Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"energy resolving"”.
-
Resonant soft X-ray studies of charge orders in high-temperature cuprates with energy-resolving transition edge sensors
… of charge orders by tuning the incident photon energy close to absorption edge of target element, for example Cu in cuprates; however, the inelastic fluorescence (usually referred as background in RSXS experiments) is also the most intense at resonance making short-ranged charge orders harder to …
-
Neutron strain tomography
… strains within the sample. If a two-dimensional energy-resolving pixellated detector is used to record the transmission strains, a spatially resolved two-dimensional image of the average strain within the sample is obtained. This implies that if one records two-dimensional average strain data …
-
Advances in Energy Sensitive X-ray Phase Contrast Measurements
… the development and test of the firsttable-top energy resolving X-ray refractometer. Energy dependent index decrement, δ, values are extracted for several materials over a range of energy values. The experimental apparatus uses a Micro X-ray Inc. microfocus source with a focal spot size of …
-
Single photon counting x-ray diffraction techniques for the investigation of shock compressed condensed matter
… use of a single photon counting CCD to measure energy resolved diffraction signal. Using CCDs in this way has not been done before in a high power laser experiment. The first diagnostic measures diffraction from a poly-crystalline sample and along with experimental results, a simulation code was …
-
Novel experimental and computational methods for ultrafast time-resolved coherent diffraction imaging
… model systems throughout this thesis. A photon-energy scan across the helium 1s^2 to the 1s2p resonance demonstrates how resonant scattering modifies diffraction contrast and highlights both the opportunities and limitations of exploiting energy-dependent optical responses for imaging. Building …
-
Dual Energy Contrast Enhanced Mammography Using a Photon Counting Spectral Detector
… creation of X-ray photon counting detectors with energy-resolving capabilities. The additional spectral information captured by these detectors has spurred development of more advanced material identification methods. One such method is dual-energy contrast-enhanced mammography, which is an …
-
Superconducting Nanostructures for Quantum Detection of Electromagnetic Radiation
… irradiation. Based on this finding, we propose an energy-resolving terahertz radiation detector using superconducting nanowires. In superconducting nanostrips, topological fluctuations are the magnetic vortices. The motion of magnetic vortices result in dissipative processes that limit the …
-
Spectroscopy of core-excited molecules and exploration of the induced dynamics
… a reflectron mass spectrometer,hemispherical energy resolving electron analysers, and 3D momentum imaging spectrometers for charged particles.Results: X-ray absorption like spectra were obtained for new ions, CH+3 ,CH+4 , and CH+5 . The ionised versionsof CHn revealed a much clearer picture of …
-
INVESTIGATION OF CADMIUM ZINC TELLURIDE DETECTOR FOR MEDICAL IMAGING APPLICATIONS
… A number of properties, including superior energy resolution, 3D photon position sensitivity, compact size, direct photon conversion and energy-resolving capability, make CZT a promising candidate for positron emission tomography (PET) and photon-counting X-ray imaging systems. Despite these …
-
Spectral Signature and Correction of Scattered Radiation in Energy-Resolved X-ray Imaging
… possible photon counting detectors (PCDs) with energy-resolving capabilities. Exploiting spectral information of the incident radiation promises revolutionary approaches to material identification and characterization. However, radiation that scatters from the object and reaches the detector is …
-
Reducing Radiation Dose to the Female Breast During Conventional and Dedicated Breast Computed Tomography
… and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing breast dose, during energy-resolved dedicated breast CT. A database quantifying organ dose for several radiosensitive organs irradiated during CTCA, …
-
Pixel Detectors
… pixel detectors are presented. The first is an energy resolving detector (ERD1) which has been characterised using laboratory sources and the synchrotron radiation source (SRS) at Daresbury. The ERD1 is a 16 by 16 array of 300 mum by 300 mum square pixels, the detector is 300 mum thick Si and is …
-
Attosecond Electron Spectroscopy
… streaking technique, which consists in energy-resolving photoelectrons ejected by an attosecond extreme ultraviolet pulse, in the presence of a phase-stabilized and temporally synchronized near-infrared field. Although it was originally devised as a means to characterize attosecond …
-
An Investigation of Target Poisoning during Reactive Magnetron Sputtering
… uxes towards and from the target by means of energy resolved mass spectrometry. For experiments a planar, circular DC magnetron, equipped with a 2 inch titanium target was installed in an ultrahigh vacuum chamber which was attached to the beam line system of a 5 MV tandem accelerator. A …