Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 52 for “"efficiency test"”.

  1. Efficiency Test of the 'Otto' Gas Engine

    <p>In the last en years gas and petroleum motors have made such great strides that at present for small power they are superseding the steam engine, and in some localities they are even going so far as to compete with high power steam engines. In England gas engines have been constructed which …

    ut-knoxville Repository record for Efficiency Test of the 'Otto' Gas Engine (opens in a new tab)

  2. Efficiency Test of an Ingeco Kerosene Engine

    The object of this test was to increase if possible the efficiency of an Ingeco Kerosene Engine manufactured by the International Gas Engine Company of Milwaukee, the engine being rated as 12 Horse Power at 275 revolutions per minute. The increase in efficiency was to be produced by heating the …

    marquette Repository record for Efficiency Test of an Ingeco Kerosene Engine (opens in a new tab)

  3. Induction motor efficiency test methods: a comparison of standards

    In this work, fundamental aspects regarding the efficiency of induction motors are treated. Improved efficiency is the task of the hour. Environmental challenges, which include climate change, global warming and greenhouse gas emission have been fuelling the need to increase energy efficiency in …

    nwu-za Repository record for Induction motor efficiency test methods: a comparison of standards (opens in a new tab)

  4. An Efficiency Test of a Rotary Converter Capacity 7.5 K.W.

    … thesis is a study of a rotary converter and a test upon the machine. The author desires to set forth the characteristics and working possibilities of this machine in such a way that it will be known to those desiring a deep study in this machine just what to expect from it, how it operates and …

    ut-knoxville Repository record for An Efficiency Test of a Rotary Converter Capacity 7.5 K.W. (opens in a new tab)

  5. Efficiency Test of a Used Ford Motor Operated as a Stationary Engine

    <p>The object of this test was to determine the actual efficiency of a used Ford motor operating as a stationary engine. The type of engine selected was one considered representative of its class.</p>

    ut-knoxville Repository record for Efficiency Test of a Used Ford Motor Operated as a Stationary Engine (opens in a new tab)

  6. A Commercial Efficiency Test of a Power Plant Located at Marquette University

    The purpose of the test was to determine the coat of generating one kilowatt-hour of electrical energy under existing conditions of operation. The plant under test is located at the Marquette University Power House and consists of a Filer Stowell Company simple, horizontal, now-condensing Corliss …

    marquette Repository record for A Commercial Efficiency Test of a Power Plant Located at Marquette University (opens in a new tab)

  7. Effectiveness of lifetime fitness course activities at improving movement efficiency through Fusionetics movement efficiency test.

    … is a lack of evidence of improving movement efficiency (ME) that may highlight poor movement quality. The main purpose of this study was to determine how effective lifetime fitness (LF) activities at Baylor University are at improving ME. Eleven participants were recruited to perform a …

    baylor Repository record for Effectiveness of lifetime fitness course activities at improving movement efficiency through Fusionetics movement efficiency test. (opens in a new tab)

  8. Efficiency Test of Power Plant of the Rand Powder Company of Tennessee at Marlow, Tennessee

    … fan. The fan is regulated by hand.</p> <p>The test of the plant was made in colloboration with Messrs. Dickson and Williams, they making the generator tests and determining the line losses.</p> <p>A twelve hour trial of the boilers was made and three tests were made on the engine farthest from …

    ut-knoxville Repository record for Efficiency Test of Power Plant of the Rand Powder Company of Tennessee at Marlow, Tennessee (opens in a new tab)

  9. Efficiency test of the dust collector on No.6 boiler in the V.P.I. power plant

    From the tests run it was observed that load variations have a pronounced effect both on size analysis and concentration of the flyash.

    vt Repository record for Efficiency test of the dust collector on No.6 boiler in the V.P.I. power plant (opens in a new tab)

  10. Mechanical design of gear train efficiency test rig - Efficiency evaluation of geared front attachments in industrial tightening tools

    Atlas Copco desires a test rig where they can perform gear accuracy and efficiency tests with the aim of potentially enhancing the performance of their Geared Front Attachment (GFA) tool tightening solutions. The GFA extension consist of several gears positioned on a row making it possible to …

    chalmers Repository record for Mechanical design of gear train efficiency test rig - Efficiency evaluation of geared front attachments in industrial tightening tools (opens in a new tab)

  11. The Design and Development of a Capture Efficiency Test Facility By Using Tracer Gas Monitoring For Performance Testing of Kitchen Ventilation Systems

    … has been working alongside ASTM to develop a test standard for analyzing the fraction of cooking pollutants removed by kitchen range hoods. RELLIS Energy Efficiency Laboratory (REEL) was given the opportunity to design, develop, and construct a capture efficiency test facility using tracer gas …

    tamu Repository record for The Design and Development of a Capture Efficiency Test Facility By Using Tracer Gas Monitoring For Performance Testing of Kitchen Ventilation Systems (opens in a new tab)

  12. Mechanical efficiency in men and women

    … of this study was to compare the mechanical efficiency of men and women working on a bicycle ergometer. Delta efficiency, defined as the increment in workrate divided by the increment in energy expenditure, was selected as the calculation which would most accurately describe the relationship …

    ut-knoxville Repository record for Mechanical efficiency in men and women (opens in a new tab)

  13. Design verification test methods for analog input devices

    … need is met through efficient design-assurance testing. Design-assurance test methods for analog input devices were developed in a design-assurance environment from Winter 1984 through Autumn 1987. Industry test standards and analog input design techniques were researched. Test cycles were …

    ut-knoxville Repository record for Design verification test methods for analog input devices (opens in a new tab)

  14. Evaluation of upstream and downstream process parameters on electrostatic precipitator performance

    … particulate emission legislation. An ESP efficiency test was conducted at Lethabo Power Station to determine the current state of the plant and performance. The results of the test were compared with the original design base specifications to determine the relevant deficiencies which …

    nwu-za Repository record for Evaluation of upstream and downstream process parameters on electrostatic precipitator performance (opens in a new tab)

  15. Development and validation of a modular hybrid electric vehicle simulation model

    … and several transmissions. Vehicle efficiency and performance can be predicted with the Federal Test Procedure, the Highway Fuel Efficiency Test, the US06 and the Japanese 10--15 Mode driving cycles. Comparisons are made with published results for several conventional vehicles and …

    wvu Repository record for Development and validation of a modular hybrid electric vehicle simulation model (opens in a new tab)

  16. Non-Contact Optical Metrology in Reflective and Refractive Systems

    … The first project is the development of an efficiency test for a custom diffraction grating for the Aspera mission. The test was simulated and predicted a grating efficiency of 26.25 +\- 0.9978%. The hardware for the test was assembled in preparation for extreme ultraviolet vacuum tank …

    arizona-thes Repository record for Non-Contact Optical Metrology in Reflective and Refractive Systems (opens in a new tab)

Page 1 of 3