Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"electron signals"”.

  1. DEVELOPMENT AND CHARACTERIZATION OF AN INNOVATIVE LOW-NOISE HIGH-DYNAMIC-RANGE VLSI CHARGE-SENSITIVE PREAMPLIFIER FOR SOLID-STATE DETECTORS EMPLOYED IN NUCLEAR PHYSICS EXPERIMENTS WITH RADIOACTIVE ION BEAMS

    … four channels specifically designed for hole signals and one channel for electron signals. The power consumption is around 10 mW per channel as required by the specifications of TRACE. The main design goals are low noise and fast rise time. With proper shaping of the signals this device is …

    milano Repository record for DEVELOPMENT AND CHARACTERIZATION OF AN INNOVATIVE LOW-NOISE HIGH-DYNAMIC-RANGE VLSI CHARGE-SENSITIVE PREAMPLIFIER FOR SOLID-STATE DETECTORS EMPLOYED IN NUCLEAR PHYSICS EXPERIMENTS WITH RADIOACTIVE ION BEAMS (opens in a new tab)

  2. Field emission regime of the scanning tunnelling microscope

    … capable of probing nanoscale variations in local electronic structure. Operating in the field emission regime of a dual-mode STM system, SFEM enables high-resolution mapping of absorbed and secondary electron signals, offering complementary contrast mechanisms to conventional STM at higher …

    whiterose Download PDF for Field emission regime of the scanning tunnelling microscope (opens in a new tab)

  3. Real-time, upstream, radiotherapy verification using a CMOS Monolithic Active Pixel Sensor System

    … to separate therapeutic photon and contaminant electron signals. A grating-friendly reconstruction algorithm was developed, achieving worst resolutions of 68 . 59 ± 10. 75 μm for a 10 × 10 cm2 field and 109. 5 ± 24. 7 μm for a 40 × 40 cm2 field.<br/><br/>The system’s performance was validated …

    bristol Repository record for Real-time, upstream, radiotherapy verification using a CMOS Monolithic Active Pixel Sensor System (opens in a new tab) Download PDF for Real-time, upstream, radiotherapy verification using a CMOS Monolithic Active Pixel Sensor System (opens in a new tab)

  4. A measurement of the rate of muon capture in an ultra-pure protium gas time projection chamber

    … caused by interference between muon track and electron signals in the TPC gas. The stability of the disappearance rate with respect to the analysis choices is demonstrated. The remaining systematic studies are summarized, and a relative comparison of L_S between the 2006 and 2007 data sets is …

    uiuc Repository record for A measurement of the rate of muon capture in an ultra-pure protium gas time projection chamber (opens in a new tab)

  5. Approaches to Industry 4.0 implementation for electron beam quality assurance using BeamAssure

    Electron beam welding (EBW) is a complex process used in manufacturing high-value components in the aerospace and nuclear industries. The Fourth Industrial Revolution is a fusion of advances in artificial intelligence, sensing techniques, data science, and other technologies to improve productivity …

    lancaster Download PDF for Approaches to Industry 4.0 implementation for electron beam quality assurance using BeamAssure (opens in a new tab)

  6. A high-repetition-rate ultrafast electron diffraction setup with direct detection for solid-state samples

    … description and analysis of an ultrafast electron diffraction (UED) instrument, with a focus on the optical configuration and the components that generate, propagate, and detect the electron beam. We have successfully produced a stable, high-quality electron beam with sufficient transverse …

    fu-berlin Repository record for A high-repetition-rate ultrafast electron diffraction setup with direct detection for solid-state samples (opens in a new tab)

  7. Vliv změn geometrie detektoru ISEDS na kompozici detekovaného signálu

    Bakalářská práce se věnuje ionizačnímu detektoru sekundárních elektronů s elektrostatickým separátorem využívaným v environmentální skenovací elektronové mikroskopii. Za využití numerických simulací byl zkoumán vliv elektrostatického pole, prostorového rozložení hustoty plynu a geometrických …

    brno-tech Repository record for Vliv změn geometrie detektoru ISEDS na kompozici detekovaného signálu (opens in a new tab)