Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 188 for “"excitation source"”.

  1. Effects of the geometric modifications on the shear layer excitation source in co-axial side branches

    … cavities, spotlighting the efficacy of the sound source model as a reliable semi-empirical modeling methodology. The focus is on how the downstream acoustic boundary conditions, when varied, markedly alter the acoustic field and the aeroacoustic sound source within deep co-axial cavities. …

    uoit Repository record for Effects of the geometric modifications on the shear layer excitation source in co-axial side branches (opens in a new tab)

  2. Evaluation of the theta pinch as a sampling and excitation source for elemental analysis of solid refractory materials

    … to assess its effectiveness as a sampling and excitation source for elemental analysis of refractory solids. Previous work demonstrated the ability of the discharge to produce spectra suitable for qualitative analysis, but quantitation could not be demonstrated due to insufficient and …

    uiuc Repository record for Evaluation of the theta pinch as a sampling and excitation source for elemental analysis of solid refractory materials (opens in a new tab)

  3. Integrated system damping and isolation of a three dimensional structure

    … deals with an integrated system damping and excitation source isolation scheme of a three dimensional structure. Use of a validated finite element model of the system to predict system dynamic behavior proved to be an effective method in the design of the constrained viscoelastic layered …

    nps Repository record for Integrated system damping and isolation of a three dimensional structure (opens in a new tab)

  4. X-ray diffraction and raman spectroscopy of pulsed light irradiated nanocrystalline silicon

    … samples, is determined using two different Raman excitation sources, 442 and 633 nm. Through a process of peak decomposition, the crystalline volume fraction is determined corresponding to each sample and each Raman excitation source. Five key observations are made from this analysis. First, it is …

    ubc Repository record for X-ray diffraction and raman spectroscopy of pulsed light irradiated nanocrystalline silicon (opens in a new tab) Download PDF for X-ray diffraction and raman spectroscopy of pulsed light irradiated nanocrystalline silicon (opens in a new tab)

  5. Spectrally resolved fluorescence microscopy and its applications for single molecule characterization

    … producing fluorescence when illuminated with the excitation source of the system. In the following thesis I describe my work combining spectral resolution with a fluorescence microscope by developing a hyperspectral prism-type total internal reflection fluorescence microscope. The microscope has a …

    colo-mines Repository record for Spectrally resolved fluorescence microscopy and its applications for single molecule characterization (opens in a new tab)

  6. An Instrument for Determination of the Polarization of Fluorescence

    … of an ellipsoidal mirror positioned between the excitation source and the phototube fluorescence signal receiver. In addition, the excitation source, a 45 watt tungsten-iodide light was electronically regulated to control the intensity. Two types of determinations were made to verify the …

    portland-state Repository record for An Instrument for Determination of the Polarization of Fluorescence (opens in a new tab)

  7. The evaluation of a low powered microwave induced plasma as an atom cell for atomic spectrometry

    … with the introduction of more efficient plasma excitation sources. In this thesis the use of one such plasma excitation source, the microwave induced plasma is evaluated as an atom cell for atomic spectrometry. The modes of spectrometry evaluated are atomic emission and atomic fluoresence. …

    vt Repository record for The evaluation of a low powered microwave induced plasma as an atom cell for atomic spectrometry (opens in a new tab)

  8. Microwave Interferometric Measurements of Electron Density in Laser-Generated Plasma Channels

    … pulse duration resulted in a $\delta$-function excitation source, allowing the subsequent plasma decay to be explored without further excitation of the gas and without deconvolving the excitation source profile from the electron density decay data. The temporal resolution of the interferometer …

    uiuc Repository record for Microwave Interferometric Measurements of Electron Density in Laser-Generated Plasma Channels (opens in a new tab)

  9. Development of a short backfire antenna and a passive microwave radiometer prototype for sea ice monitoring

    … fabricated, and tested as an alternative excitation source instead of a waveguide. Parametric studies were conducted on the stand-alone patch antenna to determine the optimal dimensions of the slots to achieve a wide bandwidth. Next, the Pi-slot patch was integrated into the SBF cavity and …

    manitoba Repository record for Development of a short backfire antenna and a passive microwave radiometer prototype for sea ice monitoring (opens in a new tab)

  10. Radiative lifetime of the A¹π state and the transition moment variation of the fourth positive band system of carbon monoxide

    … has been measured using a pulsed invertron excitation source and delayed coincidence measurement technique on the fourth positive system. Eighteen bands, originating from the upper states v' = 0 to 5, were examined at pressures between 500 and 50 microns, with no pressure dependence noted. …

    must-thes Repository record for Radiative lifetime of the A¹π state and the transition moment variation of the fourth positive band system of carbon monoxide (opens in a new tab)

  11. Nonlinear Ultrafast Excitation and Two-Dimensional Terahertz Spectroscopy of Solids

    … curve in lithium niobate. Customizing the excitation source in ultrafast measurements can excite phonon modes to large amplitudes, allowing the experimental exploration of the Potential Energy Surface in solids. However, stronger pump fluences and bigger signal isn't always the answer in …

    byu Repository record for Nonlinear Ultrafast Excitation and Two-Dimensional Terahertz Spectroscopy of Solids (opens in a new tab) Download PDF for Nonlinear Ultrafast Excitation and Two-Dimensional Terahertz Spectroscopy of Solids (opens in a new tab)

  12. Detection of carbon using microwave excited photoacoustic spectroscopy

    … amounts of carbon. Utilizing microwaves as an excitation source allowed measurements to be made with non-homogenous particle diameter due to the avoidance of Mie scattering. The device was able to detect carbon concentrations effectively from 1 to 43% carbon in various fly ashes.

    iastate Repository record for Detection of carbon using microwave excited photoacoustic spectroscopy (opens in a new tab)

  13. Fluorescence detection of DNA-ethidium complexes in the diffusion layer of a modified electrode

    … electrode potential, (iii) distance of the excitation source from the electrode surface, (iv) electrolysis time, and (v) laser power. Although various ratios of EtTCNQ to carbon proved acceptable for data collection, a 1:20 ratio enabled complex measurement over 6 orders of magnitude of DNA …

    ut-knoxville Repository record for Fluorescence detection of DNA-ethidium complexes in the diffusion layer of a modified electrode (opens in a new tab)

  14. Development of Solid Sampling Modalities for the Liquid-Sampling Atmospheric Pressure Glow Discharge Microplasma

    Fast pretreatment of samples, low resource consumption, and high analytical throughput makes direct solid sampling techniques an attractive choice for a wide range of applications. Currently there are a plethora of analytical techniques capable of solid sampling. However, no commercial technique is …

    clemson Repository record for Development of Solid Sampling Modalities for the Liquid-Sampling Atmospheric Pressure Glow Discharge Microplasma (opens in a new tab)

  15. The collisional de-excitation of neon at various pressures.

    … 3664. 1A line in Neon II to obtain collisional deexcitation cross sections, a,, and de-excitation reaction rates, K... d 1 However, due to a series of problems with the Van De Graaff accelerator in the proton configuration no reproducible data was obtained. The majority of the time was thus spent …

    nps Repository record for The collisional de-excitation of neon at various pressures. (opens in a new tab)

  16. Strain dependent damping characteristics of a high damping manganese-copper alloy

    … treatments. Pure random and sinusoidal sweep excitations are used as an excitation source in the frequency range of 20 to 500 Hz. Miniature acceleromcters and strain gages were mounted on the specimens to obtain both input excitation and output responses. The results of the investigation are …

    nps Repository record for Strain dependent damping characteristics of a high damping manganese-copper alloy (opens in a new tab)

  17. Remote detection of oil under ice using fluorescence

    … The radiation from a nitrogen laser, used as an excitation source, goes through the ice and irradiates a layer of oil under the ice. The oil fluorescence , which emits radiations in the range of about 5 nm, can pass back through the ice and be detected. Once the prominence of sea ice fluorescence …

    rice Repository record for Remote detection of oil under ice using fluorescence (opens in a new tab)

  18. Fourier Transform Raman Spectroscopy for Process Control in the Petroleum Industry

    … was the absence of a high intensity and stable excitation source. This problem has been overcome with the advent of lasers. Another limitation was the presence of fluorescence in hydrocarbon fuels when excited by visible lasers. However, the development of Fourier-transform Raman spectrometers …

    odu Repository record for Fourier Transform Raman Spectroscopy for Process Control in the Petroleum Industry (opens in a new tab)

  19. LINEAR AND NONLINEAR FLUORESCENCE LIFETIME IMAGING FOR BIOSENSING APPLICATIONS

    … techniques, based on both linear and non-linear excitation, have been widely used in biosensing application. Among fluorescence techniques, Fluorescence Lifetime Imaging (FLIM) has gained increased importance because of their robust and versatile feature. FLIM is a technique to visualize the …

    purdue-thes Repository record for LINEAR AND NONLINEAR FLUORESCENCE LIFETIME IMAGING FOR BIOSENSING APPLICATIONS (opens in a new tab)

Page 1 of 10