Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 22 for “"electrode-tissue interface"”
-
The Electrode-Tissue Interface during Recording and Stimulation in the Central Nervous System
… assumed that the long-term functionality of electrodes used for recording and stimulation in the central nervous system (CNS) is highly dependent on the composition of the electrode-tissue interface (ETI). The ETI consists of various ions, proteins, and cells adhered directly to the electrode …
-
Analysis and Design of Electrodes for Deep Brain Stimulation
<p>Deep brain stimulation (DBS) electrodes are intended to stimulate specific areas of the brain to treat movement disorders including essential tremor, Parkinson's disease and dystonia. An important goal in the design of next generation DBS electrodes is to minimize the power needed to stimulate …
-
DESIGN AND MATERIALS DEVELOPMENT OF A SELF-CONTAINED FREEFORM STIMULATOR FOR NON-PULSATILE NEUROMODULATION
… biphasic pulses due to safety constraints at the electrode-tissue interface. Maintaining zero net charge injection minimizes the risk of electrochemical reactions that can damage both the electrode and surrounding tissue. However, pulsatile stimulation primarily evokes phase-locked excitation, …
-
Design of a Quasi-Adiabatic Current-Mode Neurostimulator Integrated Circuit for Deep Brain Stimulation
Electrical stimulation of neural tissues is a valuable tool in the retinal prosthesis, cardiac pacemakers, and Deep Brain Stimulation (DBS). DBS is being to treat a growing number of neurological disorders, such as movement disorder, epilepsy, and Parkinson’s disease. The role of the electronic …
-
Chronic intracortical electrodes: Modulation of the blood-brain barrier and the functional implications
Brain machine interfaces have the potential to connect patients living with paralysis to prosthetics and devices, dramatically improving quality of life. Intracortical electrodes provide the electrode-tissue interface and record action potentials from neurons. Over time, the strength of the …
-
An analysis of parasitic capacitances in ioimpedance spectroscopy and their impact on impedance measurements
… dependent electrical properties of biological tissues. Typically termed BioImpedance Spectroscopy, or BIS, these measurements are used in many medical and fitness-related applications. However, many of these measurements suffer from a "hook-artifact", or erroneous increase in reactance at high …
-
Interfacing the brain: high-channel-count neural recording and minimally invasive brain stimulation ASICs
… Specialized tools, particularly neural interfaces, are crucial in this pursuit. These interfaces act as communication pathways between the brain and external devices. My research addresses two critical areas: high-channel-count neural recording and minimally invasive neural stimulation. …
-
Towards Biocompatible Designs and Strategies for Minimizing Tissue Trauma at the Neural Interface
… or result in undesirable side effects. Neural interfaces enable physicians to electrically “communicate” with the nervous system and influence its activity. Despite advancements in neural interfaces, the placement of implantable devices during and after surgery poses additional risks when …
-
Development of Tools for a 3D Reconstructed Intracortical Volume Around Microelectrode Arrays
Extensive research using penetrating electrodes implanted in the central and peripheral nervous systems has been performed for many decades with significant advances made in recent years. While these penetrating devices provide proximity to individual neurons in-vivo and perform effectively for …
-
MICROELECTRODE ARRAY FOR CAPACITIVE TRANSDUCTION OF RETINAL RESPONSES
… motivating the development of neural prosthetic interfaces to restore sensory or motor function in affected individuals. Advances in neural sensing and stimulation interface technology will allow a more comprehensive understanding of neural function while leading to the development of hybrid …
-
Design and development of a fluid actuated neural probe for chronic sensing
… brain dysfunction for brain-machine interfaces and in neuroscience studies for interrogation of neural tissue. The performance of implantable neural probes for chronic applications has been hampered, owing to an inflammatory immune response in the vicinity of the implanted devices, …
-
Design and development of a fluid actuated neural probe for chronic sensing
… brain dysfunction for brain-machine interfaces and in neuroscience studies for interrogation of neural tissue. The performance of implantable neural probes for chronic applications has been hampered, owing to an inflammatory immune response in the vicinity of the implanted devices, …
-
A dynamic model of radio frequency catheter ablation for the treatment of cardiac arrhythmias.
… RF ablation. This model included the effects of tissue and electrode heat conduction, tissue perfusion, and the convective losses within the heart chamber. Results indicated that the convective effects of blood flow within the heart chamber over the catheter were significant. More power could be …
-
A vision prosthesis neurostimulator: progress towards the realisation of a neural prosthesis for the blind
… issues due to an unknown or changing combined tissue and electrode/tissue interface impedance; simultaneous stimulation using current sources and sinks, with return electrodes configured to provide maximum charge containment at each stimulation site; stimuli delivered to a two dimensional …
-
Microfluidics and Neural Interfaces Development for the Safe Direct Current Stimulator
… to interact with target neurons using metal electrodes. Short biphasic pulses are used to avoid toxic electrochemical reactions at the electrode-tissue interfaces. Biphasic pulses are effective at exciting neurons, but quite limited in inhibiting their activity. In contrast, direct current …
-
High-Voltage Compliant, Electrode-Invariant Neural Stimulation Electronics Compatible with Low-Voltage, Bulk-CMOS Integration
… practical, electrical neural stimulation interfaces using modern silicon CMOS technologies. To overcome said challenges, which stem from the discrepancy between the low-voltage limitations of modern CMOS devices and the large stimulation voltages often observed at response-evoking stimulus …
-
Development and Evaluation of Dry-Contact Electroencephalography (EEG) Sensors
… with dry-contact sensors indicates the unknown electrode-tissue impedance (ETI) is arguably the most difficult to deal with. While there are many modern techniques that aim to reduce the effects of the unknown ETI, none are regarded as extremely successful methods. Thus, researchers at the …
-
Cortical surface recurrent brain-computer interfaces
The output of a "traditional" brain computer-interface (BCI) is the operation of an effector mechanism, like a cursor or a prosthetic arm. In contrast, the output of a recurrent brain-computer interface (rBCI) is electrical stimulation delivered directly into the central nervous system (CNS). …
-
Effects of Dip-coated films on the Properties of Implantable Intracortical Microelectrodes
… clinical use of implantable intracortical microelectrodes (ICMs) to treat certain types of deafness, blindness, and paralysis is limited by a reactive tissue response (RTR) of the brain. This RTR culminates in the formation of a tight glial scar and a loss of neuronal density around implanted …
-
An implantable micro-system for neural prosthesis control and sensory feedback restoration in amputees
… the prototype of an electronic bi-directional interface between the Peripheral Nervous System (PNS) and a neuro-controlled hand prosthesis is presented. The system is composed of two Integrated Circuits (ICs): a standard CMOS device for neural recording and a High Voltage (HV) CMOS device for …
Page 1 of 2