Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"electron therapy"”.

  1. Dose Calculation For Electron Therapy

    The dose delivered by electron beams has a complex dependence on the shape of the field; any field shaping shields, design of collimator systems, and energy of the beam. This complicated dependence is due to multiple scattering of the electron beam as the beam travels from the accelerator head to …

    south-carolina Repository record for Dose Calculation For Electron Therapy (opens in a new tab)

  2. Dynamic Electron Arc Radiotherapy (DEAR): A New Conformal Electron Therapy Technique

    <p>Electron beam therapy represents an underutilized area in radiation therapy. While electron radiation therapy has existed for many decades and electron beams with multiple energies are available on linear accelerators – the most common device to deliver radiation therapy – efforts to advance the …

    duke Repository record for Dynamic Electron Arc Radiotherapy (DEAR): A New Conformal Electron Therapy Technique (opens in a new tab)

  3. Radiotherapy in a FLASH : Towards clinical translation of ultra-high dose rate electron therapy

    FLASH radiotherapy (FLASH-RT) is a promising new approach to radiotherapy that has the potential to transform the field. By administering radiation at ultra-high dose rates (UHDR) on a millisecond timescale, FLASH-RT may increase normal tissue tolerance compared to conventional radiotherapy while …

    lund Repository record for Radiotherapy in a FLASH : Towards clinical translation of ultra-high dose rate electron therapy (opens in a new tab) Download PDF for Radiotherapy in a FLASH : Towards clinical translation of ultra-high dose rate electron therapy (opens in a new tab)

  4. Production of ¹⁶⁵Er : a promising candidate for SPECT imaging and targeted Auger electron therapy of cancer

    Auger electron-emitting (AEE) radionuclides with low (0.001–1 keV) energy, short range (2-500 nm), and high linear energy transfer (4–26 keV/μm) can play an important role in the targeted radionuclide therapy (TRT) of cancer. ¹⁶⁵Er (t₁/₂=10.36 h) decays 100% via electron capture and is one of a few …

    ubc Repository record for Production of ¹⁶⁵Er : a promising candidate for SPECT imaging and targeted Auger electron therapy of cancer (opens in a new tab) Download PDF for Production of ¹⁶⁵Er : a promising candidate for SPECT imaging and targeted Auger electron therapy of cancer (opens in a new tab)

  5. Design and Validation of a Prototype Collimation System with Reduced Applicator Weights for Elekta Electron Therapy Beams

    The objective of this study was to design an electron collimation system for Elekta Infinity accelerators with significantly reduced applicator weights, while maintaining acceptable in-field beam flatness and out-of-field leakage dose. The design was restricted to 6-20 MeV beams for 6x6 to 25x25 …

    lsu-thes Repository record for Design and Validation of a Prototype Collimation System with Reduced Applicator Weights for Elekta Electron Therapy Beams (opens in a new tab)

  6. Development of metal-based (radio)pharmaceuticals for imaging and therapy

    … of the most promising radionuclides for Auger electron therapy; however, few studies exploring separation and radiolabeling of radioantimony exist in the literature. Bombardment of natSn with 12.8 MeV protons achieved production of primarily ¹²⁰mSb, as well as ¹¹⁷mSn. These species were then …

    ubc Repository record for Development of metal-based (radio)pharmaceuticals for imaging and therapy (opens in a new tab) Download PDF for Development of metal-based (radio)pharmaceuticals for imaging and therapy (opens in a new tab)

  7. Design, Fabrication, and Validation of 3D Printed, Patient-Specific Compensators For Postmastectomy Radiation Therapy

    … limitations for postmastectomy radiation therapy (PMRT). Tissue compensators can be used to reduce dose heterogeneity, hot and cold spots at field junctions, and treatment complexity, but are currently seldom used due to the difficulty in designing, fabricating, and validating them. To …

    uthsc Repository record for Design, Fabrication, and Validation of 3D Printed, Patient-Specific Compensators For Postmastectomy Radiation Therapy (opens in a new tab)

  8. Intensity Modulated Bolus Electron Conformal Therapy (IM-BECT): Methods for Quality Assurance of PRIME Intensity Modulators and Evaluation of Planned IM-BECT Dose Distributions

    Purpose: Intensity-modulated bolus electron conformal therapy (IM-BECT) shapes homogeneous dose distributions to superficial, irregularly-shaped target volumes, avoiding nearby critical structures. This dissertation provides research useful for translating IM-BECT to the radiotherapy clinic by: (1) …

    lsu-thes Repository record for Intensity Modulated Bolus Electron Conformal Therapy (IM-BECT): Methods for Quality Assurance of PRIME Intensity Modulators and Evaluation of Planned IM-BECT Dose Distributions (opens in a new tab)