Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"electromagnetic coil"”.
-
ANALYSIS AND IMPEDANCE-BASED DETECTION OF ELECTROMAGNETIC COIL INSULATION DEGRADATION
Electromagnetic induction coils are widely used in a variety of applications, such as motors, solenoid valves, and relays. Many of these applications are safety-critical. Failure of the insulation that protects the windings in electromagnetic coils is a significant cause of coil failure and can …
-
Manipulating Cells with a Dynamically Reconfigurable Electro-magnetic Coil
… field generated by a dynamically-reconfigurable electromagnetic coil. The magnetic field will push away the non-magnetic objects (including cancer cells) so that they can be potentially trapped, manipulated, and directed towards a specific location. In this research, we developed the …
-
Modeling and Control of a Single-Axis Magnetic Levitation System Using LabVIEW
… The tabletop maglev system consists of an electromagnetic coil as the actuator that levitates a ferromagnetic object while an infrared sensor is used to determine the object's position. Based on the sensor output, the controller adjusts the current in the coil which in tum adjusts the …
-
Characterization of Printed Planar Electromagnetic Coils Using Digital Extrusion and Roll-to-Roll Flexographic Processes
… led to increased interest in using flat, planar electromagnetic coils, which have been shown to perform better at scaled down sizes. The two-dimensional geometry of a planar electromagnetic coil yields itself to be produced by a roll-to-roll additive manufacturing process. The emergence of the …
-
A numerical and experimental investigation of vibratory bowl feeders
… the asymmetrical arrangement of the springs and electromagnetic coil relative to each other; and vii) Solutions proposed to the problem of dead-spots were the use of four spring banks instead of three, and the specification of an annular shaped pole piece for the electromagnetic coil.
-
THE DEVELOPMENT AND EVALUATION OF A HIGH-POWER MAGNETIC ROBOTIC SURGERY PLATFORM
… tissues. It is important to optimize the magnet coil design for the workspace to ensure maximum force given the power and physical constraints to enable high-force procedures. Here is a proposed solution utilizing a sloped and stacked triple-coil electromagnetic coil platform. The coil design is …
-
Magnetic Imaging of Micrometer and Nanometer-size Magnetic Structures and Their Flux-Pinning Effects on Superconducting Thin Films
… curves. An additional sharp magnetic needle and electromagnetic coil assembly intended for micromanipulation of small magnetic particles and individual cells was also characterized.
-
Elektromagnetinio mechaninių virpesių žadinimo stalelio tyrimas /
… of electrodynamic vibration test bench is electromagnetic coil. The test subject is moved by Ampere's force which is created by electric current flowing through the coil. By changing the current, the test subject changes it's amplitude, speed and acceleration. Considering the fact that …
-
Superconductors and high magnetic fields
… wire’s parameters. Design of a high field pulsed electromagnetic coil for flux trapping in superconductors. This section details the design, construction and testing of a novel pulsed high field magnet. The design uses finite element analysis to predict the electromagnetic, thermal and structural …
-
Insect Powered Micro Air Vehicles And Centimeter Scale High Energy Density Pneumatic Sources
… high fluidic resistance at high pressures. Electromagnetic coil valves were fabricated to control CO2 flow from 10-20 micron diameter glass capillaries that could actuate surface micromachined polysilicon micromotors.
-
Neural Mechanisms of Transcranial Magnetic Stimulation in the Treatment of Tinnitus
… modeling the function of a miniature magnetic coil that can be used for TMS in rodents, ii) establishing a reliable mouse model of tinnitus that can be used for assessing TMS treatment-induced changes, iii) measuring the behavioral alterations and neural changes induced by TMS throughout the …
-
A Novel Electromagnetic Technique for Remote Repositioning of Coolant Tube Spacers In CANDU Nuclear Reactors
… locations. This Thesis describes a novel electromagnetic method to reposition without the garter springs without dismantling the fuel channels. The method consists of inserting an electromagnetic coil into the pressure tube to a location adjacent to the spacer and passing a time-varying …
-
Design, Optimization, and Experimental Characterization of a Novel Magnetically Actuated Finger Micromanipulator
… in many fields. Conversely, major drawbacks of electromagnetic micromanipulators, include a limited motion range compared to the micromanipulator volume, the inability to handle heavy payloads, and the need for a large drive unit compared to the size of the levitated object, and finally, a low …
-
RELIABLE AUTONOMY FOR MAGNETIC SURGICAL ROBOTS
… permanent magnets. However, fields generated by electromagnetic coil arrays are strongly nonlinear, particularly near the coils, where commonly used dipole approximations can exhibit large errors. Because magnetic forces and torques decay approximately with the inverse cube of distance, modeling …
-
NÁVRH NDT METODY PRO HODNOCENÍ DRÁTKOBETONU
Dizertační práce se zabývá návrhem nedestruktivní metody testování (NDT) určené pro hodnocení rovnoměrnosti rozložení a stanovení koncentrace ocelových drátků v drátkobetonu. V současné době na poli diagnostiky stavebních konstrukcí není dostupná žádná nedestruktivní metoda umožňující hodnotit …