Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 32 for “"extended wear"”

  1. Safety and efficacy of antimicrobial contact lenses during extended wear

    … contact lenses in reducing CIEs during extended human wear was unknown. To address this, a prospective, contralateral, double-masked, randomised, controlled clinical trial with extended lens wear was conducted. During this, subjects wore the bi-weekly extended wear lenses for three …

    unsw Repository record for Safety and efficacy of antimicrobial contact lenses during extended wear (opens in a new tab)

  2. Synthesis and Formulation of Novel Polymers for the Design of Extended Wear Contact Lens Materials and Surfaces

    Controlled free radical polymerization techniques have been employed for the synthesis of polymers for contact lens application. Diblock polyampholyte copolymer brushes of Si/SiO2//poly(acrylic acid-block-2(4)-vinyl pyridine) were synthesized by atom transfer radical polymerization (ATRP) using a …

    ohiolink Repository record for Synthesis and Formulation of Novel Polymers for the Design of Extended Wear Contact Lens Materials and Surfaces (opens in a new tab)

  3. Evaluation of Strategies for Reducing The Incidence of Adverse Events during Extended Wear of Silicone Hydrogel Contact Lenses

    … bacterial contamination of contact lenses during wear remains a problem. Rare but sight-threatening contact lens related corneal infection can also occur. Previous studies have shown that overnight lens wear in the same lens results in increased risk of corneal infection and contamination of the …

    unsw Repository record for Evaluation of Strategies for Reducing The Incidence of Adverse Events during Extended Wear of Silicone Hydrogel Contact Lenses (opens in a new tab)

  4. Electrocardiogram Signal Quality Comparison Between A Dry Electrode and A Standard Wet Electrode over a Period of Extended Wear

    … (DE) over a 96 hour period of continuous wear. Assessments were made within electrode types, comparing potential signal deterioration within the electrode over time, and also between the two electrode types, comparing SNR over time. </p><p> Twenty healthy adult volunteers completed the …

    ohiolink Repository record for Electrocardiogram Signal Quality Comparison Between A Dry Electrode and A Standard Wet Electrode over a Period of Extended Wear (opens in a new tab)

  5. Some Aspects of the Design and Ocular Response to Synthetic Hydrogel Contact Lenses Intended for Continuous Usage

    … constraints on the design of continual (extended) wear contact lenses were reviewed and the theoretical potential of Sauflon T.M. 85, as a continual (extended) wear contact lens was examined. A self-recording, topographic corneal pachometer was constructed and some physiological …

    aston Repository record for Some Aspects of the Design and Ocular Response to Synthetic Hydrogel Contact Lenses Intended for Continuous Usage (opens in a new tab)

  6. ΦΑΚΟΙ ΣΥΝΕΧΟΥΣ ΧΡΗΣΕΩΣ ΣΕ ΜΕΤΕΓΧΕΙΡΗΤΙΚΗ ΑΦΑΚΙΑ

    … STUDY DESCRIBES RESULTS OBTAINED FROM THE USE OF EXTENDED WEAR CONTACT LENSES IN APHAKIC PATIENTS OF THE EPIRUS AREA, 120 PATIENTS WITH EXTENDED WEAR CONTACT LENSES HAVE BEEN EXAMINED FOR A PERIOD OF 3 TO 40 MONTHS.

    greece Repository record for ΦΑΚΟΙ ΣΥΝΕΧΟΥΣ ΧΡΗΣΕΩΣ ΣΕ ΜΕΤΕΓΧΕΙΡΗΤΙΚΗ ΑΦΑΚΙΑ (opens in a new tab)

  7. Refractive error shift with continuous use (Rescu) lenses

    … shown to decrease or reverse when hydrogel lens wearers switch to 30 night and day silicone hydrogel lens wear. To assess the mechanisms contributing to changes in refractive error associated with the refitting of extended wear hydrogel contact lens users with 30-night continuous use silicone …

    ohiolink Repository record for Refractive error shift with continuous use (Rescu) lenses (opens in a new tab)

  8. Matrix metalloproteinase-9 in contact lens-related corneal erosions

    … and can lead to discontinuation of contact lens wear. Understanding their aetiology would assist in managing this important adverse event. In non-contact lens wearers, a collagen degrading enzyme known as matrix metalloproteinase-9 (MMP-9) has been found to be upregulated in the corneas of those …

    unsw Repository record for Matrix metalloproteinase-9 in contact lens-related corneal erosions (opens in a new tab)

  9. Some clinical aspects of the eye in extended contact lens wear

    The limbal vascular response to extended contact lens wear was examined in a group comparative study initially intended to last eighteen months. After six months all patients wearing contact lenses had presented with micro-epithelial cysts. This unanticipated occurrence of the …

    aston Repository record for Some clinical aspects of the eye in extended contact lens wear (opens in a new tab)

  10. The incidence of and risk factors for contact lens related microbial keratitis in Australia and New Zealand

    … blinding complication of contact lens wear. To further understand and reduce the risk of this disease, incidence rates and risk factors have been estimated in numerous studies. Since these studies were conducted, new lens types have been introduced designed to reduce the risk of …

    unsw Repository record for The incidence of and risk factors for contact lens related microbial keratitis in Australia and New Zealand (opens in a new tab)

  11. Some of the Corneal Effects Produced by Wearing Hydrogel Contact Lenses Soaked in a Non-Isotonic Saline

    The corneal response to daily and extended wear hydrogel contact lenses was evaluated when the lenses were soaked in non-isotonic solutions varying from 0.7 to 1.2 percent. The naturally occuring diurnal variations of the cornea were examined to discover what effect they may have on contact lens …

    aston Repository record for Some of the Corneal Effects Produced by Wearing Hydrogel Contact Lenses Soaked in a Non-Isotonic Saline (opens in a new tab)

  12. Risk Factors for Contact Lens Induced Papillary Conjunctivitis Associated with Silicone Hydrogel Contact Lens Wear

    … increased use of silicone hydrogel lenses for extended wear there has been an increase in inflammatory reactions in the eye, including CLPC. The changes that occur in the eye when using an extended wear lens might include: tear stagnation, localized pressure, and a closed eye environment …

    ohiolink Repository record for Risk Factors for Contact Lens Induced Papillary Conjunctivitis Associated with Silicone Hydrogel Contact Lens Wear (opens in a new tab)

  13. Effect of antibacterial contact lenses on inflammatory responses in a guinea pig model

    … responses of the eye associated with extended wear of soft contact lenses. Bacterial colonization of contact lenses with Gram-negative bacteria such as Pseudomonas aeruginosa is an important risk factor for the development of these adverse responses. Strategies that control the …

    unsw Repository record for Effect of antibacterial contact lenses on inflammatory responses in a guinea pig model (opens in a new tab)

  14. A characterization of dryness symptoms with Silicone Hydrogel contact lenses

    … is to characterize dryness symptoms of patients wearing silicone hydrogel contact lenses. Previous studies and clinical experience has shown that a higher percentage of patients experience less dryness with monthly continuous wear of silicone hydrogel contact lenses than six-night extended wear …

    ohiolink Repository record for A characterization of dryness symptoms with Silicone Hydrogel contact lenses (opens in a new tab)

  15. The effect of objectively measured sitting time during work and leisure on back function and perceived low back pain: a feasibility study

    … primarily assessed the feasibility of using wearable sensors to objectively monitor sitting time and spinal posture in real-world contexts. A secondary exploratory aim examined short-term exposure–response relationships. Methods: Thirty office workers were included in this study. All …

    newfoundland Repository record for The effect of objectively measured sitting time during work and leisure on back function and perceived low back pain: a feasibility study (opens in a new tab)

  16. Some Aspects of Corneal Physiology in extended Contact Lens Wear

    … in vivo cornea during periods of contact lens wear are manifest in many different ways. The aim of the experimental work described in this thesis was to examine: (1) Apparent in vivo human corneal oxygen uptake rates. (2) Apparent corneal endothelial cell density. An existing apparatus for the …

    aston Repository record for Some Aspects of Corneal Physiology in extended Contact Lens Wear (opens in a new tab)

Page 1 of 2