Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"elastomeric isolators"”.

  1. Adaptive Characteristics of Fiber-Reinforced Elastomeric Isolators

    … large recoverable strains. Steel-reinforced elastomeric isolators (SREIs) have been widely applied as base isolators; however, the weight and cost of SREIs have been perceived as barriers to the widespread application of base isolation. In order to alleviate these concerns, it has been …

    mcmaster Repository record for Adaptive Characteristics of Fiber-Reinforced Elastomeric Isolators (opens in a new tab)

  2. Fiber Reinforced Elastomeric Isolators for Bridge Applications

    … and substructure by implementing bearings/isolators between these two components in order to reduce the transmission of straining actions. If the elements are used only to transfer the vertical loads as well as to accommodate the rotational and/or lateral deformations then it is referred as …

    mcmaster Repository record for Fiber Reinforced Elastomeric Isolators for Bridge Applications (opens in a new tab)

  3. Advanced Numerical Modeling of Fiber-Reinforced Elastomeric Isolators (FREIs)

    Fiber-reinforced elastomeric isolators (FREIs) are relatively new type of elastomeric bearing that utilize fiber-reinforced polymer (FRP) material for the reinforcing material. FREIs have lower weight and potentially easier manufacturing process compared with conventional seismic isolators. The …

    mcmaster Repository record for Advanced Numerical Modeling of Fiber-Reinforced Elastomeric Isolators (FREIs) (opens in a new tab)

  4. The Effect of Temperature on Unbonded Fiber-Reinforced Elastomeric Isolators

    … of life. More recently, the fiber-reinforced elastomeric isolator (FREI) has been investigated as a relatively new type of isolator for the base isolation of structures. Constructed from alternating layers of elastomer and carbon-fiber cloth, FREI can be produced in large pads that can be cut …

    mcmaster Repository record for The Effect of Temperature on Unbonded Fiber-Reinforced Elastomeric Isolators (opens in a new tab)

  5. The Performance of SU-FREIs (Stable Unbonded - Fiber Reinforced Elastomeric Isolators)

    <p> Steel-reinforced elastomeric isolator (SREI) bearings are currently the most commonly used type of seismic isolators. However, high manufacturing and associated installation costs prohibit their application in ordinary residential and commercial buildings. Fiber-reinforced elastomeric isolator …

    mcmaster Repository record for The Performance of SU-FREIs (Stable Unbonded - Fiber Reinforced Elastomeric Isolators) (opens in a new tab)

  6. BASE ISOLATION USING STABLE UNBONDED FIBRE REINFORCED ELASTOMERIC ISOLATORS (SU-FREI)

    … limitations of stable unbonded fibre reinforced elastomeric isolator (SU-FREI) bearings. Vertical compression testing indicated the bearings possessed adequate vertical stiffness. Due to lack of bonding at the bearing interface surfaces rollover deformation was observed to occur during lateral …

    mcmaster Repository record for BASE ISOLATION USING STABLE UNBONDED FIBRE REINFORCED ELASTOMERIC ISOLATORS (SU-FREI) (opens in a new tab)

  7. Performance assessment of carbon-fiber reinforced elastomeric isolators incorporated with polyurethane cores

    Elastomeric isolators dissipate the earthquake energy by providing lateral flexibility, increasing public safety, and reducing the expense of rehabilitation. Steel reinforced elastomeric isolators (SREIs) are the most well-known passive earthquake protection systems which are used in widespread …

    ubc Repository record for Performance assessment of carbon-fiber reinforced elastomeric isolators incorporated with polyurethane cores (opens in a new tab)

  8. Hysteretic behaviour of steel- and fibre-reinforced elastomeric isolators fitted with superelastic shape memory alloy wire

    … types of earthquake protective mechanisms, elastomeric base isolators, also called rubber bearings (RBs), are one of the most well-known systems that are widely used in buildings and bridges. They can regulate the seismic response of structures, increase the public safety, and reduce the …

    ubc Repository record for Hysteretic behaviour of steel- and fibre-reinforced elastomeric isolators fitted with superelastic shape memory alloy wire (opens in a new tab)

  9. Analytical and experimental studies of the behaviour of equipment vibration isolators under seismic conditions

    … studies of the behaviour of equipment vibration isolators under seismic conditions are presented. A preliminary parametric study of the effect of equipment-structure interaction on the ultimate equipment response of general equipment-structure systems is considered first. The results of this …

    ubc Repository record for Analytical and experimental studies of the behaviour of equipment vibration isolators under seismic conditions (opens in a new tab)

  10. IN-SITU PERFORMANCE OF SU-FREI BRIDGE BEARINGS

    Stable Unbonded Fibre Reinforced Elastomeric Isolators (SU-FREI) have been investigated extensively for seismic applications, with over 20 years of literature supporting their use in isolation of structures as an alternative to conventional Steel Reinforced Elastomeric Isolators (SREI). Preliminary …

    mcmaster Repository record for IN-SITU PERFORMANCE OF SU-FREI BRIDGE BEARINGS (opens in a new tab)

  11. Effect of bonding variation and component combination on dynamic characteristics of compound semi-bonded carbon fiber reinforced elastomeric isolator (CSB-CFREI)

    … challenges of conventional seismic isolators, application of this protective technology has been limited to high value buildings with important and sensitive contents. To ensure widespread application of the base isolation systems for ordinary residential and commercial buildings, …

    ubc Repository record for Effect of bonding variation and component combination on dynamic characteristics of compound semi-bonded carbon fiber reinforced elastomeric isolator (CSB-CFREI) (opens in a new tab)

  12. A Study of Integrated Structural Control Systems for Multi-Hazard Response Mitigation

    … comprised of stable unbonded-fiber reinforced elastomeric isolators (SU-FREI). Tests, with and without liquid in the TLD system, were carried out to evaluate the influence of the TLD under both harmonic base excitation and earthquake excitation at various excitation amplitude levels. An …

    mcmaster Repository record for A Study of Integrated Structural Control Systems for Multi-Hazard Response Mitigation (opens in a new tab)

  13. Effect of Support Conditions on the Behavior of Elastomeric Bearings

    … the installation of special devices called isolators at the base of columns. The concept of using isolators as a practical method has evolved into reality with the development of multilayer elastomeric bearings. The elastomeric bearings sometimes feature thick steel end plates and are …

    mcmaster Repository record for Effect of Support Conditions on the Behavior of Elastomeric Bearings (opens in a new tab)

  14. Experimental Study of Unbonded Fiber Reinforced Elastomeric Bearings

    <p>Multilayer elastomeric bearings are a type of seismic isolation device that mitigates seismic damage by lengthening the fundamental period of a low-rise structure. Carbon fiber reinforced elastomeric isolators (FREIs) have been identified as a cost effective alternative to bearings reinforced …

    mcmaster Repository record for Experimental Study of Unbonded Fiber Reinforced Elastomeric Bearings (opens in a new tab)

  15. Seismic Fragility Assessment of As-built and Retrofitted Bridges using Fiber Reinforced Elastomeric Isolator

    … effectiveness of implementing recently emerged isolators such as Stable Unbonded Fiber Reinforced Elastomeric Isolators (SU-FREI) should be examined by developing analytical fragility curves of retrofitted bridges and quantifying the mitigation in the damage probability of different bridge …

    mcmaster Repository record for Seismic Fragility Assessment of As-built and Retrofitted Bridges using Fiber Reinforced Elastomeric Isolator (opens in a new tab)

  16. Evaluación del impacto de los aisladores sísmicos elastoméricos en el diseño estructural de un hospital de categoría III-1, María Auxiliadora

    La presente investigación evalúa el desempeño estructural del Bloque C del Hospital María Auxiliadora frente a cargas sísmicas, comparando una estructura convencional con otra equipada con aisladores sísmicos elastoméricos tipo LBR, con el objetivo de demostrar la mejora en el comportamiento …

    upc-peru Repository record for Evaluación del impacto de los aisladores sísmicos elastoméricos en el diseño estructural de un hospital de categoría III-1, María Auxiliadora (opens in a new tab)

  17. Evaluación de las respuestas sísmicas de cubiertas de domos reticulados de acero apoyados sobre elementos verticales considerando un sistema de aislación en la base en la región de Lima

    Los domos reticulares tienen un campo de aplicación no explorado profundamente, a pesar de la funcionalidad geométrica y estructural inherente. Los usos de estas estructuras están aún limitados por la cantidad de estudios y aplicaciones en la vida real, y mucho más aún cuando funciona en conjunto a …

    upc-peru Repository record for Evaluación de las respuestas sísmicas de cubiertas de domos reticulados de acero apoyados sobre elementos verticales considerando un sistema de aislación en la base en la región de Lima (opens in a new tab)

  18. Análisis y diseño estructural de un hospital de 6 pisos con un sistema de aislamiento sísmico en la base en Lima Metropolitana empleando dispositivos elastoméricos y deslizadores friccionales

    La costa peruana se ubica en una zona de alta actividad sísmica, lo que exige medidas de protección avanzadas para edificaciones esenciales. Dado que el diseño convencional según la norma E.030 puede ser insuficiente para garantizar la operatividad post-sismo, el objetivo principal de esta …

    upc-peru Repository record for Análisis y diseño estructural de un hospital de 6 pisos con un sistema de aislamiento sísmico en la base en Lima Metropolitana empleando dispositivos elastoméricos y deslizadores friccionales (opens in a new tab)