Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 319 for “"evaporative cooling"”.

  1. Evaporative cooling on a grooved surface

    Spray evaporative cooling defines a mode of heat transfer where the drops evaporate on contact with the heated surface. Since no water accumulates on the surface, the term "dry wall" is used to described the surface condition. If while operating in the drywall mode the surface temperature is …

    rice Repository record for Evaporative cooling on a grooved surface (opens in a new tab)

  2. Evaporative cooling in the contact line region

    Evaporative cooling of small, high power dissipating devices using thin liquid films is becoming an increasingly important field of research as the requirements for this tech- nology grow. Understanding the mechanisms which cause liquid motion in the film and evaporation from the liquid surface is …

    ubc Repository record for Evaporative cooling in the contact line region (opens in a new tab) Download PDF for Evaporative cooling in the contact line region (opens in a new tab)

  3. A fundamental study of spray evaporative cooling

    "Spray evaporative cooling" is defined as the mode of spray cooling heat transfer for which no liquid film would form on a heated surface of infinite extent. The heat flux during this mode is simply that required to vaporize all of the impinging spray. The lower surface temperature range limit for …

    rice Repository record for A fundamental study of spray evaporative cooling (opens in a new tab)

  4. Fiber-based absorbent configuration in evaporative cooling

    … friendly methods are needed for use in cooling systems and related applications. In this study, a new cooling system model using absorbent fabric wrapping in curtain structure on scaffolding for short-term transportation and storage was built and a series of laboratory scale experiments …

    missouri Repository record for Fiber-based absorbent configuration in evaporative cooling (opens in a new tab)

  5. Evaporative Cooling in Electromagnetic Radio Frequency Traps

    … of these fields with multiple ions can cause, cooling the system could be of great interest, and there are several methods of doing so. This study explores on of these methods, evaporative cooling, applied to a type of Paul trap, a Linear Paul Trap (LPT), using computer simulations. This thesis …

    calgary Repository record for Evaporative Cooling in Electromagnetic Radio Frequency Traps (opens in a new tab)

  6. Fostering Evaporative Cooling with a Permeable Pavement Scaffold

    … Electrical power use is higher due to higher cooling costs. Air quality, mostly from tropospheric ozone, worsens under higher temperatures and UHI-created atmospheric conditions. Ultimately, higher average temperatures impact the health and wellbeing of people. While the UHI effect and climate …

    ut-knoxville Repository record for Fostering Evaporative Cooling with a Permeable Pavement Scaffold (opens in a new tab)

  7. Monitoring and Detecting Legionella within Evaporative Cooling Towers

    … particularly in Australia and New Zealand. Cooling towers are a predominant source of Legionnaires' outbreaks, as they support the growth of both sessile and planktonic microbial communities and facilitate their aerosolisation. Therefore, microbial growth within these structures must be …

    whiterose Download PDF for Monitoring and Detecting Legionella within Evaporative Cooling Towers (opens in a new tab)

  8. Fundamental design and study of an evaporative cooling system

    … study, the performance of a plate type indirect evaporative cooling system (IECS), based on cross-flow configuration, is numerically investigated. A two-dimensional model which considers variation of water film temperature and the wet channel wettability is developed to comprehensively describe …

    nus Repository record for Fundamental design and study of an evaporative cooling system (opens in a new tab) Download file for Fundamental design and study of an evaporative cooling system (opens in a new tab)

  9. Performance enhancement of heat exchanger coolers with evaporative cooling

    … for air-conditioning, refrigeration or process cooling applications in both commercial and industrial sector. However, air cooled heat exchanger performance degrades considerably with rise in ambient air temperature and water cooled coolers require considerable pumping power, a cooling tower and …

    maryland Repository record for Performance enhancement of heat exchanger coolers with evaporative cooling (opens in a new tab)

  10. The design evaluation of an improved indirect evaporative cooling system

    Energy efficient cooling systems are of particular interest in domestic and industrial applications today. The cost of energy has risen drastically in recent years and will probably continue to do so. To reduce cooling costs, conventional equipment must be made more efficient or new systems …

    ttu Repository record for The design evaluation of an improved indirect evaporative cooling system (opens in a new tab)

  11. Thermo-dynamical measurements for ATLAS Inner Detector (evaporative cooling system)

    … installation and initial operation of the Evaporative Cooling System for the ATLAS Inner Detector SCT Barrel Sub-detector, some performance characteristics were observed to be inconsistent with the original design specifications, therefore the assumptions made in the ATLAS Inner Detector …

    glasgow Download PDF for Thermo-dynamical measurements for ATLAS Inner Detector (evaporative cooling system) (opens in a new tab)

  12. Heat and Mass Transfer Characteristics of Indirect Evaporative Cooling System

    Indirect evaporative air coolers show good promise in extending the energy savings (compared with compression air conditioning system) from arid, low humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of …

    marquette Repository record for Heat and Mass Transfer Characteristics of Indirect Evaporative Cooling System (opens in a new tab)

  13. Effects of Evaporative Cooling in the Thermal Performance of Green Roofs

    … to green roofs is the reduction in heating and cooling loads in buildings by dissipating heat through evaporation. This study focuses on evaluating the effect that evaporative cooling has on the thermal performance of green roofs. Sponge and floral foam were used as porous media for their …

    portland-state Repository record for Effects of Evaporative Cooling in the Thermal Performance of Green Roofs (opens in a new tab)

  14. The mechanics of fiber-based absorbent evaporative cooling (fbaEC) for transport

    … methods are needed for use in cooling systems and related applications. In prior research, a new evaporative cooling system model using absorbent fabric wrapping in curtain structure on a scaffold for short-term transport and storage was built in a laboratory scale, and a series …

    missouri Repository record for The mechanics of fiber-based absorbent evaporative cooling (fbaEC) for transport (opens in a new tab)

Page 1 of 16