Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"ejection time"”.

  1. Kardiovaskulêre veranderinge gëinduseer deur middel van 'n binêre keusestelsel

    … is induced as reflected by the decrease in time interval measurings. Pre-ejection time, isovolumic contraction time and electromechanical systole as well as the reduction in the ratio of pre-ejection time on left ventricular ejection time and increase in left ventricular ejection time index. …

    nwu-za Repository record for Kardiovaskulêre veranderinge gëinduseer deur middel van 'n binêre keusestelsel (opens in a new tab)

  2. Analysis of left ventricular function by optimization models

    … arterial load is described by three linear time-invariant differential equations. End-diastolic volume, linear end-systolic pressure-volume relation, heart rate, and nominal ejection time are given. Under these constraints, ventricular function is described by optimality criteria that are …

    aalto Repository record for Analysis of left ventricular function by optimization models (opens in a new tab)

  3. SYNTHETIC JET MICROPUMP

    … in the produced flow rate. Changes in the ejection duty cycle, or the ejection time relative to the suction time during an actuation cycle, were found to influence the flow rate produced by the pump. A shorter ejection time produced a higher flow rate from the pump as compared to a longer …

    mcmaster Repository record for SYNTHETIC JET MICROPUMP (opens in a new tab)

  4. 'n Eksperimentele ondersoek na die hoërdinamiese funksies van die skaaphart

    … blood flow velocity in the aorta and its first time derivative (acceleration). The two noninvasive methods were the ultra low frequency acceleration ball istocardiogram and systolic time intervals. The time intervals measured, were the left ventricular ejection time, the pre-ejection period, the …

    nwu-za Repository record for 'n Eksperimentele ondersoek na die hoërdinamiese funksies van die skaaphart (opens in a new tab)

  5. The assessment of pulmonary haemodynamics with magnetic resonance imaging in pulmonary hypertension

    … and peak velocity of blood flow, acceleration time and ejection time, and calculated the ratio of acceleration time over ejection time. Finally we attempted to study the changes in these variables following straight leg raising exercise.

    edinburgh Repository record for The assessment of pulmonary haemodynamics with magnetic resonance imaging in pulmonary hypertension (opens in a new tab)

  6. Development, Validation, and Clinical Application of a Numerical Model for Pulse Wave Velocity Propagation in a Cardiovascular System with Application to Noninvasive Blood Pressure Measurements

    … inverse quadratic relationship (R^2=.99) between ejection time and PWV, with ejection time dominating the PWV shifts (12%). The second model predicts the general relationship between PWV and blood pressure with a rigorous account of nonlinearities in the fluid dynamics, blood vessel elasticity, …

    rit Repository record for Development, Validation, and Clinical Application of a Numerical Model for Pulse Wave Velocity Propagation in a Cardiovascular System with Application to Noninvasive Blood Pressure Measurements (opens in a new tab)

  7. Assessment of left ventricular size and function in horses using anatomical M-mode echocardiography

    … AMMlx und CMMsx war deutlich schlechter. Die ‚Ejection time‘ des LV und die Dauer der elektromechanischen Systole zeigten eine hohe Übereinstimmung zwischen den Methoden, die LV ‚Pre-ejection period‘ und der ‚Index of myocardial performance‘ hingegen nicht. Die intra-observer und die …

    zurich

  8. Cardiovascular responses to sustained isometric work in a hot environment

    … cardiovascular dynamics as depicted by systolic time intervals, blood pressure and heart rate during a 50% MVC and 100% MVC isometric contraction of the forearm in a control and heated environment. Fourteen normal male volunteers aged 20 to 31 were used as subjects. Simultaneous recordings of the …

    ubc Repository record for Cardiovascular responses to sustained isometric work in a hot environment (opens in a new tab) Download PDF for Cardiovascular responses to sustained isometric work in a hot environment (opens in a new tab)

  9. Controlling for Acute Caffeine Intake in Cardiovascular Reactivity Research

    … (SBP, DBP), mean arterial pressure (MAP), pre-ejection period (PEP), left ventricular ejection time (LVET), and total peripheral resistance (TPR). Results support the adequacy of a six-hour abstention in controlling for caffeine-elicited CVR changes. The current study contributes to …

    vt Repository record for Controlling for Acute Caffeine Intake in Cardiovascular Reactivity Research (opens in a new tab)

  10. Using Least Variance for Robust Extraction of Systolic Time Intervals

    Systolic time intervals (STI) are clinically used as non-invasive predictor of cardiovascular disease. However, algorithm accuracy generally suffers across subjects and physiological states, requiring parameter tuning for robust STI extraction. To address this challenge, an automated methodology of …

    rit Repository record for Using Least Variance for Robust Extraction of Systolic Time Intervals (opens in a new tab)

  11. ΔΟΚΙΜΑΣΙΑ ΦΑΙΝΥΛΕΦΡΙΝΗΣ-ΣΥΣΤΟΛΙΚΩΝ ΔΙΑΣΤΗΜΑΤΩΝ ΤΗΣ ΑΡΙΣΤΕΡΗΣ ΚΟΙΛΙΑΣ ΣΤΗΝ ΑΝΙΧΝΕΥΣΗ ΑΣΘΕΝΩΝ ΥΨΗΛΟΥ ΚΙΝΔΥΝΟΥ ΜΕΤΑ ΑΠΟ ΟΞΥ ΕΜΦΡΑΓΜΑ ΤΟΥ ΜΥΟΚΑΡΔΙΟΥ

    … OF THE CHANGES IN LEFT VENTRICULAR (LV)SYSTOLIC TIME INTERVALS AFTER PHENYLEPHRINE ADMINISTRATION FOR THE DETECTION OF HIGH RISK PATIENTS SOON AFTER ACUTE MYOCARDIAL INFARCTION BY CORRELATION WITH THE ANGIOGRAPHIC AND VENTRICULOGRAPHIC FINDINGS. THE PROCEDURE WAS PERFORMED IN 76 CONSECUTIVE …

    greece Repository record for ΔΟΚΙΜΑΣΙΑ ΦΑΙΝΥΛΕΦΡΙΝΗΣ-ΣΥΣΤΟΛΙΚΩΝ ΔΙΑΣΤΗΜΑΤΩΝ ΤΗΣ ΑΡΙΣΤΕΡΗΣ ΚΟΙΛΙΑΣ ΣΤΗΝ ΑΝΙΧΝΕΥΣΗ ΑΣΘΕΝΩΝ ΥΨΗΛΟΥ ΚΙΝΔΥΝΟΥ ΜΕΤΑ ΑΠΟ ΟΞΥ ΕΜΦΡΑΓΜΑ ΤΟΥ ΜΥΟΚΑΡΔΙΟΥ (opens in a new tab)

  12. Heart sounds based monitoring.

    … picture of the patient's status over time form the basis of any successful remote monitoring system. This thesis focuses on one such physiologic sensor, namely heart sounds, for remote ambulatory monitoring. The aim of this research is to develop novel algorithms for accurate …

    umn Repository record for Heart sounds based monitoring. (opens in a new tab)

  13. Impingement and Coalescence Phenomena of Gallium-based Liquid Metal Drops in a Viscous (Non-Oxidizing) Environment

    … factor, maximum spreading factor, and contact time on surfaces. Various droplet behaviours, including deposition, rebound, and splash, were observed, identifying a mechanism for bubble entrapment during the recoiling phase. For drop splashing, the onset of splashing in a viscous medium was …

    calgary Repository record for Impingement and Coalescence Phenomena of Gallium-based Liquid Metal Drops in a Viscous (Non-Oxidizing) Environment (opens in a new tab)

  14. Evaluation échocardiographique de la fonction cardiaque chez le cheval en coliques

    … despite a persistent tachycardia. The time point during the course of septic shock when hemodynamic monitoring is used has been proven to influence outcome, allowing early goal-directed therapy in humans. Unfortunately, hemodynamic monitoring in conscious horses is often limited due to …

    liege Repository record for Evaluation échocardiographique de la fonction cardiaque chez le cheval en coliques (opens in a new tab) Restricted access

  15. Evaluation of Analytical, Pharmacokinetic and Pharmacodynamic Methods for the Study of Digoxin

    … for non-invasive measurement of left ventricular ejection time (LVET) and other systolic time intervals (STI) in beagle dogs were developed. This involved surgery for exteriorization of the carotid artery in the dogs and subsequent measurements of LVET and STI after recovery. STI, heart rate (HR) …

    vcu Repository record for Evaluation of Analytical, Pharmacokinetic and Pharmacodynamic Methods for the Study of Digoxin (opens in a new tab)

  16. Echocardiographic Assessment of the Canine Right Heart: Reference Intervals and Repeatability

    … present, the use of transpulmonic acceleration time (AT) and the ratio of transpulmonic acceleration-to-ejection time (AT:ET) to indirectly assess pulmonary artery pressure is recommended.

    vt Repository record for Echocardiographic Assessment of the Canine Right Heart: Reference Intervals and Repeatability (opens in a new tab)

  17. Stanovení krevního tlaku pomocí chytrého telefonu

    … přenosu krevního pulzu (VTT – Vascular transit time) a ejekčního času srdce (ET – Ejection time) byly v signálu PCG detekovány dvě hlavní srdeční ozvy S1 a S2. Dále byly pro metody CNN využity surové úseky signálů PPG (RGB kanály videa) a PCG o různých časových délkách. Mezi regresními přístupy …

    brno-tech Repository record for Stanovení krevního tlaku pomocí chytrého telefonu (opens in a new tab)

  18. Safety implications of a sensitivity analysis of the reactor kinetics parameters for fast breeder reactors

    … in the delayed neutron spectra during a rod ejection accident. The generalised methodology, developed by Cacuci et. al., was used to derive a set of sensitivity derivatives. This method is based on the use of adjoints so that it is not necessary to repeatedly solve the governing (kinetics) …

    vt Repository record for Safety implications of a sensitivity analysis of the reactor kinetics parameters for fast breeder reactors (opens in a new tab)

  19. Effects of Exercise Training on Heart Failure Measured Using Seismocardiography

    … of the myocardium, specifically left ventricular ejection time (LVET) and the pre-ejection period (PEP) using seismocardiography (SCG), as well as to investigate the functional health changes measured using the six-minute walk test (6MWT). Participants exercised three times per week for a period …

    regina Repository record for Effects of Exercise Training on Heart Failure Measured Using Seismocardiography (opens in a new tab) Download PDF for Effects of Exercise Training on Heart Failure Measured Using Seismocardiography (opens in a new tab)

  20. Early detection of blood loss using a noninvasive finger photoplethysmographic pulse oximetry waveform

    … for automatically detecting left ventricular ejection time (LVET) from the finger PPG waveform has been developed and verified by comparison with the LVET measured from aortic flow velocity. PPG waveform derived LVET (LVETp) and pulse transit time (PTT) were strongly correlated with aortic …

    unsw Repository record for Early detection of blood loss using a noninvasive finger photoplethysmographic pulse oximetry waveform (opens in a new tab)

Page 1 of 2