Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 75 for “"extensometer"”.

  1. A temperature-compensated induction extensometer

    … testing of a temperature-compensated induction extensometer was undertaken. Both the linear dimensions and the electrical properties of materials depend upon the temperature. The extensometer measures changes produced by the displacement of a coil relative to a conductor. If the conductor is …

    utk-theses Repository record for A temperature-compensated induction extensometer (opens in a new tab)

  2. Development and Validation of a Single-Camera Video Extensometer

    … properties of materials and constructs. A video extensometer is a common measurement device in mechanical testing which uses a video camera to track fiducial markers on a specimen. This work presents the development and validation of a custom video extensometer that was assembled from readily …

    queens Repository record for Development and Validation of a Single-Camera Video Extensometer (opens in a new tab)

  3. Hydromechanical Well Testing Using a 3D Fiber Optic Extensometer

    Some fractured rock formations hold important resources, such as water, hydrocarbons or heat, whereas others are good candidates for waste disposal. Hydromechanical well tests have been developed to improve characterization of formation properties and parameter distributions by measuring …

    clemson Repository record for Hydromechanical Well Testing Using a 3D Fiber Optic Extensometer (opens in a new tab)

  4. Development of a Variable Extensometer Method for Measuring Ductility Scaling Parameters

    Ductility is the measure of how much a material can stretch before separation. It is usually measured in percent elongation, which is the amount a material stretches divided by its original length before stretching. This is an important property to understand for both the design for performance and …

    utahstate Repository record for Development of a Variable Extensometer Method for Measuring Ductility Scaling Parameters (opens in a new tab)

  5. Development of a Wireless Borehole Extensometer for Monitoring Convergence in Underground Mines

    An extensometer has been developed to continuously monitor roof extension in underground mines. The extensometer is designed to be installed in the MSHA-mandated test holes in the roof and measures the displacement between an anchorage point at the top of the borehole and the hole in the roof of …

    vt Repository record for Development of a Wireless Borehole Extensometer for Monitoring Convergence in Underground Mines (opens in a new tab)

  6. Spatial and Temporal Variability in Vertical Deformation in Willowbend, TX Derived from Long-Term GPS and Extensometer Observations

    … GPS stations (2000-2013) and one USGS borehole extensometer (1980-2012). The Willowbend neighborhood is located southwest of downtown Houston, near an area of recent and rapid subsidence (the Jersey Village subsidence bowl). GPS positions are generated in reference to a global reference frame, …

    houston Repository record for Spatial and Temporal Variability in Vertical Deformation in Willowbend, TX Derived from Long-Term GPS and Extensometer Observations (opens in a new tab)

  7. Construction and statistical analysis of an industry wide ground control database of mechanical roof extensometer data from underground coal mine gateroads

    The abundance of quantitative roof convergence measurements systematically recorded in Australian mines is distinctly different to all other major coal-producing countries, including the USA, South Africa, and China. The literature review identified that no industry-wide research using this data …

    unsw Repository record for Construction and statistical analysis of an industry wide ground control database of mechanical roof extensometer data from underground coal mine gateroads (opens in a new tab)

  8. Groundwater Withdrawal and Aquifer Compaction: A Case Study in Addicks, Texas

    … the continuous measurements of one USGS borehole extensometer (1975-2012) and two Subsidence District GPS stations (1996-2012). The Addicks Facility is located in west Houston, near an area of recent and rapid subsidence. GPS positions are generated within the IGS08 Reference Frame using the …

    houston Repository record for Groundwater Withdrawal and Aquifer Compaction: A Case Study in Addicks, Texas (opens in a new tab)

  9. Comparative Study of Experimental and FEA Strain Data for CNT-Coated Fiberglass Sensors, Extensometers, and Metal Foil Strain Gauges

    … with a typical gauge factor around 2. Extensometers provide highly sensitive strain measurements with the disadvantage of a bulky form factor. With advanced materials such as carbon nanotubes, it is possible to manufacture a sensor with the sensitivity closer to that of an extensometer …

    calpoly Repository record for Comparative Study of Experimental and FEA Strain Data for CNT-Coated Fiberglass Sensors, Extensometers, and Metal Foil Strain Gauges (opens in a new tab)

  10. Investigate the use of strain gauge technology for the determination of the mechanical characteristics of polypropylene ankle-foot orthoses

    … patient’s activity. Initially PP samples with an extensometer attached on them were tested following as far as possible the British Standard BS 527-1, with two different tensile test protocols on an Instron machine with the aim of investigating the material’s viscoelastic nature. Strain gauged …

    strathclyde Repository record for Investigate the use of strain gauge technology for the determination of the mechanical characteristics of polypropylene ankle-foot orthoses (opens in a new tab)

  11. Methods for Evaluating Aquifer-System Parameters from a Cumulative Compaction Record

    … and water-level data were collected from an extensometer and multi-level piezometer at the Lorenzi site in Las Vegas Valley and when graphed yearly, seasonal, and daily signals are observed. Each temporal signal reflects different characteristics of the aquifer-system, including the …

    vt Repository record for Methods for Evaluating Aquifer-System Parameters from a Cumulative Compaction Record (opens in a new tab)

  12. Land Subsidence and Rebound in the Houston Ship Channel and Downtown Houston (2000-2018)

    … Global Positioning System (GPS) and borehole extensometer observations indicate that land rebound began in the region starting from 2001-2004 and that current rates of uplift range from ~0.6-4.0 mm/year. Borehole extensometer observations and seasonal modeling of GPS displacement and …

    houston Repository record for Land Subsidence and Rebound in the Houston Ship Channel and Downtown Houston (2000-2018) (opens in a new tab)

  13. Evaluation and Optimisation of the Small Ring Test and its Amalgamation with the Small Punch Test

    … specimen locations, suggesting the design of an extensometer for the SRT. A 30° claw-like extensometer, gripping the ring at 30° points on either side of the horizontal axis, is found to be optimal.<br></br><br></br> This thesis also studies the concurrent use of SRT and SPT, where SPT specimens …

    the-open-u Download file for Evaluation and Optimisation of the Small Ring Test and its Amalgamation with the Small Punch Test (opens in a new tab)

  14. Experimental Investigation of Mechanical Behaviour of Hybrid Bolted/Bonded Joints for Aircraft

    … The DIC technique is verified with the axial extensometer by measuring displacement and strain fields from the simple aluminum test coupon. Additionally, the DIC technique with the instrumented bolt, which is the classic measurement technique to obtain shear load in the bolt, is examined in …

    carleton Repository record for Experimental Investigation of Mechanical Behaviour of Hybrid Bolted/Bonded Joints for Aircraft (opens in a new tab)

  15. Skin Flap Surgery - Non-Invasive in Vivo Methodology to Predict Skin Flap Shrinkage

    … It involves the use of a novel custom designed extensometer to measure the biomechanical properties of skin, followed by data analysis to estimate the flap shrinkage. In validation experiments performed on pigs, this method has been shown to produce results with an average absolute error of 6.0% …

    nus Repository record for Skin Flap Surgery - Non-Invasive in Vivo Methodology to Predict Skin Flap Shrinkage (opens in a new tab) Download file for Skin Flap Surgery - Non-Invasive in Vivo Methodology to Predict Skin Flap Shrinkage (opens in a new tab)

  16. MEASUREMENT AND ANALYSIS OF HYDROMECHANICAL EFFECTS IN FRACTURED ROCK

    … was the development of two removable borehole extensometers that enable small axial displacements to be measured during hydraulic well tests. The extensometers consist of four major components: 1.) a pair of anchors; 2.) a displacement transducer 3.) a registration system, and; 4.) a …

    clemson Repository record for MEASUREMENT AND ANALYSIS OF HYDROMECHANICAL EFFECTS IN FRACTURED ROCK (opens in a new tab)

  17. Investigation of Composite Materials Using Digital Volume Correlation

    … measurement technique such as strain gauge and extensometer provide limited information. Therefore, to understand the internal structure under loading conditions, there is a need for full field internal displacement and strain field. Digital Volume Correlation (DVC) is a measurement technique …

    york Repository record for Investigation of Composite Materials Using Digital Volume Correlation (opens in a new tab)

  18. Constitutive Property Testing and Reliability Assessment of Lead-Free Solder Joint

    … are subsequently captured by a high-resolution extensometer. The extension unit allowed measurement of shear deformations without compensating machine and grip compliance. The proposed test configuration is utilized to characterize the constitutive properties of lead-free solder. Experimental …

    maryland Repository record for Constitutive Property Testing and Reliability Assessment of Lead-Free Solder Joint (opens in a new tab)

  19. Monitoring and Modeling Long-term Environmental Influences on a Shallow Excavation Using Machine Learning: Case Study of Tomb TT95 in the Theban Necropolis, Luxor, Egypt

    … Luxor, Egypt. Using two orthogonally placed extensometers, relative displacements of the pillar were measured alongside temperature and humidity. Findings indicate that pillar displacements correlate with seasonal temperature changes, showing a 0.02 mm/year drift. Data-driven CNN models were …

    york Repository record for Monitoring and Modeling Long-term Environmental Influences on a Shallow Excavation Using Machine Learning: Case Study of Tomb TT95 in the Theban Necropolis, Luxor, Egypt (opens in a new tab)

Page 1 of 4