Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 22 for “"electrode-tissue interface"”

  1. The Electrode-Tissue Interface during Recording and Stimulation in the Central Nervous System

    … assumed that the long-term functionality of electrodes used for recording and stimulation in the central nervous system (CNS) is highly dependent on the composition of the electrode-tissue interface (ETI). The ETI consists of various ions, proteins, and cells adhered directly to the electrode …

    ohiolink Repository record for The Electrode-Tissue Interface during Recording and Stimulation in the Central Nervous System (opens in a new tab)

  2. Analysis and Design of Electrodes for Deep Brain Stimulation

    <p>Deep brain stimulation (DBS) electrodes are intended to stimulate specific areas of the brain to treat movement disorders including essential tremor, Parkinson's disease and dystonia. An important goal in the design of next generation DBS electrodes is to minimize the power needed to stimulate …

    duke Repository record for Analysis and Design of Electrodes for Deep Brain Stimulation (opens in a new tab)

  3. DESIGN AND MATERIALS DEVELOPMENT OF A SELF-CONTAINED FREEFORM STIMULATOR FOR NON-PULSATILE NEUROMODULATION

    … biphasic pulses due to safety constraints at the electrode-tissue interface. Maintaining zero net charge injection minimizes the risk of electrochemical reactions that can damage both the electrode and surrounding tissue. However, pulsatile stimulation primarily evokes phase-locked excitation, …

    jhu Repository record for DESIGN AND MATERIALS DEVELOPMENT OF A SELF-CONTAINED FREEFORM STIMULATOR FOR NON-PULSATILE NEUROMODULATION (opens in a new tab)

  4. Design of a Quasi-Adiabatic Current-Mode Neurostimulator Integrated Circuit for Deep Brain Stimulation

    Electrical stimulation of neural tissues is a valuable tool in the retinal prosthesis, cardiac pacemakers, and Deep Brain Stimulation (DBS). DBS is being to treat a growing number of neurological disorders, such as movement disorder, epilepsy, and Parkinson’s disease. The role of the electronic …

    maryland Repository record for Design of a Quasi-Adiabatic Current-Mode Neurostimulator Integrated Circuit for Deep Brain Stimulation (opens in a new tab)

  5. Chronic intracortical electrodes: Modulation of the blood-brain barrier and the functional implications

    Brain machine interfaces have the potential to connect patients living with paralysis to prosthetics and devices, dramatically improving quality of life. Intracortical electrodes provide the electrode-tissue interface and record action potentials from neurons. Over time, the strength of the …

    gatech Repository record for Chronic intracortical electrodes: Modulation of the blood-brain barrier and the functional implications (opens in a new tab)

  6. An analysis of parasitic capacitances in ioimpedance spectroscopy and their impact on impedance measurements

    … dependent electrical properties of biological tissues. Typically termed BioImpedance Spectroscopy, or BIS, these measurements are used in many medical and fitness-related applications. However, many of these measurements suffer from a "hook-artifact", or erroneous increase in reactance at high …

    alabama Repository record for An analysis of parasitic capacitances in ioimpedance spectroscopy and their impact on impedance measurements (opens in a new tab)

  7. Interfacing the brain: high-channel-count neural recording and minimally invasive brain stimulation ASICs

    … Specialized tools, particularly neural interfaces, are crucial in this pursuit. These interfaces act as communication pathways between the brain and external devices. My research addresses two critical areas: high-channel-count neural recording and minimally invasive neural stimulation. …

    rice Repository record for Interfacing the brain: high-channel-count neural recording and minimally invasive brain stimulation ASICs (opens in a new tab) Embargoed until 2026-12-01

  8. Towards Biocompatible Designs and Strategies for Minimizing Tissue Trauma at the Neural Interface

    … or result in undesirable side effects. Neural interfaces enable physicians to electrically “communicate” with the nervous system and influence its activity. Despite advancements in neural interfaces, the placement of implantable devices during and after surgery poses additional risks when …

    ohiolink Repository record for Towards Biocompatible Designs and Strategies for Minimizing Tissue Trauma at the Neural Interface (opens in a new tab)

  9. Development of Tools for a 3D Reconstructed Intracortical Volume Around Microelectrode Arrays

    Extensive research using penetrating electrodes implanted in the central and peripheral nervous systems has been performed for many decades with significant advances made in recent years. While these penetrating devices provide proximity to individual neurons in-vivo and perform effectively for …

    uconn-diss Repository record for Development of Tools for a 3D Reconstructed Intracortical Volume Around Microelectrode Arrays (opens in a new tab)

  10. MICROELECTRODE ARRAY FOR CAPACITIVE TRANSDUCTION OF RETINAL RESPONSES

    … motivating the development of neural prosthetic interfaces to restore sensory or motor function in affected individuals. Advances in neural sensing and stimulation interface technology will allow a more comprehensive understanding of neural function while leading to the development of hybrid …

    unm Repository record for MICROELECTRODE ARRAY FOR CAPACITIVE TRANSDUCTION OF RETINAL RESPONSES (opens in a new tab)

  11. Design and development of a fluid actuated neural probe for chronic sensing

    … brain dysfunction for brain-machine interfaces and in neuroscience studies for interrogation of neural tissue. The performance of implantable neural probes for chronic applications has been hampered, owing to an inflammatory immune response in the vicinity of the implanted devices, …

    umn Repository record for Design and development of a fluid actuated neural probe for chronic sensing (opens in a new tab)

  12. Design and development of a fluid actuated neural probe for chronic sensing

    … brain dysfunction for brain-machine interfaces and in neuroscience studies for interrogation of neural tissue. The performance of implantable neural probes for chronic applications has been hampered, owing to an inflammatory immune response in the vicinity of the implanted devices, …

    umn Repository record for Design and development of a fluid actuated neural probe for chronic sensing (opens in a new tab)

  13. A dynamic model of radio frequency catheter ablation for the treatment of cardiac arrhythmias.

    … RF ablation. This model included the effects of tissue and electrode heat conduction, tissue perfusion, and the convective losses within the heart chamber. Results indicated that the convective effects of blood flow within the heart chamber over the catheter were significant. More power could be …

    arizona-thes Repository record for A dynamic model of radio frequency catheter ablation for the treatment of cardiac arrhythmias. (opens in a new tab)

  14. A vision prosthesis neurostimulator: progress towards the realisation of a neural prosthesis for the blind

    … issues due to an unknown or changing combined tissue and electrode/tissue interface impedance; simultaneous stimulation using current sources and sinks, with return electrodes configured to provide maximum charge containment at each stimulation site; stimuli delivered to a two dimensional …

    unsw Repository record for A vision prosthesis neurostimulator: progress towards the realisation of a neural prosthesis for the blind (opens in a new tab)

  15. Microfluidics and Neural Interfaces Development for the Safe Direct Current Stimulator

    … to interact with target neurons using metal electrodes. Short biphasic pulses are used to avoid toxic electrochemical reactions at the electrode-tissue interfaces. Biphasic pulses are effective at exciting neurons, but quite limited in inhibiting their activity. In contrast, direct current …

    jhu Repository record for Microfluidics and Neural Interfaces Development for the Safe Direct Current Stimulator (opens in a new tab)

  16. High-Voltage Compliant, Electrode-Invariant Neural Stimulation Electronics Compatible with Low-Voltage, Bulk-CMOS Integration

    … practical, electrical neural stimulation interfaces using modern silicon CMOS technologies. To overcome said challenges, which stem from the discrepancy between the low-voltage limitations of modern CMOS devices and the large stimulation voltages often observed at response-evoking stimulus …

    washington Repository record for High-Voltage Compliant, Electrode-Invariant Neural Stimulation Electronics Compatible with Low-Voltage, Bulk-CMOS Integration (opens in a new tab)

  17. Development and Evaluation of Dry-Contact Electroencephalography (EEG) Sensors

    … with dry-contact sensors indicates the unknown electrode-tissue impedance (ETI) is arguably the most difficult to deal with. While there are many modern techniques that aim to reduce the effects of the unknown ETI, none are regarded as extremely successful methods. Thus, researchers at the …

    auckland-tech Repository record for Development and Evaluation of Dry-Contact Electroencephalography (EEG) Sensors (opens in a new tab)

  18. Cortical surface recurrent brain-computer interfaces

    The output of a "traditional" brain computer-interface (BCI) is the operation of an effector mechanism, like a cursor or a prosthetic arm. In contrast, the output of a recurrent brain-computer interface (rBCI) is electrical stimulation delivered directly into the central nervous system (CNS). …

    washington Repository record for Cortical surface recurrent brain-computer interfaces (opens in a new tab)

  19. Effects of Dip-coated films on the Properties of Implantable Intracortical Microelectrodes

    … clinical use of implantable intracortical microelectrodes (ICMs) to treat certain types of deafness, blindness, and paralysis is limited by a reactive tissue response (RTR) of the brain. This RTR culminates in the formation of a tight glial scar and a loss of neuronal density around implanted …

    purdue-thes Repository record for Effects of Dip-coated films on the Properties of Implantable Intracortical Microelectrodes (opens in a new tab)

  20. An implantable micro-system for neural prosthesis control and sensory feedback restoration in amputees

    … the prototype of an electronic bi-directional interface between the Peripheral Nervous System (PNS) and a neuro-controlled hand prosthesis is presented. The system is composed of two Integrated Circuits (ICs): a standard CMOS device for neural recording and a High Voltage (HV) CMOS device for …

    cagliari Repository record for An implantable micro-system for neural prosthesis control and sensory feedback restoration in amputees (opens in a new tab)

Page 1 of 2