Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 60 for “"energy analyzer"”.

  1. Ion temperature measurements in STOR-M boundary plasmas using a retarding field energy analyzer

    The Retarding Field Energy Analyzer (RFEA, RFA) is a simple and reliable diagnostic technique to measure the ion temperature in the Scrape-Off Layer (SOL) and edge of magnetic fusion devices. Design and operation features of a single-sided (facing the ion down stream side) RFEA for ion temperature …

    sask Repository record for Ion temperature measurements in STOR-M boundary plasmas using a retarding field energy analyzer (opens in a new tab)

  2. Development of a Gridded Energy Analyzer for Measurement of the Mochi Experiment Ion Energy Distribution

    … thesis describes the development of a gridded energy analyzer (GEA), the ultimate goal of which is to provide initial measurements of Mochi’s ion energy distribution. The concept of the Mochi.GEA is to start with the simplest possible design and make necessary improvements based on observed …

    washington Repository record for Development of a Gridded Energy Analyzer for Measurement of the Mochi Experiment Ion Energy Distribution (opens in a new tab)

  3. Design and Simulation of a Miniature Cylindrical Mirror Auger Electron Energy Analyzer with Secondary Electron Noise Suppression

    … and simulate a miniature Cylindrical Mirror Analyzer, (CMA), and Auger Electron Spectrometer, (AES). The CMA includes an integrated coaxial thermionic electron source. Electron optics simulations were performed using the Finite Element Method, (FEM), software COMSOL. To address the large …

    usf Repository record for Design and Simulation of a Miniature Cylindrical Mirror Auger Electron Energy Analyzer with Secondary Electron Noise Suppression (opens in a new tab)

  4. Measurement of plasma parameters in the exhaust of a magnetoplasma rocket by gridded energy analyzer and emissive Langmuir probe

    … tens of kilometers per second. In this device, energy is imparted to the plasma ions by two mechanisms: ion cyclotron resonant heating (ICRH), and acceleration in an ambipolar electric field. Measurements from two different electrostatic probes are combined to determine how much each mechanism …

    rice Repository record for Measurement of plasma parameters in the exhaust of a magnetoplasma rocket by gridded energy analyzer and emissive Langmuir probe (opens in a new tab)

  5. Determination of Ionization Fraction and Plasma Potential in a DC Magnetron Sputtering System Using a Quartz Crystal Microbalance and a Gridded Energy Analyzer

    Made available in DSpace on 2017-07-06T18:48:17Z (GMT). No. of bitstreams: 3 Green_Karyn_M_MS.pdf: 35887684 bytes, checksum: 4d8ec8bef5ab4e9e6aabee4e3ff410a5 (MD5) Green_Karyn_M_MS_ABS.pdf: 507343 bytes, checksum: 0d504c63e61c048bbb16c0ee4bce83fa (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Determination of Ionization Fraction and Plasma Potential in a DC Magnetron Sputtering System Using a Quartz Crystal Microbalance and a Gridded Energy Analyzer (opens in a new tab)

  6. Quantitive determination of the fraction of Rydberg electrons in a convoy electron cusp

    <p>Convoy electron energy spectra were measured using an electrostatic electron energy analyzer and CEM detector. Recently it was suggested that the origin of a significant fraction of the measured convoy electron yields is due to field ionization of high Rydberg states inside the electron energy …

    ut-knoxville Repository record for Quantitive determination of the fraction of Rydberg electrons in a convoy electron cusp (opens in a new tab)

  7. EXPERIMENTAL STUDY OF LONGITUDINAL ENERGY SPREAD IN SPACE-CHARGE- DOMINATED BEAMS

    … variable-focusing retarding field energy analyzer has been developed to measure the energy spread of space-charge-dominated electron beams. A cylindrical focusing electrode is used to overcome the beam expansion inside the device due to space-charge forces, beam emittance, etc. The …

    maryland Repository record for EXPERIMENTAL STUDY OF LONGITUDINAL ENERGY SPREAD IN SPACE-CHARGE- DOMINATED BEAMS (opens in a new tab)

  8. A Neutral Beam Probe for the Helimak plasma experiment

    … the resulting ion beam followed a path to an energy analyzer where the change of energy was detected along with the total ion current. The measurement of the change of energy implies a change of potential energy at the point of ionization since all the neutral beam particles enter the plasma …

    texas Repository record for A Neutral Beam Probe for the Helimak plasma experiment (opens in a new tab)

  9. Energy Efficiency Analysis and Implementation of AES on an FPGA

    … varying throughput, area, power dissipation and energy consumption requirements. Field Programmable Gate Arrays (FPGAs) are flexible and reconfigurable integrated circuits that are useful for many different applications including the implementation of AES. Though they are highly flexible, FPGAs …

    waterloo Repository record for Energy Efficiency Analysis and Implementation of AES on an FPGA (opens in a new tab)

  10. Ultra-Low Emittance Iii-V Semiconductor Photocathodes

    … (km scale) electron accelerators (used for high energy physics experiments and as x-ray sources) as well as small (m scale) ultra-fast electron diffraction setups is limited by the source of electrons. Low energy (< 1 eV) electrons obtained using visible light from III-V semiconductors activated …

    cornell Repository record for Ultra-Low Emittance Iii-V Semiconductor Photocathodes (opens in a new tab)

  11. Design and testing of compact Mott polarimeters for use in energy- and angle-resolved polarization measurements

    … incorporates an in-line retarding potential energy analyzer with an energy resolution $\sim$0.5eV, and is suitable for a wide variety of applications requiring energy- and angle-resolved polarization measurements.

    rice Repository record for Design and testing of compact Mott polarimeters for use in energy- and angle-resolved polarization measurements (opens in a new tab)

  12. Design and calibration of the Suprathermal Ion Detector Experiment (SIDE)

    … Package (ALSEP). It is designed to measure mass, energy per unit charge, and flux of positive ions at the surface of the moon. The SIDE contains two analyzers. One is for low energy ions; it consists of E X B velocity analyzer and a cylindrical curved plate energy analyzer aligned with a …

    rice Repository record for Design and calibration of the Suprathermal Ion Detector Experiment (SIDE) (opens in a new tab)

  13. A Retarding-potential Analyzer for Measuring Energy Distributions in Electron Beams

    An energy analyzer for electron beams, based on a retarding-potential method, has been studied both experimentally and theoretically. In this method a potential energy barrier at right-angles to the beam acts as a high-pass energy filter allowing electrons having energies greater than the barrier …

    portland-state Repository record for A Retarding-potential Analyzer for Measuring Energy Distributions in Electron Beams (opens in a new tab)

  14. STUDY OF SPACE-CHARGE WAVES IN A LONG SOLENOID CHANNEL

    … are presented. Then experimental studies on the energy modulations converted from density modulations are reported. By changing the working conditions of the electron gun, pure initial density modulations are generated. Energy perturbation waveforms are measured by a high resolution energy …

    maryland Repository record for STUDY OF SPACE-CHARGE WAVES IN A LONG SOLENOID CHANNEL (opens in a new tab)

  15. Designing and Commissioning of a Prototype High Energy Resolution Fluorescence Detection System at the Canadian Light Source

    … as a feasibility study into running a High Energy Resolution Fluorescence Detection system for x-ray absorption spectroscopy at the Hard X-ray MicroAnalysis beamline at the Canadian Light Source. This study was carried out through the construction of an x-ray photon energy analyzer system …

    guelph Repository record for Designing and Commissioning of a Prototype High Energy Resolution Fluorescence Detection System at the Canadian Light Source (opens in a new tab)

  16. Analysis of low-energy neutral hydrogen fluxes using an electron cyclotron resonance-heated discharge

    … with subsequent detection in a high resolution energy analyzer. A versatile calibration technique is applied to determine the ionizer efficiency, which additionally gives a variety of elastic scattering and charge exchange cross section results. Also described are the details of a new low energy …

    uiuc Repository record for Analysis of low-energy neutral hydrogen fluxes using an electron cyclotron resonance-heated discharge (opens in a new tab)

  17. Energetic Deposition of Niobium Thin Film in Vacuum

    … system has been developed to study deposition energy effects on the properties of niobium thin films on various substrates. The system directly uses microwave power to create a pure niobium plasma, which can be used to extract niobium ion flux with controllable kinetic energy for direct …

    vt Repository record for Energetic Deposition of Niobium Thin Film in Vacuum (opens in a new tab)

  18. Surface studies using spin-polarized electron energy loss spectroscopy

    Spin-polarized electron energy loss spectroscopy (SPEELS) has been used to investigate several paramagnetic surfaces. In this technique, a low energy beam of spin-polarized electrons from a GaAs source is directed at the surface to be studied and the spin-polarization of the emitted electrons, as …

    rice Repository record for Surface studies using spin-polarized electron energy loss spectroscopy (opens in a new tab)

  19. Electrical and thermal diagnostics for a better understanding of the energy balance of species in technological plasmas

    … thesis explores the investigation of the energy balance of species in technological plasmas through the application of electrical and thermal diagnostics. The research focuses on advancing the understanding of the energy balance of species in plasmas by employing electrical, thermal, and …

    cau-kiel Repository record for Electrical and thermal diagnostics for a better understanding of the energy balance of species in technological plasmas (opens in a new tab)

Page 1 of 3