Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"envelope signal"”.

  1. Robust bone detection in ultrasound using combined strain imaging and envelope signal power detection

    … by combining ultrasound strain imaging and envelope power detection methods. After an estimation of the strain and envelope power maps, we subsequently fused these maps into a single combined map that corresponds robustly to the actual bone boundaries. This study has achieved a marked …

    ubc Repository record for Robust bone detection in ultrasound using combined strain imaging and envelope signal power detection (opens in a new tab) Download PDF for Robust bone detection in ultrasound using combined strain imaging and envelope signal power detection (opens in a new tab)

  2. Analysis and Design of Envelope Tracking Power Amplifier

    … communication systems, complex non-constant envelope modulation signals with high peak to average ratio (PAPR) have been emerged. Hence, conventional power amplifiers must be operated in back-off to meet the stringent linearity requirements, resulting in a substantial efficiency degradation. …

    poli-torino Repository record for Analysis and Design of Envelope Tracking Power Amplifier (opens in a new tab)

  3. A neural network TensorFlow framework for power amplifier distortion analysis and mitigation.

    … distortion through post-compensating the output signal or pre-distorting the input signal. Despite its simple structure and the lightweight computation, the ANN model provides ~12 dB of ACPR improvement (at 25 dBm average output power) through output post-compensation, as well as ~6 dB of ACPR …

    baylor Repository record for A neural network TensorFlow framework for power amplifier distortion analysis and mitigation. (opens in a new tab)

  4. Improved Techniques for Statistical Analysis of the Envelope of Backscattered Ultrasound Using the Homodyned K Distribution

    … were developed and assessed based on the envelope of backscattered ultrasound. The envelope of backscattered ultrasound can be modeled as the superposition of the scattered signals from individual scatterers in the medium being interrogated. As such, the envelope signal is statistical in …

    uiuc Repository record for Improved Techniques for Statistical Analysis of the Envelope of Backscattered Ultrasound Using the Homodyned K Distribution (opens in a new tab)

  5. High-Density Electromyography Biomarkers for Detecting and Monitoring of Muscle Spasticity During Passive Stretch Assessment

    … detection and monitoring biomarker. The envelope root mean squared (RMS) signal was calculated to see the change in the muscle amplitude during fast passive extension (FPE) and slow passive extension (SPE) of the spastic biceps brachii muscle. Further features extracted from the RMS …

    houston Repository record for High-Density Electromyography Biomarkers for Detecting and Monitoring of Muscle Spasticity During Passive Stretch Assessment (opens in a new tab)

  6. Design and Implementation of a Constant Envelope OFDM Waveform in a Software-Defined Radio Platform

    … to the PAPR-problem in the form of a constant-envelope OFDM (CE-OFDM) waveform, a waveform which employs phase modulation to transform the high-PAPR OFDM signal into a constant envelope signal, like FSK or GMSK, which can be amplified with non-linear power amplifiers at near saturation levels …

    vt Repository record for Design and Implementation of a Constant Envelope OFDM Waveform in a Software-Defined Radio Platform (opens in a new tab)

  7. Frequency Locking Techniques Based on Envelope Detection for Injection-Locked Signal Sources

    Signal generation at high frequency has become increasingly important in numerous wireline and wireless applications. In many gigahertz and millimeter-wave frequency ranges, conventional frequency generation techniques have encountered several design challenges in terms of frequency tuning range, …

    vt Repository record for Frequency Locking Techniques Based on Envelope Detection for Injection-Locked Signal Sources (opens in a new tab)

  8. Circularly-Shifted Chirps for Triple Functionality: Communications, Radar, and Computation

    … also leverages the fact that a CSC is a constant-envelope signal to achieve a controllable peak-to-mean envelope power ratio (PMEPR). For radar functionality, CSC-IM maintains the good autocorrelation (AC) properties of a chirp by ensuring that the transmitted CSCs are separated apart sufficiently …

    south-carolina Repository record for Circularly-Shifted Chirps for Triple Functionality: Communications, Radar, and Computation (opens in a new tab)

  9. Analysis and design of ΣΔ Modulators for Radio Frequency Switchmode Power Amplifiers

    … is needed for transmitting WCDMA and OFDM signals, linear operation of a power amplifier is characterized by low power efficiency, and contributes to unwanted power dissipation in a transmitter. Recently, a switchmode power amplifier operation was considered for reducing power losses in a …

    maynooth Download PDF for Analysis and design of ΣΔ Modulators for Radio Frequency Switchmode Power Amplifiers (opens in a new tab)

  10. LINT MODULATOR

    … The problem is that the non-constant envelope of linear modulation schemes requires linear amplification. Linear amplification can be obtained with a Class A amplifier solution, which suffers from very low power efficiency. Poor power efficiency is not suitable for highly integrated or …

    sask Repository record for LINT MODULATOR (opens in a new tab)

  11. Transient simulation of complex electronic circuits and systems operating at ultra high frequencies

    … interconnect effects are a major cause of the signal degradation encountered b y a signal propagating through linear interconnect networks in the modem IC. Therefore, the development of an interconnect model that can accurately and efficiently take into account frequency-dependent parameters of …

    dcu Download PDF for Transient simulation of complex electronic circuits and systems operating at ultra high frequencies (opens in a new tab)

  12. Digital modulators with crest factor reduction techniques

    … second-generation (2G) system that uses constant envelope Gaussian minimum shift keying modulation. The advantage achieved by constant envelope modulation is the possibility of using power-efficient power amplifiers (PAs). However, it might be beneficial to combine the carriers in a digital …

    aalto Repository record for Digital modulators with crest factor reduction techniques (opens in a new tab)

  13. Investigation of hybrid digital/analog pre-distortion of GaN power amplifier

    … networking and standard Wi-Fi. In an OFDM signal, the envelope signal is non-constant and it typically has a rise peak-to-average power ratio (PAPR), making it highly susceptible to distortion induced by nonlinear inline component response in transmission systems. Power is a concern in …

    ets-quebec Download PDF for Investigation of hybrid digital/analog pre-distortion of GaN power amplifier (opens in a new tab)

  14. Design and Software Validation of Coded Communication Schemes using Multidimensional Signal Sets without Constellation Expansion Penalty in Band-Limited Gaussian and Fading Channels

    … that the use of multidimensional constellation signals can help to reduce the bit error rate in Additive Gaussian channels by using the hyperspace geometry more efficiently. Similarly, in fading channels, dimensionality provides an inherent signal space diversity (distinct components between two …

    uno Repository record for Design and Software Validation of Coded Communication Schemes using Multidimensional Signal Sets without Constellation Expansion Penalty in Band-Limited Gaussian and Fading Channels (opens in a new tab)

  15. Detektor QRS komplexu

    Cílem bakalářské práce s názvem Detektor QRS komplexu je seznámení se se základními principy detekce založené na umocnění a na obálce filtrovaného signálu. V první části této práce je popsán vznik elektrické aktivity srdce a způsoby jejího snímání. Dále jsou v práci popsány vlastnosti a typická …

    brno-tech Repository record for Detektor QRS komplexu (opens in a new tab)

  16. Detektor QRS komplexu

    Cílem této práce je seznámení s problematikou detekce QRS komplexu na základě umocnění a obálky filtrovaného signálu. První část práce je zaměřena na vznik a snímání elektrické srdeční aktivity. Následně jsou v textu popsány nejčastější typy rušení EKG signálu a principy jejich filtrace. Druhá část …

    brno-tech Repository record for Detektor QRS komplexu (opens in a new tab)

  17. Combined Linearization of both Analog and Digital Pre-Distortion for Broadband Radio over Fiber Transmission

    … (OFDM) technique is introduced. As an OFDM signal is a non-constant envelope signal and usually has a high peak-to-average power ratio (PAPR), it is very sensitive to the distortion caused by the nonlinear response of inline components in transmission systems. Within a system, the …

    concordia Download PDF for Combined Linearization of both Analog and Digital Pre-Distortion for Broadband Radio over Fiber Transmission (opens in a new tab)

  18. Detekce QRS komplexu z klidového a zátěžového EKG

    Tato bakalářská práce se zabývá způsoby detekce QRS komplexu v EKG signálu. Je zde zobrazena elektrická aktivita srdce a samotný signál EKG. Jsou zde vylíčeny některé metody způsobu detekce a podrobněji je popsána realizace v matlabu dvou z nich. Nechybí zde ani hodnocení úspěšnosti obou …

    brno-tech Repository record for Detekce QRS komplexu z klidového a zátěžového EKG (opens in a new tab)