Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"electrode positioning"”.

  1. DEVELOPMENT OF A WEARABLE EEG SYSTEM FOR EVERYDAY USE: OVERCOMING MOTION ARTIFACTS, ELECTRODE POSITIONING, AND ON-DEVICE COMPUTING CHALLENGES

    … we developed WalkingWizard, a prototype dry-electrode EEG embedded within a baseball cap, designed for use under motion. This flexible PCB-based device contains an embedded layer in the PCB to record motion artifact, enabling high signal-to-noise ratio (SNR) EEG sensing even while in motion. …

    nus Repository record for DEVELOPMENT OF A WEARABLE EEG SYSTEM FOR EVERYDAY USE: OVERCOMING MOTION ARTIFACTS, ELECTRODE POSITIONING, AND ON-DEVICE COMPUTING CHALLENGES (opens in a new tab)

  2. Model-driven stimulation for targeted functional restoration in chronic spinal cord injury

    … targeting is possible, what the optimal electrode position is or how to account for inter-individual differences in anatomy. Answering these questions requires the ability to model the effects of variations in electrode positions and stimulation parameters on detailed models of individual …

    oxford Repository record for Model-driven stimulation for targeted functional restoration in chronic spinal cord injury (opens in a new tab)

  3. Advanced control methodologies for atmospheric pressure plasmas used for materials synthesis

    … Slight variations in voltage, gas flow or electrode positioning can significantly alter the discharge dynamics, leading to considerable variations in nanoparticle properties. In addition, the volatile and highly reactive species formed at the interfaces between plasma and liquid make …

    whiterose Download PDF for Advanced control methodologies for atmospheric pressure plasmas used for materials synthesis (opens in a new tab)

  4. A Comparison of ICA versus genetic algorithm optimized ICA for use in non-invasive muscle tissue EMG

    … monopolar surface Electromyography (sEMG) electrodes and a Blind Source Separation algorithm. This concept was then proved by Morowasi and John [2] in a 12 electrode prototype system around the bicep. This proof of concept showed that it was possible to extract the deep tissue activity of …

    cape-town Repository record for A Comparison of ICA versus genetic algorithm optimized ICA for use in non-invasive muscle tissue EMG (opens in a new tab)

  5. Ανάπτυξη τομογραφικών γεωφυσικών τεχνικών για τη μελέτη γεωτεχνικών και περιβαλλοντικών προβλημάτων

    … resistivity tomography, employing a special electrode array. In this array, one electrode row is placed on the surface and another one is probed into the earth. This array is labeled as ‘surface-to-tunnel’ which has two rows of electrodes running parallel while the ‘interior’ row is placed …

    greece Repository record for Ανάπτυξη τομογραφικών γεωφυσικών τεχνικών για τη μελέτη γεωτεχνικών και περιβαλλοντικών προβλημάτων (opens in a new tab)

  6. Facilitating the incorporation of neuroscience methods and knowledge into brain-computer interfaces

    … variance due to head anatomy, brain anatomy, and electrode positioning, and could train a subject-independent BCI with higher accuracy than the traditional subject-dependent model despite using no training data from the subject of interest. Third, we explored functional connectivity to generate …

    washington Repository record for Facilitating the incorporation of neuroscience methods and knowledge into brain-computer interfaces (opens in a new tab)

  7. Finite Element Study of Transcranial Direct Current Stimulation: customization of models and montages

    … technique that applies low amplitude current via electrodes placed on the scalp. Rather than directly eliciting a neuronal response, tDCS is believed to modulate excitability – encouraging or suppressing activity in regions of the brain depending on the polarity of stimulation. The particular …

    cuny Repository record for Finite Element Study of Transcranial Direct Current Stimulation: customization of models and montages (opens in a new tab)

  8. Two-channel surface stimulation for the correction of drop foot.

    … transcutaneous FES systems require the accurate positioning of surface electrodes on the skin so that the appropriate nerves are activated to give the desired muscle response. Many people find electrode positioning difficult. 2 This project examined the feasibility of using two channels of …

    bournemouth Download PDF for Two-channel surface stimulation for the correction of drop foot. (opens in a new tab)

  9. Eine Methode zur nichtinvasiven EEG-Ableitung am wachen, stehenden Pferd

    … situation of the skull of the horse an electrode holding cape was developed. The uniform and easy repeatable electrode positioning makes it possible to register the EEG free of pain for the animal by using skin electrodes. In order to obtain an appropriate display of the EEG-activity as …

    fu-berlin Repository record for Eine Methode zur nichtinvasiven EEG-Ableitung am wachen, stehenden Pferd (opens in a new tab)

  10. IMPROVING THE EFFICIENCY OF FES FOR UPPER LIMB REHABILITATION AFTER STROKE

    … to challenges in manually identifying accurate electrode positions for the desired movement.-It cannot automatically compensate for fatigue, requiring frequent manual adjustments by therapists (Waring K, 2020).The PhD aimed to:-Develop an improved electrode positioning method and-Develop an …

    salford Repository record for IMPROVING THE EFFICIENCY OF FES FOR UPPER LIMB REHABILITATION AFTER STROKE (opens in a new tab) Embargoed until 2027-05-30

  11. Electrochemical Investigation of Anthraquinone tagged Oligonucleotides and Electrodes

    … described were applied using modified electrodes and modified nucleotides included in the DNA sequences.</p> <p>The first study examines the use of an anthraquinone-modified uridine nucleotide. This nucleotide was included in the synthesis of a DNA pentamer and a set of 20mers varying …

    utk-theses Repository record for Electrochemical Investigation of Anthraquinone tagged Oligonucleotides and Electrodes (opens in a new tab)

  12. Advancing Electrical Stimulation: Full-Head MRI Segmentation for Abnormal Brain Anatomy with tDCS

    … muscles. To optimize stimulation parameters and electrode placement, our laboratory developed ROAST (Realistic vOlumetric-Approach-based Simulator for Transcranial electric stimulation), a software tool for simulating current flow in the brain. However, ROAST's performance is highly dependent on …

    cuny Repository record for Advancing Electrical Stimulation: Full-Head MRI Segmentation for Abnormal Brain Anatomy with tDCS (opens in a new tab)

  13. A comparison of tri-polar concentric ring electrodes to disc electrodes for decoding real and imaginary finger movements

    … spatial resolution. Tri-polar concentric ring electrodes (TCREs) have been shown to estimate the surface Laplacian automatically with better spatial resolution than conventional disc electrodes. The aim of this research is to study how well the TCREs can be used to acquire EEG signals to decode …

    colostate Repository record for A comparison of tri-polar concentric ring electrodes to disc electrodes for decoding real and imaginary finger movements (opens in a new tab)

  14. SUSTAINABILITY, ENERGY AND ANIMAL WELFARE AT SLAUGHTER

    … in lambs. Key parameters considered included electrode positioning, the duration of current application, and the stun-to-stick interval under field conditions. The project comprises three key studies: • Study 1: A systematic review critically evaluated the feasibility of ABMs for assessing …

    milano Repository record for SUSTAINABILITY, ENERGY AND ANIMAL WELFARE AT SLAUGHTER (opens in a new tab)

  15. Large scale neuronal recording

    … means supplanting single unit recording with electrodes capable of monitoring the activity of hundreds, and ultimately thousands, of neurons simultaneously. Conducting experiments on one or a few neurons at a time and then making elaborate conclusions or models based on these piecewise …

    ubc Repository record for Large scale neuronal recording (opens in a new tab) Download PDF for Large scale neuronal recording (opens in a new tab)

  16. Computational Modeling of Epidural Cortical Stimulation: Design, Analysis, and Experimental Evaluation

    … in the cortex and how these effects vary with electrode geometry and location as well as the electrical and geometrical properties of the anatomy.</p><p>The effects of ECS on cortical neurons were investigated using a three dimensional computational model of the human precentral gyrus and …

    duke Repository record for Computational Modeling of Epidural Cortical Stimulation: Design, Analysis, and Experimental Evaluation (opens in a new tab)

  17. An EEG Investigation of Sound Source Elevation Processing and Prediction in Mice

    … that allows for automated skull drilling and electrode array placement with micrometer-level precision. In the EEG systems section, we delineate the two types of EEG apparatus used in the experiments: subcutaneous needle electrodes (SNE) and multielectrode array (MEA). We discuss the …

    qucosa-diss