hot pressing compared to lengthy crystal growth processes. In …
-
Development of Metal Halide Perovskites for Radiation Detection
… due to their inexpensive solution growths, high effective atomic number for gamma and X-ray sensing, suitable bandgap, large resistivity, and moderate mobility-lifetime products. The MHP stoichiometry can also be tuned as needed to achieve desired physical and electronic properties. Moreover, the …
-
Four-Dimensional In Vivo Dosimetry By Dose Reconstruction Using Continuous Epid Images And Phase Sorting Method
… code has been improved by physically relevant effective atomic number modeling and employing realistic phase space data. The new model has been tested under various field sizes and phantom thickness, including homogeneous and heterogeneous media. It has been shown that the calculated EPID …
-
Exploring the Luminescence Dynamics of Lanthanide-Doped Nanoparticles: Exploiting the Temporal Dimension for Diverse Applications
… indicated that a greater material density and effective atomic number improved the efficiency of the radioluminescence process, while varying the dopant concentration was not as influential, when compared to direct ultraviolet excitation. Furthermore, the addition of Gd3+ as a sensitizer or …
-
Chalcogenide Semiconductor Single Crystal Growth for Radiation Detector Applications
… Suitable detector materials require high density/effective atomic number, an optimal band gap, high resistivity to suppress leakage current, and mechanical robustness for device fabrication. In this thesis, three chalcogenide semiconductors: Pb2P2Se6, α-AgSbS2, and Ag3SbS3 are investigated as …
-
Investigation and Characterization of New Optically Stimulated Luminescence (OSL) Dosimetric Materials
… BeO and Al2O3:C. An OSL dosimeter requires low effective atomic number (Zeff < 16), at least one type of recombination center and one type of trap, and UV~blue emission. In this dissertation, motivated by the search of new OSL dosimetric materials, a systematic investigation of alumina (Zeff = …
-
Beryllium oxide (BeO) ceramic fibre-coupled luminescence dosimetry
… is expected from BeO ceramics since it has an effective atomic number similar to water. In this thesis the feasibility of using BeO ceramic as the probe for a fibre-coupled luminescence dosimetry system is demonstrated. In order to maximise the sensitivity of the fibre-coupled luminescence …
-
Exploration of applications of photon-counting detector computed tomography (CT) using a table-top CT system
… a dual-energy CT (DECT) method for extracting effective atomic number (Zeff) and relative electron density (ρe) of tissues. We demonstrated that the method with PCD-CT was more accurate in extracting Zeff and ρe for a set of electron density phantom materials with known Zeff and ρe than the …
-
The Utility of X-Ray Dual-Energy Transmission and Scatter Technologies for Illicit Material Detection
… to characterize a material at the molecular and atomic levels. This ability is particularly important for detecting plastic explosives, where object shape information cannot be used. X-ray devices are relatively inexpensive compared to many other detection technologies. X-ray technology is …
-
Material-Specific Computed Tomography for Molecular X-Imaging in Biomedical Research
… matter interaction physics to calculate the effective atomic number () and effective electron density () from PCCT image data for material identification. As the validation of the physics model, the and were calculated under various energy conditions for many materials. The relative standard …
-
Nanoparticles as X-ray CT Imaging Contrast Agents in Saturated Porous Media
… two or more materials. The density and the effective atomic number of the material the X-rays are passing through influence attenuation. Thus, in theory, NPs comprised of elements with higher atomic numbers than geologic materials and water should attenuate X-rays more strongly and, …
-
Scalable bismuth oxyiodide devices for ionising radiation detection
… of 5500 nGyair s -1 , resulting from its low atomic number (Z=34) and low mobility-lifetime product (𝜇𝜏 = 10-7 cm2 V-1 ) which together restrict efficient X-ray attenuation at low dose rates, as well as restricting the efficient collection of charge-carriers from the detector. This thesis …
Page 1 of 2