Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 91 for “"electrical stress"”.
-
Class F And Inverse Class F Power Amplifier Subject To Electrical Stress Effect
… to reduce the Drain-toSource voltage (stress). A Cascode Class F & Inverse Class F RF power amplifier were designed, and optimized in order to improve efficiency and reliability using 0.18µm CMOS technology process. A 50% decrease in the stress has been achieved in the Cascode class-F …
-
Towards a Universal Hot Carrier Degradation Model for SiGe HBTs Subjected to Electrical Stress
… regions of damage within a SiGe HBT using electrically measured data, and how these degradations can be captured in a modeling framework; and 3) design optimized SiGe HBTs that can potentially overcome some of these device-level limitations in reliability across temperature. Being able to …
-
Degradation Studies of Ultrathin Silicon Oxide Under Electrical Stress Using a Scanning Tunneling Microscope
Submitted by Jesse Garrison (jagarris@illinois.edu) on 2012-01-17T18:25:40Z No. of bitstreams: 1 1999_hetrick.pdf: 3179100 bytes, checksum: 1456c9f34957d5afe213413ca490bce8 (MD5)
-
Relaxation and the nature of electrical stress related defects in ultra-thin dioxide on silicon
The instability of defects created in ultra-thin insulator, metal-oxide-silicon devices biased in the direct tunnel regime is investigated. For the case of electron injection from the silicon substrate, nearly complete defect relaxation is observed after the bias is removed, allowing the …
-
The effect of physical exercise and electrical stress on the production of experimental myocardial necroses
Thesis (Ph. D.)--Michigan State University. Department of Health, Physical Education and Recreation, 1969
-
Incidence of peptic ulcers in adaptation to forced exercise and anxiety-producing electrical stress in adult male albino rats
Thesis (M.A.)--Michigan State University of Agriculture and Applied Science. Dept. of Health, Physical Education and Recreation, 1970
-
The role of hepatic glucose-6-phosphatase in adaptation to exercise and electrical stress in adult male albino rats
Thesis (Ph. D.)--Michigan State University of Agriculture and Applied Science. Department of Health, Physical Education and Recreation, 1965
-
The effects of electrical stress and physical activity on blood cholesterol levels, whole blood coagulation time, and several organ weights of adult male rats
Thesis (Ph. D.)--Michigan State University. Department of Health, Physical Education & Recreation, 1965
-
The effects of electrical stress and/or physical activity on the histology of the heart, thyroid, and adrenal medulla in adult male albino rats
Thesis (Ph. D.)--Michigan State University. Department of Health, Physical Education and Recreation, 1967
-
The Dielectric Properties of Mixtures of Organic Compounds and Perfluoropropane
… formed when perfluoropropane was placed under electrical stress by adding small amoutns of organic compounds such as thiophene, isopropyl mercaptan, ethyl methyl sulfide, dimethyl disulfide, carbon disulfide, and nitrobenzene. The sulfur compounds were chose because fluorine was reported to …
-
On the estimation of new life model of transformer insulation material under combined electrical and thermal stress
<p>Results of combined electrical and thermal aging and only thermal aging studies conducted on a 'fish' paper insulation material are presented in this thesis.</p><p>The model for aging has been proposed which is essentially the Arrhenius equation with a weighted factor {exp -cg/kT1 to describe …
-
Fully Solution Processed PEDOT:PSS and Silver Nanowire Semi-Transparent Electrodes for Thin Film Solar Cells
… suffer from a short lifetime when subject to electrical stress. The goals of this work were to fabricate a PEDOT:PSS electrodes without using strong acids, a silver nanowire electrode with a lifetime that can exceed 6000 hours of constant electrical stress, and use these two electrodes to …
-
Corona Induced Bond Cleavage in Gaseous Fluorocarbons
… processes of perfluorocarbon gases under electrical stress. Corona characteristics were obtained for the CF4 and C3F8 gases over a considerable period of time in the presence of additives. The substances used for additives were those for which there was existing evidence that they could …
-
A RELIABILITY STUDY ON THE EFFECTS OF HTOL AND HIGH-CURRENT DENSITY STRESS TESTING ON COMMERCIAL-GRADE VERTICAL N-TYPE PD/GAN SCHOTTKY DIODES
… barrier height inhomogeneity (BHI). First, a stress testing system capable of taking in-situ current-voltage-temperature (I-V-T) measurements while applying electrical stress was constructed. Next, a sample of commercial-grade vertical n-type palladium/gallium nitride (Pd/GaN) Schottky diodes …
-
Modeling and Detection of Stator Winding Insulation Degradation in VSI-fed Electric Machines Under High dv/dt
… Motor’s winding insulation undergoes additional electrical stress due to high voltage slew rate (dv/dt) resulted from the use of VSI, which may cause accelerated insulation degradation. To investigate and quantify this electrical stress, various modeling techniques have been proposed over the …
-
An investigation of defect formation and growth in epoxy resin using light scattering methods
… role these defects play in the mechanical and electrical failure of the polymer. Mie Theory was used in the analysis of the data throughout this thesis. Ultra clean fully degassed samples were prepared to ensure any scatterers observed were Inherent to the sample. It was discovered that …
-
EM field effects on the surface of polluted HV insulators
… Chapter 6 describes an experimental study of electrical breakdown at the edges of sessile water droplets on a PE surface subject to ac electrical stress up to of 2.0MV/m at 50 Hz. The study involves observing the motion of water droplets using a high-speed video camera operating at 3000 frames …
-
Partial discharge ageing of polymer insulation under combined AC and DC stress at elevated temperatures
… a bench-mark. It was decided to use the thermo-electrical stress to age the samples. For thermal stress, 90°C was chosen as the aging temperature for HDPE, while 90°C and 110°C were chosen for PP.;For the electrical stress, AC & DC combined voltage was used to age the samples. DC voltage was 6 …
-
Perfluorocarbons in Electrical Discharges
The use of perfluorocarbon fluids as electrical insulants focuses attention on the need for a better understanding of the behaviour of electronegative materials when subjected to electrical stress and discharge conditions. Electron affinity can play an important role, and its measurement for …
Page 1 of 5