Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 22 for “"evaporative cooling system"”.
-
Fundamental design and study of an evaporative cooling system
… study, the performance of a plate type indirect evaporative cooling system (IECS), based on cross-flow configuration, is numerically investigated. A two-dimensional model which considers variation of water film temperature and the wet channel wettability is developed to comprehensively describe …
-
The design evaluation of an improved indirect evaporative cooling system
Energy efficient cooling systems are of particular interest in domestic and industrial applications today. The cost of energy has risen drastically in recent years and will probably continue to do so. To reduce cooling costs, conventional equipment must be made more efficient or new systems …
-
Thermo-dynamical measurements for ATLAS Inner Detector (evaporative cooling system)
… installation and initial operation of the Evaporative Cooling System for the ATLAS Inner Detector SCT Barrel Sub-detector, some performance characteristics were observed to be inconsistent with the original design specifications, therefore the assumptions made in the ATLAS Inner Detector …
-
Heat and Mass Transfer Characteristics of Indirect Evaporative Cooling System
Indirect evaporative air coolers show good promise in extending the energy savings (compared with compression air conditioning system) from arid, low humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of …
-
Augmenting traditional wind catcher with combined evaporative cooling system and solar chimney
Wind catchers are one of the oldest cooling systems in Hot-Dry regions that are employed to provide sufficient natural ventilation in buildings. The optimal adequacy of the wind catchers has been constrained in the suitable wind speed, which causes them to be inefficient at times and in areas with …
-
Analysis and feasibility of an evaporative cooling system with sessile droplet evaporation to provide cooling for microprocessors
The study investigates the cooling requirements for the Intel Xenon Processor and the Intel Core i7-900 Processor using diffusion based evaporation of sessile droplets. An analytical model is developed to determine the capacity of a single layer of droplets to provide sufficient cooling. It is …
-
The Effects of Exhaust Vent Location on Thermal Comfort Inside the Residential Buildings Equipped With an Evaporative Cooling System
… humidity is less than 8 %. In this regard, an evaporative cooling system is considered to increase humidity in the building since not only lack of humidity cause discomfort but also has many effects on breathing and skin dryness. A Computational Fluid Dynamic (CFD) study is developed as a …
-
Theoretical analysis of heat and mass transfer processes in an evaporative cooling system with zeolite desiccant powered by solar energy
[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI SYSTEM AT AUTHOR'S REQUEST.] Concerns about energy sources depletion and environmental pollution issues have been raised and is a top priority of the global community. Refrigeration machines have been received the major of attention because of their …
-
Development of a Thin-Film Evaporative Cooling System for a High Energy Thulium Holmium: Lutetium Lithium Flouride Solid-State Laser Oscillator Crystal
… parameters for the development of a thin-film evaporative cooling concept for a high energy, pulsed solid-state laser oscillator were investigated. The scope of the investigation was broad, and a multidisciplinary approach was employed. No contra-indicators for the feasibility of the proposed …
-
Αριθμητική προσομοίωση των συνθηκών περιβάλλοντος θερμοκηπίου με συστήματα φυσικού αερισμού και δροσισμού υγρής παρειάς
… area concerning natural ventilation and cooling conditions with pad and fan evaporative cooling system. Both the experimental procedures and the theoretical investigation were carried out at the facilities of the Center of Agricultural Structures Control located at the farm of Aristotle …
-
Analyze and Rebuild an Apparatus to Gauge Evaporative Cooling Effectiveness of Micro-Porous Barriers.
The sample used for evaporative cooling system is Fabric defender 750 with Shelltite finish. From the experimental data and equations we have diffusion coefficient of 20.9 ± 3.71 x 10-6 m2/s for fabric with one layer with 17%-20% fluctuations from the theory, 27.8 ± 4.5 x 10-6 m2/s for fabric with …
-
Experimental Evaluation of Cooling Effectiveness and Water Conservation in a Poultry House Using Flow Blurring<sup>®</sup> Atomizers
… (e.g., cattle, pork). In this research, an evaporative Flow Blurring® cooling system was considered as an alternative method for cooling in a full scale poultry (e.g., chicken) farm located near Fayetteville, Arkansas, USA. Flow Blurring® is a very efficient pneumatic atomization process, …
-
The mechanics of fiber-based absorbent evaporative cooling (fbaEC) for transport
… methods are needed for use in cooling systems and related applications. In prior research, a new evaporative cooling system model using absorbent fabric wrapping in curtain structure on a scaffold for short-term transport and storage was built in a laboratory scale, and a series …
-
Production, physiological, and hormonal responses of Holstein and Brown Swiss heat-stressed dairy cows to two different cooling systems
To evaluate the effect of two different cooling systems on production, physiological, and hormonal responses, 37 Holstein and 26 Brown Swiss dairy cows were allotted to three treatments. A control group of cows had access to only shade (C). A second group was cooled with spray and fan (S/F) and the …
-
Evaluating and Miniziming Water Use by Greenhouse Evaporative Cooling Systems in a Semi-Arid Climate
… water use, but the study of water use by evaporative cooling has been limited.This project investigated water use by two evaporative cooling systems: pad-and-fan and high-pressure-fog with fan ventilation. All studies were performed in a double-layer polyethylene film-covered greenhouse …
-
Computational fluid dynamics modeling of thermal parameters and airflows and design improvement of naturally ventilated swine facilities in tropical climates
… simulation of the application of a ventilation system associated with an evaporative cooling system. It was verified that, with this study, it was possible to validate the modeling conducted via CFD, observing statistically acceptable values of the modeled parameters, thermaland air flow, in …