Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 54 for “"electroosmotic flow (EOF)"”

  1. POLYMER NANOPARTICLES IN ELECTROKINETIC CHROMATOGRAPHY

    … hundred volts per cm on the capillary induces electroosmotic flow (EOF) of the BGE and mobility of the PSP. Various ionic PSPs are capable of fast, selective, and efficient analytical separations.

    montana-tech Repository record for POLYMER NANOPARTICLES IN ELECTROKINETIC CHROMATOGRAPHY (opens in a new tab)

  2. POLYMER NANOPARTICLES IN ELECTROKINETIC CHROMATOGRAPHY

    … hundred volts per cm on the capillary induces electroosmotic flow (EOF) of the BGE and mobility of the PSP. Various ionic PSPs are capable of fast, selective, and efficient analytical separations.

    montana Repository record for POLYMER NANOPARTICLES IN ELECTROKINETIC CHROMATOGRAPHY (opens in a new tab)

  3. Photodefinable and Conductive Polydimethylsiloxane (PDMS) for Low-Cost Prototyping of Microfluidic Systems

    … of the conductive <i>photoPDMS</i>, an electroosmotic flow (EOF) device was designed and tested. This EOF device was fabricated entirely in <i>photoPDMS</i> materials and provides an excellent illustration of the promising advantages of the <i>photoPDMS</i> process for microfluidic …

    ohiolink Repository record for Photodefinable and Conductive Polydimethylsiloxane (PDMS) for Low-Cost Prototyping of Microfluidic Systems (opens in a new tab)

  4. Preparative-scale isoelectric trapping separations in a multicompartmental electrolyzer: implementation and monitoring

    … system, (2) the configuration of the liquid flow path, and (3) the cooling system. The second aspect (analytical-scale) is the monitoring of the IET separation: the design and manufacture of durable surface-modified capillaries which provide controlled, variable anodic and cathodic …

    tamu Repository record for Preparative-scale isoelectric trapping separations in a multicompartmental electrolyzer: implementation and monitoring (opens in a new tab)

  5. Capillary Isoelectric Focusing of Proteins with Carrier Ampholyte pH Gradient and Immobilized pH Gradient

    … coating methods were studied to reduce the electroosmotic flow (EOF) and proteins interactions with capillary inner surface. It could be concluded that, Glycidoxypropyltrimethoxysilane-hydroxypropyl cellulose (HPC) coated capillary column worked better with pressure mobilization while …

    okstate Repository record for Capillary Isoelectric Focusing of Proteins with Carrier Ampholyte pH Gradient and Immobilized pH Gradient (opens in a new tab)

  6. Studies of electroosmotic flow in non-aqueous capillary electrophoresis

    … of the effects of many experimental factors on electroosmotic flow (EOF) in non-aqueous capillary electrophoresis (CE) was performed. The effects of applied voltage, organic solvents and organic salts as running buffer components, and various rinsing protocols are presented and discussed. The …

    ut-knoxville Repository record for Studies of electroosmotic flow in non-aqueous capillary electrophoresis (opens in a new tab)

  7. Core-based hyperbranched polyethyleneimine coating in capillary electrophoresis

    … fused silica surface can be used to control the electroosmotic flow (EOF), to minimize the interaction of analytes with the capillary surface and to modify the selectivity. , core-based hyperbranched polyethyleneimine (CHPEI) polymer utilized as either a static or dynamic coating in this study. A …

    missouri Repository record for Core-based hyperbranched polyethyleneimine coating in capillary electrophoresis (opens in a new tab)

  8. An Analysis of Eliminating Electroosmotic Flow in a Microfluidic PDMS Chip

    The goal of this project is to eliminate electroosmotic flow (EOF) in a microfluidic chip. EOF is a naturally occurring phenomenon at the fluid-surface interface in microfluidic chips when an electric field is applied across the fluid. When isoelectric focusing (IEF) is carried out to separate …

    calpoly Repository record for An Analysis of Eliminating Electroosmotic Flow in a Microfluidic PDMS Chip (opens in a new tab)

  9. Separation of ions in acidic solution by capillary electrophoresis

    … salt to the electrolyte solution to reverse the electroosmotic flow (EOF). It is now shown that excellent separations of inorganic anions such as the anionic chloro complexes of the platinum group elements (PGEs) and anionic metal oxides are obtained using an acidic aqueous electrolyte carrier. …

    iastate Repository record for Separation of ions in acidic solution by capillary electrophoresis (opens in a new tab)

  10. Development of Polymer-Based In-Plane Nanopore for DNA Sequencing

    … dTMP. At pH 10.0, mononucleotides were driven by electroosmotic flow (EOF) due to a higher surface charge density on nanochannel walls and ToF was in the same order as pH 8.0 with an average identification accuracy of 55%. Dual-nanopore device with 1 μm flight tube was then used to improve the …

    lsu-thes Repository record for Development of Polymer-Based In-Plane Nanopore for DNA Sequencing (opens in a new tab)

  11. Microfluidic Electro-osmotic Flow Pumps

    … previously developed thin film technologies, an electroosmotic flow (EOF) pump was incorporated in a microfluidic liquid chromatography device. An EOF pump was chosen because of its simple design and small size. EOF pumps fabricated on silicon and glass substrates were evaluated. The experimental …

    byu Repository record for Microfluidic Electro-osmotic Flow Pumps (opens in a new tab)

  12. Capillary electrophoresis in the analysis and characterisation of lubricant additives.

    … was shown to be essential in controlling the electroosmotic flow (EOF), and its concentration was optimised. Best separation was seen when analyte dilution prior to injection was carried out with methanol, resulting in sample stacking.Analysis of ZDDPs showed that separation occurred through …

    sheffield-hallam Repository record for Capillary electrophoresis in the analysis and characterisation of lubricant additives. (opens in a new tab)

  13. Electroosmotic flow driven free antigens reaction with immobilized magnetic-microbeads-tagged-antibodies in microchannel

    … between mMB-Ab and Ag in the presence of electroosmotic flow (EOF). First, mMB-Ab complex was immobilized in the wall of the capture zone. Subsequently, the Ag was transported by EOF towards the capture zone to bind with the immobilized mMB-Ab. Lastly, mMB-Ab:Ag complex was formed and …

    ohiolink Repository record for Electroosmotic flow driven free antigens reaction with immobilized magnetic-microbeads-tagged-antibodies in microchannel (opens in a new tab)

  14. Development of a microfluidic system as basis for electrochromatography

    … is a separation technique, where the liquid flow is generated by an electric field. The main advantage of using an electric field instead of pressure to generate the flow is the flat profile of the electroosmotic flow (EOF). CEC is one of the best candidates to construct a novel, high …

    epfl Repository record for Development of a microfluidic system as basis for electrochromatography (opens in a new tab)

  15. Development of Gate-Controlled DC Electrokinetic Micropumps

    … progress has been accomplished; however, fluid flow control still needs improvement and reminds one of the significant challenges for the future practical LOC devices. This thesis explores the application of electroosmosis (EO) technique and field effect flow control (FEFC) technology for …

    ut-knoxville Repository record for Development of Gate-Controlled DC Electrokinetic Micropumps (opens in a new tab)

  16. Applications of electrochemiluminescence detection on microfabricated devices

    … ECL detection of guanosine. The magnitude of electroosmotic flow (EOF) in PDMS microchannels was determined using the current monitoring method. Results revealed that the origin of the surface charge in PDMS is the same as in silica, but its amount is considerably lower.

    aalto Repository record for Applications of electrochemiluminescence detection on microfabricated devices (opens in a new tab)

  17. Design and applications of an improved capillary electrophoresis - electrospray ionization - mass spectrometry interface

    … interface strategy. The new interface uses a flow-through microvial design and a bevelled sprayer tip geometry. The capillary column terminus is surrounded by a tapered stainless steel hollow needle, and the interior of the needle tip acts as the CE outlet while its exterior tip surface …

    ubc Repository record for Design and applications of an improved capillary electrophoresis - electrospray ionization - mass spectrometry interface (opens in a new tab)

  18. Numerical Simulation of Viscoelastic Flow in Micro/Nanochannels

    … to 3D, stationary to transient problems. Then, flow behavior of viscoelastic fluid in a three-dimensional curvy channel is investigated. A Finitely Extensible Nonlinear Elastic with Peterlin closure (FENE-P) constitutive model is utilized to describe the viscoelastic fluid. The characterization …

    odu Repository record for Numerical Simulation of Viscoelastic Flow in Micro/Nanochannels (opens in a new tab)

  19. Analytical separations using packed and open-tubular capillary electrochromatography

    … relative standard deviation (RSD) values of the electroosmotic flow (EOF). The PEM-coated capillaries were remarkably robust with excellent reproducibilities and high stabilities against extreme pH values. The stability of the capillary surface was further investigated after exposure to NaOH …

    lsu-thes Repository record for Analytical separations using packed and open-tubular capillary electrochromatography (opens in a new tab)

Page 1 of 3