Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 221 for “"electroosmotic"”.

  1. Electroosmotic Soft Actuators

    … applied to the fluid, across the microchannels, electroosmotic flow occurs in the direction of the applied electric field. In this work, liquid was electroosmotically displaced within a flexible microfluidic device to actuate an elastomeric membrane. The goal of this work was to create a fully …

    maryland Repository record for Electroosmotic Soft Actuators (opens in a new tab)

  2. Microparticle Influenced Electroosmotic Flow

    The influence of microparticles on electroosmotic flow was investigated experimentally and numerically. Experiments were conducted using four different particle types of varying chemical composition, surface charge and polarity. Each particle type was tested at five different volume fractions …

    byu Repository record for Microparticle Influenced Electroosmotic Flow (opens in a new tab) Download PDF for Microparticle Influenced Electroosmotic Flow (opens in a new tab)

  3. PED: pressurized electroosmotic dewatering

    … and an induced hydraulic gradient opposing the electroosmotic gradient is not established as soon.;The experimental program investigated the optimization of pressurized electroosmotic dewatering (PED) of ultra-fine coal suspensions. The slurry characteristics of greatest interest were the …

    iastate Repository record for PED: pressurized electroosmotic dewatering (opens in a new tab)

  4. Bubble Free Electrodes for Electroosmotic Pumping

    <p>Electroosmotic (EO) pumping is a widely used micro fluidic pumping technique due to its advantages such as simple design, applicability to wide range of conductive fluids and favorable scaling of electrical forces. Electrodes are necessary to establish the electrical forces and hence fluid flow …

    mcmaster Repository record for Bubble Free Electrodes for Electroosmotic Pumping (opens in a new tab)

  5. Studies of Electroosmotic Flow Dynamics During Electrophoretic Separations

    <p>Instrumentation and techniques for monitoring electroosmotic flow (EOF) during capillary electrophoretic (CE) separations in both fused-silica capillaries and glass microfluidic devices are presented. These techniques were applied under conventional and sample stacking separation conditions. The …

    utk-theses Repository record for Studies of Electroosmotic Flow Dynamics During Electrophoretic Separations (opens in a new tab)

  6. Electroosmotic Flow Characterization and Enhancement in PDMS Microchannels

    Electroosmotic flow is widely used as a solution pumping method in numerous microfluidic applications. This type of flow has several advantages over other pumping techniques, such as the fast response time, the ease of control and integration in different microchannel designs. The flow utilizes the …

    waterloo Repository record for Electroosmotic Flow Characterization and Enhancement in PDMS Microchannels (opens in a new tab)

  7. Studies of electroosmotic flow in non-aqueous capillary electrophoresis

    … of the effects of many experimental factors on electroosmotic flow (EOF) in non-aqueous capillary electrophoresis (CE) was performed. The effects of applied voltage, organic solvents and organic salts as running buffer components, and various rinsing protocols are presented and discussed. The …

    ut-knoxville Repository record for Studies of electroosmotic flow in non-aqueous capillary electrophoresis (opens in a new tab)

  8. Proposed laboratory investigation into electroosmotic dewatering of mine tailings

    … strength gain in surficial mine tailings using electroosmotic dewatering (EOD) to help promote closure and reclamation of TSFs. Electroosmotic dewatering uses electrodes to apply an electrical direct current to induce flow through a porous medium. An experiment was developed to assess the …

    colostate Repository record for Proposed laboratory investigation into electroosmotic dewatering of mine tailings (opens in a new tab)

  9. Design and fabrication of a new 3D AC-electroosmotic micropump

    … this thesis a new design for the AC electroosmotic is introduced. The new AC electroosmotic design presents the transition from planar microelectrode arrays to planar with High Aspect Ratio (HAR) pillars in order to increase the surface area of the electrodes. The physical mechanism …

    soton Download PDF for Design and fabrication of a new 3D AC-electroosmotic micropump (opens in a new tab)

  10. Alternating Current Electroosmotic Micropumping Using A Square Spiral Microelectrode Array

    An alternating current electroosmotic micro pumping device has been designed, experimentally tested and theoretically analyzed using an electrohydrodynamic theoretical model applied to a computer simulation model. The device SP-1 is a microelectrode array which uses the principal of AC …

    queens Repository record for Alternating Current Electroosmotic Micropumping Using A Square Spiral Microelectrode Array (opens in a new tab)

  11. Numerical Simulation of Electroosmotic Flow of Viscoelastic Fluid in Microchannel

    Electroosmotic flow (EOF) has been widely used in various biochemical microfluidic applications, many of which often involve the use of viscoelastic non-Newtonian fluids. Due to the existence of the elastic effect, the viscoelastic EOF develops into chaotic flow under extremely low Reynolds …

    odu Repository record for Numerical Simulation of Electroosmotic Flow of Viscoelastic Fluid in Microchannel (opens in a new tab)

  12. Investigation of electroosmotic flow dynamics and reproducibility in capillary electrophoresis

    The goal of this dissertation is to investigate electroosmotic flow (EOF) and electric field dynamics during capillary electrophoresis (CE) experiments using methods based on periodic photobleaching of fluorophores added to the separation buffer at nanomolar concentrations. The methods provide time …

    lsu-thes Repository record for Investigation of electroosmotic flow dynamics and reproducibility in capillary electrophoresis (opens in a new tab)

  13. Electroosmotic flow in the microchannels of the bone Haversian system

    Includes bibliographical references (pages 42-43).

    colo-mines Repository record for Electroosmotic flow in the microchannels of the bone Haversian system (opens in a new tab)

  14. Suppression of Capillary Electrophoresis Electroosmotic Flow with a Polymerized Phospholipid Coating

    … coating was characterized by measuring the electroosmotic flow using a previously reported method based on the profile of three injections of a neutral marker. Compared to an unmodified fused silica capillary which had an electroosmotic flow of 53.00 ± 0.01 ×10−5 cm2/Vs, the capillary …

    wvu Repository record for Suppression of Capillary Electrophoresis Electroosmotic Flow with a Polymerized Phospholipid Coating (opens in a new tab)

  15. An Analysis of Eliminating Electroosmotic Flow in a Microfluidic PDMS Chip

    The goal of this project is to eliminate electroosmotic flow (EOF) in a microfluidic chip. EOF is a naturally occurring phenomenon at the fluid-surface interface in microfluidic chips when an electric field is applied across the fluid. When isoelectric focusing (IEF) is carried out to separate …

    calpoly Repository record for An Analysis of Eliminating Electroosmotic Flow in a Microfluidic PDMS Chip (opens in a new tab)

  16. Dehumidification Effect by Coupling an Electroosmotic Material With a Desiccant Interface

    An electroosmotic dehumidifier system is modeled in order to estimate the area (size), voltage and power needed per unit mass flow of water to be transferred from a region. The operation of an A/C system with and without the electroosmotic dehumidifier is compared and situations where savings is …

    uiuc Repository record for Dehumidification Effect by Coupling an Electroosmotic Material With a Desiccant Interface (opens in a new tab)

Page 1 of 12