Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 533 for “"electrical Impedance"”.

  1. Microfluidic Electrical Impedance Spectroscopy

    … device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured …

    calpoly Repository record for Microfluidic Electrical Impedance Spectroscopy (opens in a new tab)

  2. Novel techniques for electrical impedance metrology

    L'abstract è presente nell'allegato / the abstract is in the attachment

    poli-torino Repository record for Novel techniques for electrical impedance metrology (opens in a new tab)

  3. Electrical impedance of methane flat flame

    … this work was undertaken to determine if electrical impedance measurements of the flame are a direct indication of fuel/air ratio. Previous worked measured electrical resistance of the combustion of gases in an atmospheric combustor. From this work, it was conjectured that the complex …

    wvu Repository record for Electrical impedance of methane flat flame (opens in a new tab)

  4. Electrical Impedance Tomography for deformable media

    In Electrical Impedance Tomography (EIT), electrical energy is applied and measured at the boundary of a medium to produce an image of its internal conductivity distribution. When imaging pulmonary ventilation, rib cage expansion and body posture introduce severe image artefacts in the …

    ottawa-retro Repository record for Electrical Impedance Tomography for deformable media (opens in a new tab)

  5. Geophysical Applications of Electrical Impedance Tomography

    Impedance imaging is a technique where stimulus currents are applied through electrodes to a body or the ground and measurements of the potential at other electrodes are collected. The data, along with any available prior information, are used to reconstruct an image of the conductivity …

    carleton Repository record for Geophysical Applications of Electrical Impedance Tomography (opens in a new tab)

  6. Polynomial techniques in electrical impedance tomography

    The problem associated to Electrical Impedance Tomography (EIT) is a nonlinear inverse boundary value problem with applications in science and engineering, as well as a rich mathematical structure that has motivated extensive theoretical study. In idealized theoretical settings, practical aspects …

    aalto Repository record for Polynomial techniques in electrical impedance tomography (opens in a new tab)

  7. Wideband electrical impedance spectro-tomographic imaging

    … materials may show considerable change in their electrical properties in response to an injected signal over a wide frequency range. The use of this concept to demonstrate the construction of tomographic images for a range of frequency bands is described. These can then provide a deeper …

    whiterose Download PDF for Wideband electrical impedance spectro-tomographic imaging (opens in a new tab)

  8. Electrical impedance tomography at low frequencies.

    … Biological systems demonstrate dispersions of electrical impedance characteristics at very low frequencies below 2 kHz due to the presence of membrane surrounding the cells and diffusion polarisation effects. A study was made on the feasibility of the use of low frequencies in a range of 1.12 …

    unsw Repository record for Electrical impedance tomography at low frequencies. (opens in a new tab)

  9. An approximation method for electrical impedance tomography

    Electrical impedance tomography is an imaging method with applications to geophysics and medical imaging. A new approximation is presented based on Nachman's 2-dimensional construction for closed domains. It improves upon existing approximations by extending the range of application from resolving …

    ubc Repository record for An approximation method for electrical impedance tomography (opens in a new tab) Download PDF for An approximation method for electrical impedance tomography (opens in a new tab)

  10. High fidelity imaging in electrical impedance tomography

    … the computational reconstruction of images using Electrical Impedance Tomography (EIT). EIT is an imaging method, in which electrical currents are injected through electrodes into a conducting volume and the resulting potential distribution is measured at surface electrodes. From these potentials, …

    soton Download PDF for High fidelity imaging in electrical impedance tomography (opens in a new tab)

  11. Three dimensional modelling of Electrical Impedance Tomography

    Electrical Impedance Tomography (ElT) is an emerging imaging technique with applications in the medical field and in the field of industrial process tomography (lPT). Untilrecently, data acquisition and image reconstruction schemes have been constructed with the assumption that the object being …

    salford

  12. Electrical impedance tomography for internal radiation therapy

    … radiation therapy based on the principle of electrical impedance tomography (EIT). A novel procedure utilizing brachytherapy needles as electrodes is proposed to map the internal electrical conductivity of the tissue. Since cancerous tissue exhibits different levels of conductivity than …

    uoit Repository record for Electrical impedance tomography for internal radiation therapy (opens in a new tab)

  13. Discrete mathematical models for electrical impedance tomography

    Electrical Impedance Tomography (EIT) is a non-invasive, portable and low-cost medical imaging technique. Different current patterns are injected to the surface of a conductive body and the corresponding voltages are measured also on the boundary. These mea-surements are the data used to infer the …

    oxford-brookes Repository record for Discrete mathematical models for electrical impedance tomography (opens in a new tab) Download PDF for Discrete mathematical models for electrical impedance tomography (opens in a new tab)

  14. Advances in Magnetic Resonance Electrical Impedance Mammography

    Magnetic Resonance Electrical Impedance Mammography (MREIM) is a new imaging technique under development by Wollin Ventures, Inc. in conjunction with the H. Lee Moffitt Cancer Center & Research Institute. MREIM addresses the problem of low specificity of magnetic resonance mammography and high …

    usf Repository record for Advances in Magnetic Resonance Electrical Impedance Mammography (opens in a new tab)

  15. Image Segmentation Applied to Electrical Impedance Tomography

    Electrical impedance tomography (EIT) has many significant applications and has gained popularity due to its ease of use and its non-invasiveness. While it has notable applications, EIT is severely ill-posed. Since EIT is ill-posed, various techniques have been considered to solve the inverse …

    clemson Repository record for Image Segmentation Applied to Electrical Impedance Tomography (opens in a new tab)

  16. A Current Source for Electrical Impedance Tomography

    … prototype version of the current source for electrical impedance tomography was studied. Based upon its performance, a second version of the current source was built, including various improvements designed to address the issues of this first version.</p> <p>The frequency range was extended …

    mcmaster Repository record for A Current Source for Electrical Impedance Tomography (opens in a new tab)

  17. Parallel algorithms for three dimensional electrical impedance tomography

    This thesis is concerned with Electrical Impedance Tomography (EIT), an imaging technique in which pictures of the electrical impedance within a volume are formed from current and voltage measurements made on the surface of the volume. The focus of the thesis is the mathematical and numerical …

    oxford-brookes Repository record for Parallel algorithms for three dimensional electrical impedance tomography (opens in a new tab) Download PDF for Parallel algorithms for three dimensional electrical impedance tomography (opens in a new tab)

  18. Vertical Electrical Impedance Measurements of Concrete Bridge Decks

    … and deployment of a nondestructive vertical electrical impedance (VEI) bridge deck assessment apparatus. A multichannel impedance analyzer with a moving platform is developed that can assess the deterioration state of a bridge deck without stationary traffic control. The multichannel …

    byu Repository record for Vertical Electrical Impedance Measurements of Concrete Bridge Decks (opens in a new tab) Download PDF for Vertical Electrical Impedance Measurements of Concrete Bridge Decks (opens in a new tab)

  19. Microfluidic Electrical Impedance Spectroscopy System Automation and Characterization

    … cell culture platform capable of automated electrical impedance measurements and immunofluorescence and brightfield microscopy was developed for further in-vitro cellular research intended to optimize cell culture conditions. The microfluidic system design, fabrication, automation, and …

    calpoly Repository record for Microfluidic Electrical Impedance Spectroscopy System Automation and Characterization (opens in a new tab)

Page 1 of 27