Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 167 for “"electrocardiography (ECG)"”
-
A 018μm Cmos Transmitter for Ecg Signals
Electrocardiography (ECG) signal transmitter is the device used to transmit the electrical signals of the heart to the remote machine. These electrical signals are ECG signals caused due to electrical activities in the heart. ECG signals have very low amplitude and frequency; hence amplification of …
-
Automated Atrial Fibrillation Detection from Electrocardiogram
… (AFib) detection algorithm is presented based on Electrocardiography (ECG) signals. In particular, the spectrogram of ECG signal is used as an input to a Convolutional Neural Network (CNN) to classify normal and AFib ECG signals. This model is shown to perform well with an accuracy of 92.91% and a …
-
High-performance heterojunction FETs for bioelectrical signals monitoring
… aimed at developing advanced sensors for electrocardiography (ECG) using field-effect transistors (FETs). A novel high-performance Indium oxide/Molybdenum disulfide nanoscale FET has been introduced with high electron mobility, demonstrating excellent pH sensitivity and potential for …
-
Characterization of Ecg Signal Using Programmable System on Chip
Electrocardiography (ECG) monitor is a medical device for recording the electrical activities of the heart using electrodes placed on the body. There are many ECG monitors in the market but it is essential to find the accuracy with which they generate results. Accuracy depends on the processing of …
-
EVALUATING HURRICANE ADVISORIES USING EYE-TRACKING AND BIOMETRIC DATA
… using eye-tracking, electroencephalograms (EEG), electrocardiography (ECG), electromyography (EMG), and a survey questionnaire to support analysis of participants' objective and expressed responses to competing geovisualization products. This approach allows the investigation of biometric …
-
AN EMOTION RECOGNITION METHOD WITH LOW SPEC ECG AND EEG DEVICES
… technologies make electroencephalography and electrocardiography devices portable and more accessible. This provides new opportunities in emotion recognition area for researches and the industry. Interest of industry grows on the subject. Moreover, popularity of emotion recognition research is …
-
Integrated Circuit and System Design for Wireless Biosignal Monitoring
… for recording biological signals. Specifically electrocardiography (ECG), electromyography (EMG) and single-unit neuron recording applications are discussed. These recording techniques sense electrical potentials generated by biological functions which are then amplified and sampled using …
-
ELECTRICAL MONITOR OF PHYSICAL ACTIVITY USING BIOELECTRICAL SENSORS
… (EEG) biological signals alongside Electrocardiography (ECG or EKG) and oxygen levels to determine the thresholds of exertion for individuals. Demonstrating such a correlation between these measurements would provide a basis for future investigations into developing technologies to …
-
Developing enhanced classification methods for ECG and EEG signals
A huge amount of biomedical data such as Electrocardiography (ECG) and Electroencephalography (EEG) signals are recorded daily from human body to assess and monitor human performance and physiological condition. The analysis of these signals is important for research as well as for medical …
-
Neuroregulation in Virtual Reality
… physiological (electroencephalography [EEG] and electrocardiography [ECG]) outcomes of EEG-alpha NR in both two-dimensional (2D) and three-dimensional (VR) viewing formats. Participants were randomized to either up-regulate (alpha-up) or down-regulate (alpha-down) their EEG alpha power with …
-
A Validation Study: Fitbit Charge 2 Heart Rate Measurement at Rest and During Cognitive-Emotional Stressors
… Fitbit Charge 2 (FBC2) Heart Rate (HR) and electrocardiography (ECG) under sedentary conditions. In a sample of 32 post-secondary students, agreement was observed during rest, negative affect images, deceptive pattern solving task, and a listening task. ECG HR and FBC2 HR was sampled …
-
A NOVEL HEART RATE VARIABILITY (HRV)-BASED CLASSIFICATION FOR ATRIAL FIBRILLATION
… study on potential states of HRV in AF Electrocardiography (ECG) rhythms. The K-mean++ clustering algorithm was used on full non-overlapping 5-minute ECG segments from the Long-Term Atrial Fibrillation Database. The results suggest two main classifications of AF using the silhouette …
-
The Role Of Seniority And Self-Perceived Expertise In Ecg Monitoring
… expertise of nurses with the level of electrocardiography (ECG) knowledge. Pre-test scores and improvement in post-test scores were compared for 1,910 registered nurses based on their seniority and self-perceived expertise using Pearson correlation and Spearman's Rho. The length of …
-
Perfil clínico, eletrocardiográfico, enzimático, ecocardiográfico e histológico no infarto agudo do miocárdio: estudo experimental em cães
… exams. These dogs were evaluated by clinically, electrocardiography (ECG), ambulatory electrocardiography (AE), echocardiography (ECO), creatine kinase enzyme (CK), creatine kinase MB fraction enzyme (CK-MB) and histopathologically. The animals exhibit left ventricular chamber enlargement and …
-
Signal Modelling and Physiological Parameter Extraction for a Multisensor Handheld Cardiac Monitoring Device
… handheld cardiac monitor, integrating electrocardiography (ECG) and photoplethysmography (PPG). The use of dry-contact ECG leads is assessed for its impact on signal quality. An electrode spacing of 7mm is recommended to minimize the number of missed beats. Although reduced …
-
Autonomic nervous system approach to measure physiological arousal and assess user experience in simulation-based emergency procedure training environment
… the autonomic nervous system (ANS), specifically electrocardiography (ECG), electrodermal activities (EDA), and respiration (RSP), were used to assess physiological arousal levels for 8 different conditions of an emergency evacuation task. On average, neutral and training conditions could be …
-
PhysioMiner : a scalable cloud based framework for physiological waveform mining
… PhysioMiner is tested on a large dataset of electrocardiography (ECG) from 6000 patients in the MIMIC database. Signals are cleaned and processed, and features are extracted per period. A total of 1.2 billion heart beats were processed and 26 billion features were extracted resulting in half …
-
Levels of Emotional Awareness: A psychophysiological investigation
… (EMG), skin conductance response (SCR), and electrocardiography (ECG) as participants viewed high and low arousal pleasant, high and low arousal unpleasant and neutral International Affective Picture System (IAPS) images. Baseline ECG recordings were obtained before and after image viewing. …
-
Classification Techniques for Undersampled Electromyography and Electrocardiography
Electrophysiological signals including electrocardiography (ECG) and electromyography (EMG) are widely used in clinical environments for monitoring of patients and for diagnosis of conditions including cardiac and neuromuscular disease. Due to the wealth of information contained in these signals, …
Page 1 of 9