Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"expansion devices"”.

  1. Investigation of finger plate expansion devices behavior

    … AT AUTHOR'S REQUEST.] Finger plate expansion devices are frequently used to account for medium and large expansive or contractive movements and reasonable rotations of two bridge deck slabs. Under high traffic volume, these expansion devices experience some premature damage that …

    missouri Repository record for Investigation of finger plate expansion devices behavior (opens in a new tab)

  2. Improved design of highway bridge fingerplate expansion devices

    Fingerplate expansion joints are used in highway bridges to account for large movements and rotations of two bridge deck slabs. These joints experience may premature failure that affects the structural integrity of the bridge superstructure. The main reason for early deterioration of fingerplates …

    missouri Repository record for Improved design of highway bridge fingerplate expansion devices (opens in a new tab)

  3. Evaluation of finger plate and flat plate expansion devices

    … of MoDOT finger plate and flat plate expansion devices under high traffic volumes and use that information to design new Load and Resistance Factor Design (LRFD) finger plate and flat plate expansion devices that are intended to last 40 years or more with minimal maintenance. In …

    missouri Repository record for Evaluation of finger plate and flat plate expansion devices (opens in a new tab)

  4. The comparison of different rapid maxillary expansion devices from periodontal tissue health and root resorption perspectives

    INTRODUCTION: Utilization of rapid maxillary expansion (RME) is common for the correction of sagittal discrepancies in orthodontic treatment. RME appliances will transmit a compressive force to the periodontal support structures. This resultant force can lead to resorption of the dento-alveolar …

    bu Repository record for The comparison of different rapid maxillary expansion devices from periodontal tissue health and root resorption perspectives (opens in a new tab)

  5. Adiabatic Developing Two-Phase Refrigerant Flow in Manifolds of Heat Exchangers

    … nozzles are first time applied as the expansion devices at the inlet of the manifold in order to generate mist homogenous flow, which in this study is proven to contribute to uniform distribution.

    uiuc Repository record for Adiabatic Developing Two-Phase Refrigerant Flow in Manifolds of Heat Exchangers (opens in a new tab)

  6. Effects of restrained thermal movement in a continuous, prestressed concrete bridge without interior expansion joints

    … effects, the AASHTO Specifications call for expansion devices to be taken into consideration in design. In recent years, the Tennessee Department of Transportation has taken the lead in the omission or reduction in the number of expansion joints in designing bridges for temperature effects. …

    utk-theses Repository record for Effects of restrained thermal movement in a continuous, prestressed concrete bridge without interior expansion joints (opens in a new tab)

  7. Thermal Microactuators for Microelectromechanical Systems (MEMS)

    … of the groups used the geometrically constrained expansion of various segments to produce their deflection. The first group, Thermal Expansion Devices (TEDs), produced a rotational displacement and had deflections up to 20 µm. The second group, Bi-directional Thermal Expansion Devices (Bi-TEDs) …

    byu Repository record for Thermal Microactuators for Microelectromechanical Systems (MEMS) (opens in a new tab) Download PDF for Thermal Microactuators for Microelectromechanical Systems (MEMS) (opens in a new tab)

  8. A Refrigerant Expansion Control Device Fabricated Through Nickel Deposition Within SU8 Micromolds

    Control of refrigerant expansion offers improved system efficiency and reduced noise among other benefits. The cost of traditional active expansion devices, however, has limited their use to large HVAC&R systems. The design, fabrication and testing of a thermopneumatic microfabricated valve for …

    maryland Repository record for A Refrigerant Expansion Control Device Fabricated Through Nickel Deposition Within SU8 Micromolds (opens in a new tab)

  9. Development and Testing of a Prototype Pilot Expansion Valve for Vapor Compression Systems

    … This thesis proposes a prototype pilot expansion device. Preliminary results have shown that this prototype expansion valve outperforms most of the expansion devices currently being used in HVACR applications. Valve hunting and superheat control are very important elements in the …

    tamu Repository record for Development and Testing of a Prototype Pilot Expansion Valve for Vapor Compression Systems (opens in a new tab)

  10. Análise do desempenho de um refrigerador doméstico funcionando com uma válvula de expansão micrométrica

    … consumption of Brazilian homes. The use of these devices with low energy efficiency contributes to increase the energy consumption. The energy efficiency of a refrigerator is a function of the interaction between the coolant fluid and the components of the thermodynamic cycle. Changes in load …

    brazil-ufrn Repository record for Análise do desempenho de um refrigerador doméstico funcionando com uma válvula de expansão micrométrica (opens in a new tab)

  11. The Effects of Corticotomies on Frontonasal Suture Expansion and Bone Modeling in Mature Rabbits

    … resistance of surrounding articulations during expansion in mature rabbits. Nine adult female New Zealand White (NZW) rabbits, 8 to 9 months old, had miniscrew implant (MSI) supported expansion devices with 150 g open-coil nickel-titanium springs placed bilaterally across the frontonasal …

    tamu Repository record for The Effects of Corticotomies on Frontonasal Suture Expansion and Bone Modeling in Mature Rabbits (opens in a new tab)

  12. Quasi-one-dimensional numerical analysis of choked two-phase flashing flow through millitubes

    Small-diameter tubes are utilized widely as expansion devices in refrigeration systems. Performance of these tubes is reliant upon critical flashing of the two-phase flow that controls the mass flow rate of the refrigeration system, resulting in a steep reduction in pressure and temperature. Due to …

    wichita-thes Repository record for Quasi-one-dimensional numerical analysis of choked two-phase flashing flow through millitubes (opens in a new tab)

  13. The Effect of Mandibular Distraction Osteogenesis On Condylar Rotation in Rabbits

    … to the bony segments. After a brief latency, the expansion devices were activated Imm/day. Expansion continued for 10 days to a maximum of 10 mm. The rabbits had submentovertex radiographs taken at each activation interval. The films were traced, measured and compared for changes in mandibular …

    loma-linda Repository record for The Effect of Mandibular Distraction Osteogenesis On Condylar Rotation in Rabbits (opens in a new tab)

  14. Klinische Ergebnisse nach Transpalatinaldistraktion

    … den Indikationsbereich für skelettal verankerte Expansionsgeräte präzisieren zu können, da es bisher keine einheitliche Empfehlung zur Differentialindikation von dental und skelettal verankerten Expansionsapparaturen zur Korrektur des transversalen maxillären Defizits gibt. Dazu wurden neben den …

    fu-berlin Repository record for Klinische Ergebnisse nach Transpalatinaldistraktion (opens in a new tab)

  15. Development of a static shaft Wankel expander for small-scale applications

    … thesis looks at the development of a Wankel gas expansion device for use in gas liquefaction or ORC systems. It starts with an extensive literature review into LAES and ORC systems. In which literature shows a clear need for the development of both gas liquefaction systems and small-scale, …

    birmingham Download PDF for Development of a static shaft Wankel expander for small-scale applications (opens in a new tab)

  16. Long-Term stability of the correction of the unilateral posterior crossbite

    … of patients treated either with rapid maxillary expansion (RME) or with slow expansion devices in the early (mean age: 7.2 years) or in the late mixed dentition (mean age: 9.9 years).<br>One hundred patients were selected from the files of the Department of Orthodontics, School of …

    freiburg-diss Repository record for Long-Term stability of the correction of the unilateral posterior crossbite (opens in a new tab)

  17. A study on the characteristics of the flow inside a thermostatic expansion valve

    Thermostatic expansion valves (TEV) and electronic expansion valves (EEV) are expansion devices commonly used in air-conditioning system which involves the spray and atomization process of the refrigerant. Most previous studies focused on the macro-features of the expansion valve, such as the …

    uiuc Repository record for A study on the characteristics of the flow inside a thermostatic expansion valve (opens in a new tab)

  18. Design and Development of a Modified Revolving Vane Expander for the Implementation in Micro-ORC Systems

    … However, only a few have been studied as expansion devices for micro and small ORC systems. This study aims to design and develop a modified revolving vane expander (M-RVE) and investigate its performance in a micro-scale ORC system for waste heat recovery application for the first time. …

    auckland-ms Repository record for Design and Development of a Modified Revolving Vane Expander for the Implementation in Micro-ORC Systems (opens in a new tab)